Danfoss PFD10-OD Technical Information

Shown with Deutsch Coils

Proportional Valves Technical Information

Proportional Flow Divider

PFD10-OD

OPERATION

PDF10-OD: Proportional Flow Divider, 10 Size, Normally Open, Divider This is a proportional, compensated, normally open, flow dividing, pre-

engineered HIC. When there is no current applied to the coils, the inlet flow is divided equally between ports A and B. As an example, if inlet flow is 40 LPM, the flow out Ports A and B will divide equally 20 LPM. The performance curve below shows input flow examples of 40, 20 and 10 LPM. Minimum inlet flow is 10 LPM (2.6 GPM). The flow ratio between ports A and B will proportionally vary as current is provided to coils S1 or S2. As current increases to coil S2, the flow to Port B will proportionally increase, while Port A decreases, as shown in the graph. Inversely, as current increases to coil S1, the flow to Port A will proportionally increase, while Port B decreases.

Note that this is not a combiner, the flow only exits Ports A and B. Connect the drain port DR to tank, limiting the pressure on this port to 50 bar (720 psi).

APPLICATIONS

Proportionally divide the input flow between two motors or hydraulic circuits (like HICs). Circuits that can take advantage of this pre-engineered HIC include any function where the motors or the HICs continuously require flow, and you only need to proportionally manage the amount of flow between them. Achieve repeatable, load-

independent flow dividing with the built-in pressure compensator. See performance curve below for compensation capabilities.

Note: For optimal performance, install with the solenoid valve in the horizontal position, reducing the chance for

SPECIFICATIONS

 

 

SCHEMATIC

 

 

 

 

Rated Pressure

230 bar [3335 psi]

 

Maximum Rated Flow

40 l/min

 

 

 

[10.6 US gal/min]

 

Maximum Pressure in

50 bar

 

 

Port DR

[ 720 psi ]

 

 

Minimum Inlet Flow

10 l/min [2.6 US gal/min]

 

Weight including Coil

1.15 kg [2.53 lb]

 

Coil

M16

26 Watts

 

Coil Voltage

12 V

24 V

 

Max. Control Current

1.5 Amp

0.75 Amp

 

 

 

 

 

Hysteresis

< 4%

 

 

 

 

 

THEORETICAL PERFORMANCE

BC332375973113en-000101 • February 2020

PV - 53

Danfoss PFD10-OD Technical Information

Proportional Valves Technical Information

Proportional Flow Divider

PFD10-OD

DIMENSIONS mm [in]

235.3

[9.26]

20mm

4-6 Nm [35-53 lbf * in]

Coil Nut Kit P/N 1740031

 

S2

S1

109

8

 

[4.29]

 

[0.31]

 

n8.5 [0.335]

82

 

 

[3.23]

THRU HOLES 2 PLACES

 

 

 

<![if ! IE]>

<![endif]>98 [3.50] 105 [4.13] APPROX 123 [4.85]

EXAMPLE CIRCUITS

Proportionally dividing

Proportionally dividing

flow between two motors

flow between two hydraulic

 

systems (HICs)

ORDERING INFORMATION

BC332375973113en-000101 • February 2020

PV - 54

Loading...