Danfoss PL35F Data sheet

PL35F Standard Compressor R134a 220-240V 50Hz
General
Code number 101G0202
Approvals EN 60335-2-34 with Annex AA
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -25 to 0
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 60 (70)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S
38°C S
43°C
Remarks on application:
Motor
Motor type RSIR
LRA (rated after 4 sec. UL984), HST | LST A 1.7
Cut in Current, HST | LST A 5.6
Resistance, main | start winding (25°C) 52.0 19.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 300
Free gas volume in compressor cm
Weight without electrical equipment kg 4.1
Dimensions
Height mm A 134
Suction connector location/I.D. mm | angle C 6.2 | 41.5°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 45°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 21°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 132
B1 125
B2 73
2.00
150 (polyolester)
830
S = Static cooling normally sufcient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.S2.02 / 520N1349 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling, 2 W PTC consumption incl.
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 31.9 36.0 44.6 60.3 78.9 93.0 101 125
Power cons. in W 50.1 52.0 56.7 64.0 71.7 77.0 79.9 88.1
Current cons. in A 0.50 0.50 0.51 0.53 0.55 0.57 0.58 0.62
COP in W/W 0.64 0.69 0.79 0.94 1.10 1.20 1.25 1.42
ASHRAE LBP 220V, 50Hz, static cooling, 2 W PTC consumption incl.
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 39.8 45.0 55.6 75.0 98.2 116 125 156
Power cons. in W 50.0 52.0 56.6 63.8 71.5 77.0 79.5 87.7
Current cons. in A 0.50 0.50 0.51 0.53 0.55 0.57 0.58 0.62
COP in W/W 0.80 0.86 0.98 1.18 1.37 1.51 1.57 1.78
Accessories for PL35F Figure Code number Test conditions EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 54.4°C
Starting relay 6.3 mm spade connectors a2 Suction gas temperature 32°C 32°C
Start. capacitor 60 µF 6.3 mm spade connectors c Liquid temperature no subcooling 32°C
Cover b 103N0491
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø : 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.S2.02 / 520N1349 June 2012
Loading...