PL20F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.B8.02)
General
Compressor PL20F
Code number 101G0100
Application
PL20F
101G
Application
Application MBP
Evaporating temperature range °C -25 to 0
Voltage range V/Hz 198 - 254 /50
Motor type RSIR
Max. ambient temperature °C 38
Comp. cooling at ambient temp. 32°C S
38°C S
Design
Displacement cm
Oil quantity cm
Maximum refrigerant charge g 300
Free gas vol. in compressor cm
Weight without electrical equipment kg 3.8
3
3
3
1.41
150
800
Motor
Motor size watt 29
LRA (rated after 4 sec. UL984) LST A 1.2
Cut-in current LST A 5.7
Resistance, main and start winding (25°C) Ω 84.0/19.0
Approvals EN 60335-2-34 with Annex AA
Dimensions
Height mm A 129
B 127
B1 120
B2 73
Suction connector location/I.D. mm C 6.2 ±0.09
Process connector location/I.D. mm D 6.2 ±0.09
Discharge connector location/I.D . mm E 5.0 +0.12/+0.20
Compressors on a pallet pcs. 150
Blue stripe
Approvals
Barcode on
white background
Yellow background
R134a
S = Static cooling normally sufficient
O = Oil cooling
F1= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2= Fan cooling 3.0 m/s necessary
204
170
ø16
D
206
0100
DANFOSS COMPRESSORS
35
C
B1
B2
8241
8270-2
70
100
ø9
E
B
A
60.5
50
127
February 2003 CD.41.B9.02 1
130
46
59
Capacity (EN 12900/CECOMAF) watt
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material.Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
C°\.pmoC52-3.32-02-51-01-5-0
F02LP0.610.914.525.636.949.466.28
Capacity (ASHRAE) watt
C°\.pmoC52-3.32-02-51-01-5-0
F02LP7.914.323.130.543.163.08201
g
b
8224
Power consumption watt
C°\.pmoC52-3.32-02-51-01-5-0
F02LP0.244.344.645.152.753.367.96
Current consumption A
C°\.pmoC52-3.32-02-51-01-5-0
F02LP53.053.063.073.093.014.034.0
COP (EN 12900/CECOMAF) W/W
C°\.pmoC52-3.32-02-51-01-5-0
F02LP83.044.055.017.078.030.191.1
COP (ASHRAE) W/W
C°\.pmoC52-3.32-02-51-01-5-0
F02LP74.045.076.078.070.172.174.1
Test conditions EN 12900/CECOMAF ASHRAE
Condensing temperature 55°C 55°C
Ambient and suction gas temp. 32°C 32°C
Liquid temperature 55°C 32°C
Static cooling, 220V 50Hz,
PTC consumption incl.
Accessories
seciveD.giFF02LP
sedapsmm3.6ecivedgnitratsCTP
1a
sedapsmm8.4
revoCb1940N301
feilerdroCd0101N301
CTProfneercsnoitcetorPg6740N301
seirosseccagnitnuoM
rosserpmocenoroftniojtloB
seititnauqnitniojtloB
seititnauqnino-panS
1100N301
8100N301
7191-811
8191-811
9191-811
Main winding
N
N
Winding protector
d
a1
C
a1
Start winding
L
2 CD.41.B9.02 February 2003