Data Sheet
Hydraulic Steering Unit
OSPD
The OSPD is a dual displacement steering unit, which
assures easy maneuverability of machines of most
sizes.
Each unit in the complete steering range combines
superior performance with the highest standards of
safety, operator comfort and low noise levels.
Due to flexibility in combination of rotary meters,
OSPD can be offered with many different ratios
between emergency steering and normal steering
displacement, ratios between 1:2 and 1:7.
OSPD also can be offered with external shift of
displacement. In this way can be selected between
different displacements to improve comfort and
productivity.
Features
•
The OSPD has 2 rotary meters (gear
wheel sets). In the case of no pump
supply only one rotary meter is active
for emergency steering. In normal
steering situations both rotary meters
are active.
•
With OSPD even heavy vehicles can in
many cases fulfil legislations and be
steered without the emergency steering
pump.
•
Ratio between normal steering
displacement and emergency steering
displacement from factor 2 up to 7.
•
Low steering torque 0.8 to 3.0 N•m [7.08
to 26.55 lbf•in] in normal steering
situations.
•
Low noise.
•
One or several built in valve functions
possible: pressure relief, shock and
suction in L + R, Non-return in P and in
LS.
Applications
•
Larger tractors
•
Combines
•
Backhoe loaders
•
Telescopic handlers
•
Wheel loaders etc.
Comprehensive technical literature online
at powersolutions.danfoss.com
©
Danfoss | April 2016 AI00000256en-US0102 | 1
OSPD program
150-593.12
35 [1.38]
Ø44.4 [1.748]
Ø25.4 [1.000]
38 [1.50]
44 [1.73]
47 [1.85]
max. 87 [3.42]
Ø91 [3.58]
51 [2.01]
2.8 [0.110]
min. 7.1 [0.280]
7 [0.28]
45˚
Ø82.3 [3.240]
Ø81.7 [3.217]
57 [2.24]
85 [3.35]
102 [4.02]
44 [1.73]
29 [1.14]
LS
B
A
L
2
L
1
LS
R
L
T P
L
3
Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumünster, Germany
Phone: +49 4321 871 0
Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222
Danfoss
Power Solutions (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
•
Open center Non-reaction (ON)
•
Open center Reaction (OR and ORM)
•
Load Sensing non-reaction (LS) dynamic
•
Load Sensing Reaction (LSR + LSRM) dynamic
OSPD dimensions
Type
L
1
mm [in]
OSPD 60/185 191 [7.52] 9.1 [0.36] 16.2 [0.64] 7.5 [16.53]
OSPD 60/220 195 [7.68] 9.1 [0.36] 20.8 [0.82] 7.7 [16.98]
OSPD 70/195 190 [7.48] 9.1 [0.36] 16.2 [0.64] 7.5 [16.53]
OSPD 70/230 195 [7.68] 9.1 [0.36] 20.8 [0.82] 7.7 [16.98]
OSPD 100/260 199 [7.83] 13.0 [0.51] 20.8 [0.82] 7.8 [17.20]
OSPD 100/300 204 [8.03] 13.0 [0.51] 26.0 [1.02] 8.0 [17.64]
OSPD 125/285 202 [7.95] 16.2 [0.64] 20.8 [0.82] 7.9 [17.42]
OSPD 125/325 207 [8.15] 16.2 [0.64] 26.0 [1.02] 8.1 [17.86]
OSPD 125/440 222 [8.74] 16.2 [0.64] 40.9 [1.61] 8.7 [19.18]
L
2
mm [in]
L
3
mm [in]
Weight
kg [lb]
OSPD specifications
Displacement
(most common)
Maximum system
pressure/ max P-T
port pressure
Max. back
pressure/ max. Tport pressure
Max. flow, Open
center version
Input torque
Valve functions Check valve for manual steering standard on all
Port options P, T, L, R LS
Neutral pressure
drop, ON/OR
versions
*
For standard neutral spring kit 150-4209
60/185, 60/220, 60/260, 70/195, 70/230, 100/260,
100/300, 125/285, 125/325 and 125/440 cc/rev
210 bar [3045 psi]
40 bar [580 psi]
70 l/min [18.49 US gal/min]
*
0.8 - 3 N•m [7.08-26.55 lbf•in]
versions. Possible pressure relief, shock and suction
valves, check valve in P and in LS (dynamic only)
DIN 3852-2 BSP G 1/2" G 1/4"
ISO 6149-1 M18x1.5 M12x1.5
ISO 11926-1 3/4-16 UNF 7/16-20 UNF
3 bar [43.5 psi] at 20 l/min [5.28 US gal/min] and at
viscosity 21 cSt
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | April 2016 AI00000256en-US0102