Danfoss ORT-01 Installation guide

Danfoss Heating
ORT-01
Electronic modulating room thermostat for
OpenTherm appliances
Installation and User Guide
Index
Index
GB
Specification .................................................................................... 3-4
Positioning and installation ............................................................5
Wiring ...............................................................................................6-7
Mounting .............................................................................................8
Locking & Limiting .................................................................................9
NL
Technische Specificaties ............................................................12-13
Positionering / Installatie ............................................................... 14
Bedrading ....................................................................................15-16
Montage ............................................................................................ 17
Blokkeren & Begrenzen ..................................................................... 18
2
Specication
Specication
Code Number 087N774300
Temperature range 8-30°C
Maximum ambient temperature 45°C
Control type P + I
OpenTherm software version 2.3
Domestic hot water keep hot feature
Holiday mode
ID 14 low load control
Thermostat output Data
Construction EN60730-2-9
IP rating IP20
Supply voltage 24V DC from boiler
Wiring, non-polarised 2 wire bus
Control pollution situation Degree 2
Ball hardness test 75°C
Dimensions (mm) 86 high x 85 wide x 42 deep
NLNLGB
Specication
3
Specication
ErP
5
NLNLGB
ERP Class
The products represented within this document are classied according to, and allow completion of, the Energy Related Product (ErP) Directive System Package che and the ErP system data label. ErP Labelling obligation is applicable from 26th September 2015.
Specication
ErP Class Product Function and ErP Description
Modulating Room Thermostat, for use with modulating heaters
An electronic room thermostat that varies the ow temperature of the water leaving
V
the heater dependent upon measured room temperature deviation from room thermostat set point. Control is achieved by modulating the output of the heater.
4
Product
Class
Additional
eciency
gain
3%
Positioning and Installation
ORT-01
(5FT)
NLNLGB
Positioning and Installation
5
NLNLGB
Wiring
1.
Wiring
For surface mounted wiring, cutouts are provided on the backplate to enable correct positioning of the cable.
6
2.
For recessed wiring, cabling can be connected as in diagram 2.
ORT-01
OpenTherm connections
B
A
O
Important - To avoid damage to Boiler and Thermostat, connect only to OpenTherm connections on boiler, do not connect to any other power source.
O
in ORT- 01
Wires can be crossed
OpenTherm connections in boiler
NLNLGB
Wiring
7
Mounting
NLNLGB
Mounting
8
Locking and Limiting
1. Before removing dial, turn until setting 10 aligns with reference mark on front case.
2. Remove dial, lock or limit as required (see note below).
3. Replace dial, ensuring setting 10 aligns with reference mark on case.
Important Note: If Holiday Function is required DO NOT adjust lower limit.
1. 2.
NLNLGB
Locking and Limiting
9
User Instructions
NLNLGB
Unlike normal room thermostats, the ORT-01
Setting Dial
User Instructions
Daily use is as easy as setting the thermostat dial to the required setting, the advanced electronics and software within the thermostat establish two-way communication with the Opentherm boiler to ensure optimal operation.
In addition to the room temperature control, the ORT-01 also incorporates a feature which, dependant on boiler type, allows the domestic hot water store in the boiler to be kept hot or to be turned o, for example when on holiday. To select hot water o, simply turn the thermostat knob to the holiday position .
10
Indicator
varies the heat output of the Opentherm condensing boiler to which it is connected. This adds signicantly to the boiler eciency by ensuring that the boiler keeps in economical condensing mode whenever possible.
Settings
Room Temperature Setting 10 – 30°C: Set dial to required room temperature, domestic hot water store in boiler is kept hot*.
Holiday Setting : Controls room temperature at 8°C, (frost setting), domestic hot water store in boiler is turned o.
*(This feature is dependant upon boiler type).
Indication
Start-Up: When boiler is rst turned on the LED will ash for 20 seconds.
Normal Operation: LED will be lit whenever the boiler is ring.
Holiday Mode: When thermostat is put into, or taken out of holiday
setting the LED will ash for 20 seconds.
Alarm Mode: Should a fault occur with the boiler the LED will ash continuously to warn of failure.
NLNLGB
User Instructions
11
Technische Specicaties
NLNLNL
Technische Specicaties
Bestelnummer 087N774300
Temperatuurbereik 8 - 30°C
Maximale omgevingstemperatuur 45°C
Regelprincipe P + I
OpenTherm Protocol 2.3
Warm tapwater Comfort-functie
Warm tapwater Eco-functie (vakantie stand)
ID 14 regeling lage belasting
Technische Specicaties
Thermostaat output OpenTherm Data
Fabrikagenorm EN60730-2-9
Dichtheidsklasse IP20
Voedingsspanning 24V dc van ketel
Aansluiting: 2 draads, polariteit ongevoelig
Emissiewaarde Niveau 2
Afmetingen in mm (bxhxd) 85x86x42
12
Technische Specicaties
ErP
5
ErP-klasse
De in dit document beschreven producten zijn geclassiceerd over­eenkomstig de richtlijn voor energiegerelateerde producten (ErP) en stellen u in staat om zowel het datablad voor het systeempakket als het ErP-systeemlabel aan te maken. De ErP-labelverplichting gaat in op 26 september 2015.
ErP-klasse Productfunctie en ErP-beschrijving
Modulerende kamerthermostaat, voor gebruik met modulerende verwarmingen
Een elektronische kamerthermostaat die de stromingstemperatuur van het water vanuit de verwarming varieert op basis
V
van de gemeten afwijking van de kamer­temperatuur ten opzichte van het setpoint van de kamerthermostaat. De regeling
Product
Class
vindt plaats door het uitgangsvermogen van de verwarming te moduleren.
Extra
rendement
NLNLNL
Technische Specicaties
3%
13
Positionering / Installatie
NLNLNL
ORT-01
(5FT)
Positionering / Installatie
14
Bedrading
1.
For surface mounted wiring, cutouts are provided on the backplate to enable correct positioning of the cable.
NLNLNL
Bedrading
2.
For recessed wiring, cabling can be connected as in diagram 2.
15
Bedrading
NLNLNL
OpenTherm
OpenTherm
connections
aansluiting in
B
A
in ORT- 01
ORT-01
Bedrading
Wires can be
Draden mogen
crossed
gewisseld worden
OpenTherm
OpenTherm connections
aansluiting in
O
O
Belangrijk - Om schade aan ketel en thermostaat te voorkomen dient de thermostaat alleen op de OpenTherm aansluiting van de ketel te worden aangesloten.
16
in boiler
ketel
Montage
NLNLNL
Montage
17
Blokkeren & Begrenzen
NLNLNL
1. Draai de instelknop op stand 10.
2. Verwijder de instelknop en blokkeer of begrens naar behoefte ( zie onderstaand schema).
3. Plaats de instelknop op stand 10 weer terug.
Let op: Stel geen minimum begrenzing in als de Vakantie Stand
nodig is.
Blokkeren & Begrenzen
1. 2.
18
Gebruikers handleiding
Anders dan bij normale aan/uit thermostaten regelt de ORT­01 de warmteafgifte van de
Instelknop
OpenTherm ketel waarop hij is aangesloten. Dit draagt in hoge mate bij aan het ketelrendement door te zorgen dat de ketel zo lang
LED
mogelijk in HR (condenserend)
Indicator
zeer eenvoudig door de instelknop van de thermostaat simpelweg op de gewenste temperatuur in te stellen. De geavanceerde elektronika en innovatieve software in de thermostaat verzorgen de twee-weg-communicatie met de OpenTherm ketel en verzekeren een optimale werking. Naast de nauwkeurige ruimtetemperatuurregeling voorziet de ORT-01 ook in de funktie, afhankelijk van het type ketel, om de warme tapwatervoorraad op temperatuur te houden (comfort) of uit te schakelen (eco), bijvoorbeeld tijdens vakanties buitenshuis. Om de eco-funktie te aktiveren dient de instelknop op de vakantiestand te worden gezet.
bedrijf werkt. Dagelijks gebruik is
NLNLNL
Gebruikers handleiding
19
Instellingen
NLNLNL
Ruimtetemperatuur instelling 10 – 30°C: Zet de instelknop op de gewenste ruimtetemperatuur, tapwater voorraad wordt op temperatuur gehouden*.
Vakantiestand : Regelt de ruimtetemperatuur op 8°C,
Instellingen
(vorst beveiliging), warm tapwater uitgeschakeld*.
*(Deze funktie is afhankelijk van het keteltype).
LED-indicator
Opstarten: Na het inschakelen van de voedingsspanning van de ketel knippert de LED gedurende 20 seconden.
Normaal bedrijf: LED is aan wanneer de ketel brandt.
Vakantiestand: Wanneer de thermostaat op Vakantiestand wordt
gezet knippert de LED twee keer, bij terugzetten op normaal bedrijf een keer.
Alarm funktie: Indien zich een fout in de ketel voordoet, zal de LED als waarschuwing continu knipperen.
20
212223
www.heating.danfoss.co.uk
24
Part No 25219 Issue 4 06/2015 (VIRLA14L)