Danfoss PC12-LPS Technical Information

Logic Elements Technical Information

Pressure Compensator

PC12-LPS

OPERATION

The PC12-PS is a 12-size, load sense, priority, static, pressure compensator. The valve will provide on-demand priority flow to port 2 in the required amount (dependent on the load sense pressure on port 1), allowing the excess flow to go to auxiliary functions through port 4.

APPLICATION

Common applications include steering circuits that require pre-compensated, priority flow to go to the steering system, and the excess flow will go to an auxiliary function, like a fan motor. To obtain dynamic load sensing (priority type pre-comp) add in orifice between ports 2 and 1 in the manifold. This provides faster response and is commonly used in steering to flush out LS line. See Circuit Example.

SPECIFICATION

SCHEMATIC

Rated pressure

210 bar [3045 psi]

2 4

Rated flow at 7 bar

75 l/min

[100 psi]

[20 US gal/min]

 

Weight

0.31 kg [0.68 lb]

 

Cavity

CP12-4

1

 

 

 

 

3

 

 

Theoretical performance

 

 

PERFORMANCE CURVE

 

 

 

 

Pressure drop

 

 

 

psi

bar

33 cSt[154 SUS] hyd.oil@38 C [100° F]

 

 

 

 

 

 

 

 

261

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

218

15

 

 

 

 

 

 

 

 

174

12

 

3 to 4,

 

 

 

 

 

 

131

9

 

2 Blocked

 

 

 

 

 

 

 

 

 

 

 

 

 

87

6

 

 

 

 

 

 

 

 

44

3

 

 

3 to 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

 

 

 

 

 

 

 

 

l/min 0

20

40

60

80

100

 

 

USgal/min 0

5.3

10.7

15.8

21.1

26.4

 

BC332375783111en-000101 • February 2020

 

 

 

 

 

LE - 79

Danfoss PC12-LPS Technical Information

Logic Elements Technical Information

Pressure Compensator

PC12-LPS

DIMENSION

Cross-sectional view

 

mm [in]

 

 

1-1/16 -12 UN

1.25 in.

 

68-75 Nm [50-55 lbf-ft]

1

2

3

4

80.59

 

25.40

[3.17]

 

[1.00]

EXAMPLE CIRCUITS

ORDERING INFORMATION

PC12-LPS-5.5-B-00

Differential Control Pressure

5.5= 5.5 bar [80 psi]

7.0= 7 bar [100 psi]

10.0= 10.0 bar [150 psi]

Housing and ports

Housing Part #

00 = No Housing

No Housing

3B = Al, 1/2 BSP

CP12-4-3B

4B = Al, 3/4 BSP

CP12-4-4B

10S = Al, #10 SAE

CP12-4-10S

12S = Al, #12 SAE

CP12-4-12S

Seals

Seal Kit

B = Buna-N

120262

V = Viton

120263

BC332375783111en-000101 • February 2020

LE - 80