Danfoss NTY10FK Data sheet

Danfoss NTY10FK Data sheet

NTY10FK

High Energy-optimized Compressor R134a

115V 60Hz

Compressors

Data Sheet (Replaces CH.43.C1.22)

General

Compressor

 

NTY10FK

 

 

 

Connector-material

Sealing

Code number

 

 

 

Copper-plated steel

Aluminium caps

 

Copper-plated steel

Rubber plugs

105G5922

 

 

 

Copper

Rubber plugs

 

 

 

 

Application

Application

 

 

 

 

LBP

 

 

 

 

 

Evaporating temperature range

 

°F (°C)

 

-31 to 14 (-35 to -10)

 

 

 

 

 

 

Voltage range

 

 

V/Hz

 

103 - 127 /60

 

 

 

 

 

 

Motor type

 

 

 

 

RSCR*

 

 

 

 

 

Max. ambient temperature

 

°F (°C)

 

110 (43)

 

 

 

 

 

 

Comp. cooling at

 

 

 

 

 

max. ambient temperature

110°F (43°C)

 

F1

 

 

 

 

 

 

 

 

 

 

 

*run capacitor compulsory

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

 

cu.in. (cm3)

 

0.62 (10.09)

Oil quantity

 

 

fl.oz. (cm3)

 

9.9 (290)

Maximum refrigerant charge

 

oz. (g)

 

14.0 (400)

 

 

 

 

Free gas vol.in compressor housing

fl.oz. (cm3)

 

79.7 (2360)

Weight without electrical equipment lbs. (kg)

 

23.8 (10.8)

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor size

 

 

watt

 

285

 

 

 

 

LRA (rated after 4 sec.UL984) LST

A

 

20.3

 

 

 

 

 

 

Cut-in current LST

 

 

A

 

30.7

 

 

 

Resistance, main and start winding (77°F) Ω

 

1.8/3.1

 

 

 

 

 

 

Approvals

 

 

 

 

UL984/CSA-C22.2

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

 

in. (mm)

A

8.00 (203)

 

 

 

 

B

7.76 (197)

 

 

 

 

Suction connector

location/I.D. in. (mm)

C

0.320-0.327 (8.2±0.09)

 

 

 

 

Process connector

location/I.D. in. (mm)

D

0.252-0.259 (6.5±0.09)

 

 

 

 

Discharge connector

location/I.D. in. (mm)

E

0.252-0.259 (6.5±0.09)

 

 

 

 

 

 

Compressors on a pallet

 

 

pcs.

 

80

 

 

 

 

 

 

 

 

Application NTY10FK

105G

 

 

 

Blue stripe

 

R134a

 

 

 

 

SUCTION

 

 

 

 

 

 

 

 

 

 

CONNECTOR

5922

 

 

 

Barcode on

 

 

 

<![if ! IE]>

<![endif]>-9

 

 

white background

 

 

 

DANFOSS COMPRESSORS

<![if ! IE]>

<![endif]>8330

 

 

Green background

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

NTY10FK

 

 

 

 

 

 

 

115V-60Hz

 

 

 

 

 

 

 

1PH

 

 

 

 

 

 

 

THERMALLY

<![if ! IE]>

<![endif]>-10

 

 

 

 

 

 

<![if ! IE]>

<![endif]>8330

 

 

 

 

 

 

PROTECTED

S

= Static cooling normally sufficient

 

Approval mark

 

O

= Oil cooling

 

 

 

 

 

 

 

 

 

F1

= Fan cooling 1.5 m/s

 

 

 

 

(compressor compartment temperature

 

 

 

equal to ambient temperature)

 

 

F2

= Fan cooling 3.0 m/s necessary

 

 

6.54"(166)

2.83"(72)

2.34"(59.5)

51°

27°

<![if ! IE]>

<![endif]>2.13"

<![if ! IE]>

<![endif]>(54)

3.35"(85)

 

 

 

47°

 

 

 

 

 

 

 

 

 

 

 

 

 

4.45"(113)

4.69"(119)

 

 

 

 

 

 

 

5.00"(127)

 

 

 

D

 

 

8.10"(205)

 

 

E

 

 

 

 

 

 

 

C

 

°

35

A B

25

 

°

 

 

3.68"(93.5)

4.04"(102.5)

15

2.97"(75.5)

 

 

°

 

9.92"(252)

 

 

8252

 

 

8.03"(204)

 

 

6.70"(170)

 

5.20"(132)

4.00"(101.6)

2.76"(70)

1.38"(35)

 

 

 

6.50"(165)

 

 

 

7.32"(186)

ø0.75"(19)

ø0.63"(16)

ø0.38"(9.7)

July 2003

CH.43.C2.22

1

Capacity (ASHRAE)

 

 

 

 

Btu/h

Comp.\°F

-30

-20

-13

-10

0

10

14

Comp.\°C

-34.4

-28.9

-25

-23.3

-17.8

-12.2

-10

NTY10FK

635

873

1082

1183

1581

2085

2321

Capacity (EN 12900/CECOMAF)

 

 

 

watt

Comp.\°C

-34.4

-28.9

-25

 

-23.3

-17.8

-12.2

-10

Comp.\°F

-30

-20

-13

 

-10

0

10

14

NTY10FK

152

209

259

 

283

378

499

555

Power consumption

 

 

 

 

watt

Comp.\°F

-30

-20

-13

-10

0

10

14

Comp.\°C

-34.4

-28.9

-25

-23.3

-17.8

-12.2

-10

NTY10FK

164

200

226

238

281

331

354

Current consumption

 

 

 

 

A

Comp.\°F

-30

-20

-13

-10

0

10

14

Comp.\°C

-34.4

-28.9

-25

-23.3

-17.8

-12.2

-10

NTY10FK

1.89

2.12

2.31

2.41

2.78

3.21

3.41

EER (ASHRAE)

 

 

 

 

 

Btu/Wh

Comp.\°F

-30

-20

-13

-10

0

10

 

14

Comp.\°C

-34.4

-28.9

-25

-23.3

-17.8

-12.2

 

-10

NTY10FK

3.87

4.36

4.78

4.97

5.63

6.30

 

6.56

COP (EN 12900/CECOMAF)

 

 

 

 

 

 

 

W/W

Comp.\°C

 

-34.4

 

-28.9

 

 

-25

 

 

-23.3

-17.8

 

-12.2

-10

Comp.\°F

 

-30

 

-20

 

 

-13

 

 

-10

 

0

 

10

14

NTY10FK

 

0.93

 

1.05

 

1.14

 

1.19

 

1.35

 

1.51

1.57

Test conditions

 

 

 

 

 

ASHRAE

 

EN 12900/CECOMAF

Condensing temperature

 

 

 

130°F (54,4°C)

 

55°C (131°F)

 

Ambient and suction gas temp.

 

90°F (32°C)

 

32°C (90°F)

 

Liquid temperature

 

 

 

90°F (32°C)

 

55°C (131°F)

 

Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.

 

Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Devices

 

 

 

 

 

 

 

 

Fig.

 

 

 

NTY10FK

 

 

 

 

 

 

 

 

 

PTC starting device (Texas Instr.)

 

 

a1

 

 

 

117U6102

with reduced loss of energy

 

 

 

 

 

 

TI 8EA 4B3

 

 

 

 

 

 

 

 

PTC starting device (Siemens)

 

 

 

a1

 

 

 

117U6106

with reduced loss of energy

 

 

 

(alternative)

 

J506-A120-A320

Cover

 

 

 

 

 

 

 

 

b

 

 

 

117U1026

 

 

 

 

 

 

 

Run capacitor 15 F (compulsory)

 

 

e

 

 

117-7118

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protector (Texas Instruments)

 

 

 

 

f

 

 

 

117U3311

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TI-4TM805KDBZZ-53

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting accessories

 

 

 

 

 

Ø in. (mm)

 

 

 

 

 

Bolt joint for one compressor

 

 

 

5/8 (16)

 

 

118-1946

Bolt joint for one compressor

 

 

 

3/4 (19)

 

 

118-1949

Snap-on for one compressor

 

 

 

5/8 (16)

 

 

118-1947

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b

8233

e

 

 

a1

 

f

1

e

 

2

a1

4

 

3

 

Start winding

Main winding

Motor protector

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2

CH.43.C2.22

July 2003