PL30F
Standard Compressor
R134a
100 - 115V 50/60Hz
General
Code number 101G9100
Approvals UL984
Compressors on pallet 150
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °F -13 to 59 -13 to 59
Voltage range V 90 - 127 90 - 127
Max. condensing temperature continuous (short) °F 122 (140) 122 (140)
Max. winding temperature continuous (short) °F 257 (275) 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F S S S S S S
100°F S S S S S S
110°F S S S S S S
Remarks on application: - max ambient temperature at 100V: 100°F
- max ambient temperature at 115V: 110°F
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 6.1 9.5
Cut in Current, HST | LST A 6.1 9.5
Resistance, main | start winding (77°F) Ω 7.6 13.6
Design
Displacement cu.in 0.09
Oil quantity (type) .oz. 5.1 (polyolester)
Maximum refrigerant charge oz. 10.5
Free gas volume in compressor .oz. 28.9
Weight without electrical equipment lbs. 9.5
Dimensions
Height inch A 5.28
Suction connector location, I.D. in. | angle C 0.252-0.259 | 41.5°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 45°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.202-0.205 | 21°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
B 5.20
B1 4.88
B2 2.87
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.J6.22 / 520N1350 1/2

ASHRAE LBP 115V, 60Hz, static cooling, PTC consumption incl.
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 89.1 103 156 221 252 302 399 421 517 584 657 804
Power cons. in W 49.7 50.8 55.2 60.5 63.0 66.3 72.4 74.0 78.5 81.4 84.2 88.9
Current cons. in A 1.07 1.07 1.09 1.11 1.12 1.13 1.16 1.16 1.19 1.20 1.22 1.25
EER in BTU/Wh 1.79 2.03 2.82 3.66 4.01 4.55 5.51 5.72 6.58 7.17 7.79 9.04
ASHRAE HBP 115V, 60Hz, static cooling, PTC consumption incl.
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 79.2 91.6 139 197 224 268 354 375 458 517 581 711
Power cons. in W 49.7 50.8 55.2 60.5 63.0 66.3 72.4 74.0 78.5 81.4 84.2 88.9
Current cons. in A 1.07 1.07 1.09 1.11 1.12 1.13 1.16 1.16 1.19 1.20 1.22 1.25
EER in BTU/Wh 1.59 1.80 2.51 3.25 3.07 4.04 4.89 5.09 5.83 6.35 6.90 7.99
EN 12900 Household (CECOMAF) 115V, 60Hz, static cooling, PTC consumption incl.
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in W 21.0 24.3 36.8 52.3 59.0 71.2 94.2 99.0 122 137 154 189
Power cons. in W 49.7 50.8 55.2 60.5 63.0 66.3 72.4 74.0 78.5 81.4 84.2 88.9
Current cons. in A 1.07 1.07 1.09 1.11 1.12 1.13 1.16 1.16 1.19 1.20 1.22 1.25
COP in W/W 0.42 0.48 0.67 0.86 0.95 1.07 1.30 1.35 1.55 1.69 1.83 2.12
Accessories for PL30F Figure Code number Test conditions
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. 103N0023 Ambient temp.
103N0003 Condensing temp.
a1
Starting relay 1/4 in. spade connect. a2 117U6000 Suction gas temp.
Cover b 103N0492 Liquid temperature
ASHRAE
LBP
130°F
90°F
90°F
90°F
ASHRAE
HBP
130°F
95°F
95°F
115°F
EN 12900/
CECOMAF
131°F
90°F
90°F
131°F
Start. capacitor 80 µF 1/4 in. spade connect. c 117U5015
Cord relief d 103N1010 Mounting accessories Code number
Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5 /8 i n. 118-1918
Snap-on in quantities Ø : 5/ 8 in . 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.J6.22 / 520N1350 June 2012