Danfoss Orifice replacement procedure Installation guide

Danfoss Orifice replacement procedure Installation guide

Service Kit Instructions

Series 45 Servo and Gain Control Orifices

Orifice replacement procedure

Series 45 Electric Proportional Control kits for frames E, F, J, and K2 come from the factory with a 1.2mm gain orifice and 0.8mm servo control orifice installed in the control assembly. A 1.0mm servo control orifice is included in this kit in the event it is required. Also, included in this kit is a 1.0mm and 0.8mm gain control orifice in the event it is required.

If the control orifices require replacement, please refer to the instructions below.

Servo control orifice 1. Remove servo control orifice. replacement

2.Install required servo control orifce, and torque to 2-3.4 N•m [18-30 lbf•in].

Gain control orifice 1. Remove solenoid coil nut. replacement

2.Slide solenoid coil off.

3.Remove control solenoid actuator.

2.Remove plug.

3.Remove gain control orifice.

4.Install required gain control orifice, and torque to 2-3.4 N•m [18-30 lbf•in].

 

Solenoid actuator

 

 

 

 

 

17 mm

 

 

 

Solenoid nut

Screws

 

 

 

 

23.0-28.5 N•m

 

 

 

Feature

4 mm

 

 

 

 

[17-21 lbf•in]

 

 

 

2.5-4.5 N•m

 

 

 

 

6.5 N•m

 

 

 

Solenoid coil

[1.8-3.3 lbf•in

[4.75 lbf•in]

 

 

 

 

 

 

Plug

3 mm

 

 

 

 

 

2-3.4 N•m

 

 

 

 

 

[18-30 lbf•in]

 

 

 

Gain orifice

3 mm

 

 

 

 

 

2-3.4 N•m

 

 

 

 

[18-30 lbf•in]

 

 

Servo control

 

 

 

 

orifice

3 mm

 

 

 

 

 

2-3.4 N•m

 

 

 

 

 

[18-30 lbf•in]

 

 

 

 

© Danfoss, 2015

11170669 • Rev BA • May 2017

 

1