Danfoss PFD10-OD Technical Information

Proportional Valves Technical Information
Proportional Flow Divider PFD10-OD
OPERATION
APPLICATIONS
Proportionally divide the input flow between two motors or hydraulic circuits (like HICs). Circuits that can take advantage of this pre-engineered HIC include any function where the motors or the HICs continuously require flow, and you only need to proportionally manage the amount of flow between them. Achieve repeatable, load­independent flow dividing with the built-in pressure compensator. See performance curve below for compensation capabilities. Note: For optimal performance, install with the solenoid valve in the horizontal position, reducing the chance for
Shown with Deutsch Coils
SPECIFICATIONS
Rated Pressure 230 bar [3335 psi]
Maximum Rated Flow
Maximum Pressure in Port DR
Minimum Inlet Flow 10 l/min [2.6 US gal/min] Weight including Coil 1.15 kg [2.53 lb] Coil M16 26 Watts Coil Voltage 12 V 24 V Max. Control Current 1.5 Amp 0.75 Amp
Hysteresis < 4%
40 l/min [10.6 US gal/min]
50 bar [ 720 psi ]
THEORETICAL PERFORMANCE
SCHEMATIC
BC332375973113en-000101 • February 2020
PV - 53
DIMENSIONS
235.3
mm [in]
Proportional Valves Technical Information
Proportional Flow Divider PFD10-OD
[9.26]
20mm
4-6 Nm [35-53 lbf * in]
Coil Nut Kit P/N 1740031
S1S2
89
105
[4.13]
[3.50]
[4.85]
APPROX 123
EXAMPLE CIRCUITS
Proportionally dividing flow between two motors
109
[4.29]
n8.5 [0.335]
THRU HOLES 2 PLACES
[0.31]
8
82
[3.23]
Proportionally dividing flow between two hydraulic systems (HICs)
ORDERING INFORMATION
BC332375973113en-000101 • February 2020
Loading...