Danfoss Optyma Trio HU3500D50, Optyma Trio HU4500D50, Optyma Trio HU2900D50, Optyma Trio HU5100D50, Optyma Trio LZ0012D50 Application Manual

...
Application Guide
Optyma™ Trio
http://RA.danfoss.com.br
Application Guide
Content
Contents
Introduction.......................................................................................................................... 4
2.4 Benets ............................................................................................................................................................................ 5
General Information ............................................................................................................ 5
Specications ....................................................................................................................... 6
3.2 Nomenclature ............................................................................................................................................................... 7
3.2 General Data ................................................................................................................................................................10
3.5 Electrical Data .............................................................................................................................................................10
3.6 Dimensional Data ..................................................................................................................................................... 11
4.1 Storage and Handling ...............................................................................................................................................12
4.2 Precautions ..................................................................................................................................................................12
Installation and Operation ................................................................................................ 12
4.3 Mechanical Installation ............................................................................................................................................13
4.4 Leak detection ............................................................................................................................................................ 14
4.5 Vacuum dehydration ................................................................................................................................................14
4.6 Electrical Installation ................................................................................................................................................14
4.7 Refrigerant and oil charge ......................................................................................................................................15
4.8 Verication before operating ................................................................................................................................15
4.9 First start-up .................................................................................................................................................................15
4.10 Verication of the unit while operating ..........................................................................................................15
Maintenance ....................................................................................................................... 16
Spare parts .......................................................................................................................... 17
Warranty ............................................................................................................................. 18
Danfoss Guideline .............................................................................................................. 19
3FRCC.PC.053.A1.02
Application Guide
Introduction
The content of this material applies only to “Optyma
TM
TRIO” condensing units. This product is a Danfoss technology solution with the use of three in parallel connected scroll compressors in a robust foil framework with high eciency micro-channel (MCHE) Danfoss condenser.
Even though a lot of benets for the use of in parallel compressor systems exist, the more important benets are the use of less equipment, exibility on the capacity control, use of few tubing lines, better control of energy consumption and reduction of installation time when compared to the use of dierent equipment with single compressor systems toobtain the same capacity.
4 FRCC.PC.053.A1.02
Application Guide
General Information
2.1 Application envelope of the Condensing Units for R404A / R507
Figure 1 Figure 2
50
45
40
35
30
25
20
T amb (°C)
15
10
5
0
-35 -30 -25 -20 -15 -10 -5 0510 15
2.2 Applications
T evap (°C)
This unit is intended for diverse applications, suchas:
• Medium capability refrigeration systems, ingeneral;
• Medium and small sized supermarkets;
MBP
2.3 Features
• Scroll Compressors;
• High eciency micro-channel condenser;
• Designed to operate in locations with high ambient temperature;
• Motorized fans of high performance and low energy consumption to obtain the maximum thermal eciency;
• Motorized fans developed specially to guarantee the perfect operation in humid environments and great diversity of dirt;
• 6 pole motorized fans selected to assist in low noise level operations with dynamic balancing;
• Designed for use in outdoor environments;
• Designed for easy installation and maintenance;
• Framework assembled in galvanized steel with electrostatic painting resistant to corrosion;
50
45
40
35
30
25
20
T amb (°C)
15
10
5
0
-45 -40 -35 -30 -25 -20 -15 -10 -5
T evap (°C)
• Distribution centers for freezing and food preservation;
• Industrial systems;
• Cold water and liquid cooling units, etc.
• Removable fan guards to facilitate the cleaning of the serpentine and general maintenance;
• Service valves in the liquid line and suction;
• Liquid receiver with service valves in the inlet and outlet connections, according to the NR10norm;
• Combined oil separator and oil reservoir;
• Individual oil control for each compressor through the electronic level regulators;
• Compressor with thermal shield for motor protection against high temperatures and currents;
• Applications for R404A;
• Electric panel according to the NR13 norm;
• There is enough space for the installation of additional controls, if necessary.
LBP
2.4 Benets
• Compact, light and resistant unit;
• Easy handling;
• Low noise level, 6-pole fan;
• High performance;
• Low energy consumption.
5FRCC.PC.053.A1.02
Application Guide
3.1 Illustrative Image
Figure 3
Specications
6 FRCC.PC.053.A1.02
Components
1 - Fan 2 - Micro-channel type condenser 3 - Electronic oil level control valve 4 - Scroll Compressors 5 - Combined separator and oil reservoir 6 - Oil lter 7 - Liquid receiver 8 - Base 9 - Service valve ( GBC) liquid line 10 - Service valve (GBC) suction line
11 - Sight glass 12 - Suction lters and liquid line 13 - High and low security pressure switch 14 - Fan’s control pressure switch 15 - Suction accumulator 16 - Complete electric panel (including
sectionalizers, compressor contactor, overload relay, fan contactor, circuit breaker, timers, fault relay/ phase sequence).
Loading...