Danfoss ORT-01 Data sheet

Datasheet
ORT-01 Electronic Room Thermostat for use with OpenTherm boilers
Features
Dimensions
The ORT-01 is a sophisticated room thermostat which provides modulating control of OpenTherm equipped condensing gas boilers.
The thermostat is fully compliant with the OpenTherm communications protocol including low load regulation and domestic hot water keep hot feature now in common use in many combination boilers.
3
78
86
The thermostat utilises a micro processor which provides the accurate PI control algorithm and manages the bi-directional data communication with the boiler.
User interface is by means of an easy to understand setting dial and a status LED indicator that provides information on boiler output and a common alarm indication which is lit whenever a fault is encountered within the boiler.
Provides full modulation to OpenTherm equipped boilers
Simple to install 2-wire non-polarised low voltage communications
Accurate PI room temperature regulation
Signicantly improves boiler eciency
Dial setting provides easy to understand user interface
85
© Danfoss HS | 09/2015 | 126v04 VDRKJ302
8
42
1
Datasheet ORT-01Electronic Room Thermostat
Technical Performance
Laboratory tests comparing the performance of the ORT-01 OpenTherm room thermostat with that of a traditional electro-mechanical on/o thermostat, clearly show that modulating control gives the best level of comfort, the lowest level of energy consumption and the lowest level of harmful CO2 emissions.
The speed of response of the modulating thermostat is also signicantly faster than it’s on/o counterpart allowing even small changes in room temperature to be communicated to the boiler.
Results from tests made in a controlled laboratory environment, show that savings in the order of 15% are achievable when comparing the control of an OpenTherm boiler controlled by a modulating room thermostat compared to the same boiler being controlled by a traditional mechanical on/o thermostat.
Mechanical On/O Thermostatic Control of OpenTherm boiler
Modulating Thermostatic Control of OpenTherm boiler
2