NTY5.5FK
High Energy-optimized Compressor
R134a
115V 60Hz
General
Code number 105G5620
Approvals UL984
Compressors on pallet 80
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °F – -31 to 14
Voltage range V – 103 - 127
Max. condensing temperature continuous (short) °F – 140 (158)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – S – –
100°F – – – S – –
110°F – – – S – –
Remarks on application: Below 10°F only for 115V 60Hz nominal.
Motor
Motor type RSCR
LRA (rated after 4 sec. UL984), HST | LST A – 10.5
Cut in Current, HST | LST A – 20.4
Resistance, main | start winding (77°F) Ω 3.1 4.0
Design
Displacement cu.in 0.37
Oil quantity (type) .oz. 9.9 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 23.8
Dimensions
Height inch A 8.00
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Cu-plated steel | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Cu-plated steel | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Cu-plated steel | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.76
B1 –
B2 –
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.S5.22 / 520N1352 1/2

ASHRAE LBP Static cooling, with RC 15μF, 115V 60Hz, PTC consumption incl.
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 389 516 637 697 938 1247 1391
Power cons. in W 100 118 132 139 164 193 207
Current cons. in A 0.90 1.06 1.19 1.25 1.47 1.74 1.86
EER in BTU/Wh 3.91 4.39 4.82 5.02 5.72 6.45 6.74
EN 12900 Household (CECOMAF) Static cooling, with RC 15μF, 115V 60Hz, PTC consumption incl.
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 93 122 151 165 222 295 333
Power cons. in W 100 118 132 139 164 193 207
Current cons. in A 0.90 1.06 1.19 1.25 1.47 1.74 1.86
COP in W/W 0.93 1.04 1.14 1.18 1.35 1.52 1.61
Accessories for NTY5.5FK Figure Code number Test conditions
PTC starting device (Texas Instruments)
with reduced loss of energy TI 8EA 4B3 Ambient temp. 90°F 90°F
PTC starting device (Siemens)
with reduced loss of energy J506-A120-A320 Liquid temperature 90°F 131°F
a1
a1
(alt.)
117U6102 Condensing temp. 130°F 131°F
117U6106 Suction gas temp. 90°F 90°F
ASHRAE
LBP
EN 12900/
CECOMAF
Cover b 117U1026
Run capacitor 15 μF (compulsory) e 117-7118 Mounting accessories Code number
Protector (Texas Instruments) f
117U3306 Bolt joint for one comp. Ø: 5/8 in. 118-1917
TI-4TM419KFBYY-53 Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.S5.22 / 520N1352 June 2012