BASIC OPERATION
Increasing/Decreasing the Temperature
By default, the thermostat displays the CURRENT temperature.
Press the Up/Down buttons ONCE to activate the backlight. Press
the Up/Down buttons again to adjust the TARGET temperature between 41 to 104° F (0 to 40°C). The screen will display the TARGET
temperature for five seconds.
Setting the Time
1. Press the Center button TWICE to access the Menu.
2. Using the Up/Down buttons, go to 12/24 and press the Center
button.
3. Select the time format (12-hour clock or 24-hour clock) and press
the Center button.
4. Using the Up/Down buttons, go to TIME and press the Center
button.
5. Set the hour and press the Center button.
6. Set the minutes and press the Center button.
7. Using the Up/Down buttons, go to EXIT and press the Center
button.
Changing the Temperature Unit
1. Press the Center button TWICE to access the Menu.
2. Using the Up/Down buttons, go to C/F and press the Center
button.
3. Select the temperature unit (Celsius or Fahrenheit) and press the
Center button.
4. Using the Up/Down buttons, go to EXIT and press the Center
button.
Changing the Temperature Control Setting
1. Press the Center button TWICE to access the Menu.
2. Using the Up/Down buttons, go to FLOOR/ROOM and press the
Center button.
3. Select the temperature control setting and press the Center button.
4. Using the Up/Down buttons, go to EXIT and press the Center
button.
Temperature
Control Setting
Floor (Default) The floor sensor controls the heating.
Room The built-in sensor controls the heating.
Floor/Room The built-in sensor controls the heating and
Changing the Floor Type (not selectable if the Temperature Control
setting is set to ROOM – refer to ‘Changing Temperature Control Setting’ section). Laminate is the default floor type.
1. Press the Center button TWICE to access the Menu.
2. Using the Up/Down buttons, go to TILE/LAMINATE and press the
Center button.
A. TILE - the floor temperature will be limited to 104°F/40°C
B. LAMINATE - the floor temperature will be limited to 82°F/28°C.
3. Select the floor type and press the Center button.
4. Using the Up/Down buttons, go to EXIT and press the Center button.
Monitoring Usage
1. Press the Center button TWICE to access the Menu.
2. Using the Up/Down buttons, go to HISTORY and press the Center
button.
A. The display will show the number of HOURS (denoted by the ’h’
on the right side of the screen) the floor heating system has been
heating over the past 7 days. When done, press the Center button.
3. Using the Up/Down buttons, go to EXIT and press the Center button.
Description
Floor protection is active. Limits as in Floor/Room.
This setting is useful if the temperature sensor in
the floor is damaged or none is installed.
Floor protection is NOT active.
the floor sensor limits the floor temperature to
104°F/40°C for Tile or 82°F/28°C for Laminate.
Troubleshooting
E02 - This error message indicates a missing or damaged floor sensor.
Contact your installer to verify the floor sensor and connections.
Classification
The product is a Class II device (reinforced insulation) and must be connected to the following leads:
Phase L1 (L) 120 V
Neutral L2 (N) 0/120 V
Max. load 15 A (resistive load) The thermostat is intended to be used with
underfloor heating.
The terminals are suitable for field wiring cables of 12 to 20 AWG.
Technical data
Supply . ...............................................................................120/240 Vac
Load ............................................................max. 15 A (resistive load)
Power .................................................................... 1.800 W at 120 Vac
.................................................................... 3.120 W at 208 Vac
.................................................................... 3.600 W at 240 Vac
GFCI (UTN4) .................................................Class A (5 mA trip level))
Floor sensor .............................................................NTC 10K Ω @ 25°C
UL Listed for the US and Canada
According to the following standards:
Thermostat: UL 60730-1
UL 60730-2-9
CSA E60730-1
CSA E60730-2-9
UL file number: E157297
UTN4 / GFCI: UL 943 fourth ed.
CSA C22.2 No. 144.1-06
Patent pending
Danfoss
Non-Programmable
Thermostat
QUICK GUIDE
GUIDE RAPIDE
Spare this document.
Piezas de este documento.
http://danfoss.ipapercms.dk/Heating/
AutoGen/43300_51044/?Purge=true
67547A 02/16 (ALA)
OPÉRATION DE BASE
Augmenter/Réduire la température
Par défaut, le thermostat ache la température ACTUELLE. Appuyer sur les boutons Up/Down UNE FOIS pour allumer le panneau
lumineux. Appuyez à nouveau sur les boutons Up/Down pour régler
la température CIBLE entre 41 et 104 °F (0 et 40 °C). L’écran affichera la température CIBLE pendant 5 secondes.
Régler l’heure
1. Appuyer sur le bouton centre DEUX FOIS pour accéder au menu.
2. À l’aide des boutons Up/Down, aller à 12/24 et appuyer sur le
bouton centre.
3. Sélectionner l’achage de l’heure (format horaire 12 ou 24 heures), puis appuyer sur le bouton centre.
4. À l’aide des boutons Up/Down, aller à HEURE et appuyer sur le
bouton centre.
5. Sélectionner l’heure et appuyer sur le bouton centre.
6. Sélectionner les minutes et appuyer sur le bouton centre.
7. À l’aide des boutons Up/Down, aller à QUITTER et appuyer sur le
bouton centre.
Changer l’unité de température
1. Appuyer sur le bouton centre DEUX FOIS pour accéder au menu.
2. À l’aide des boutons Up/Down, aller à C/F et appuyer sur le
bouton centre.
3. Sélectionner l’unité de température (Celcius ou Fahrenheit) et appuyer sur le bouton centre.
4. À l’aide des boutons Up/Down, aller à QUITTER et appuyer sur le
bouton centre.
Changer les réglages de température
1. Appuyer sur le bouton centre DEUX FOIS pour accéder au menu.
2. À l’aide des boutons Up/Down, aller à C/F et appuyer sur le
bouton centre.
3. Sélectionner l’unité de température (Celcius ou Fahrenheit) et appuyer sur le bouton centre.
4. À l’aide des boutons Up/Down, aller à QUITTER et appuyer sur le
bouton centre.
Réglage de la
température
Floor
(par défaut)
Room La sonde intégrée contrôle le chauage.
Floor/Room La sonde intégrée contrôle le chauage et la sonde
Changer le type de plancher (seulement possible si ROOM est
sélectionné – se reporter à la section Changer les réglages de
température) Le stratifié est le type de plancher par défaut.
1. Appuyer sur le bouton centre DEUX FOIS pour accéder au menu.
2. À l’aide des boutons Up/Down, aller à CARRELAGE/LAMINÉ et appuyer sur le bouton centre.
A. CARRELAGE – la température du plancher sera limitée à 104
°F/40 °C
B. LAMINÉ – la température du plancher sera limitée à 82 °F/28 °C
3. Sélectionner le type de plancher et appuyer sur le bouton centre.
4. À l’aide des boutons Up/Down, aller à QUITTER et appuyer sur le
bouton centre.
Contrôler l’utilisation
1. Appuyer sur le bouton centre DEUX FOIS pour accéder au menu.
2. À l’aide des boutons Up/Down, aller à HISTORIQUE et appuyer sur
le bouton centre.
A. L’écran achera le nombre d’HEURES (noté par le “h” à la droite
de l’écran) de fonctionnement du chauage pendant les 7 derniers
jours. Quand c’est terminé, appuyez sur le bouton du centre.
3. À l’aide des boutons Up/Down, aller à QUITTER et appuyer sur le
bouton centre.
Description
La sonde de plancher contrôle le chauage.
La protection du plancher est activée. Les limites
sont comme pour plancher/pièce.
Ce réglage est utile si la sonde de température
du plancher est endommagée ou s’il n’y en a pas
d’installée. La protection du plancher N’EST PAS
activée.
de plancher limite la température du plancher à
104 °F/40 °C pour des tuiles ou 82 °F/28 °C pour du
stratifié.
© 2016 OJ Electronics A/S
Dépannage
E02 - Ce message d’erreur indique un capteur de plancher manquant ou
endommagé. Communiquer avec l’installateur pour vérifier le capteur de
plancher et les connexions.
Classification
Ce produit est un appareil classé II (isolation renforcée) et doit être branché aux fils suivants :
Phase L1 (L) 120 V
Neutre L2 (N) 0/120 V
Charge maximum 15 A (charge résistive) Le thermostat est conçu pour
être utilisé avec des planchers chauants.
Les borniers sont adéquats pour du câble de construction de 12 à
20 AWG.
Caractéristiques techniques
Alimentation .......................................................................120/240 VCA
Charge ....................................................... Max. 15 A (charge résistive)
Puissance ................................................................ 1800 W à 120 VCA
..................................................................... 3120 W à 208 VCA
..................................................................... 3600 W à 240 VCA
DDFT (UTN4) ....................... Class A (5 mA, niveau de déclenchement)
Sonde de plancher ................................................. NTC 10K Ω @ 25 °C
c-UL-us
Selon les normes suivantes :
DISJONCTEUR DE FUITE À LA TERRE
Thermostat: UL 60730-1
UL 60730-2-9
CSA E60730-1
CSA E60730-2-9
Numéro de dossier UL E157297
UTN4 / DDFT: UL 943 quatrième éd.
CSA C22.2 No. 144.1-06
En instance de brevet.
WARNINGS:
To avoid electric shock, disconnect the heating system power supply
at the main panel before installation and maintenance of the thermostat. Keep thermostat air vents clean and free from obstruction. This
thermostat is an electrical device and must be installed in compli
ance with national and/or local electrical codes. Installation must be
performed by qualified personnel where required by law.
If a power module with an equipment ground fault protection device
(EGFPD) is to be installed where national and/or local electrical codes
require a ground fault circuit interrupter (GFCI), a separate GFCI must
also be installed.
AVERTISSEMENTS :
Pour éviter l’électrocution, coupez l’alimentation du système de chauffage au panneau principal avant de faire l’installation et/ou l’entretien
du thermostat. Maintenez les évents du thermostat propres et libres
d’obstruction. Ce thermostat est un appareil électrique et doit être
installé conformément aux codes électriques nationaux et/ou locaux.
L’installation doit être eectuée par du personnel qualifié quand la loi
l’exige.
Si un module de puissance possédant un circuit de protection contre
les fuites à la terre (EGFPD) doit être installé où les codes électriques
nationaux et/ou locaux requièrent un disjoncteur de fuite à la terre
(DDFT), un DDFT séparé doit aussi être installé.
For support please contact your installer or retailer.
Pour le soutien, communiquez avec votre installateur ou votre
détaillant.
Danfoss
11655 Crossroads Circle
Baltimore, MD 21220
1.866.676.8062
© 2016 OJ Electronics. All rights reserved.
This manual and parts thereof are protected under Danish and
international copyright laws.
© 2016 OJ Electronics. Tous droits réservés.
Ce manuel et son contenu sont protégés par les lois internationales et
danoises sur les droits d’auteur.
LX 205 Quick Guide/Guide rapide
BR1015A09b
© 2015 OJ Electronic A/S
BR1015A10b
© 2015 OJ Electronic A/S
BR1015A08b
© 2015 OJ Electronic A/S
BR1012C01a
© 2015 OJ Electronic A/S
OJ Microline
BR1012C03a
© 2015 OJ Electronic A/S
BR1012C02a
© 2015 OJ Electronic A/S
Contents/Contenu
1 2
Load no polarity
Charge sans polarité
Line (L)
1800W / 3600W MAX 15A
14
LOAD
2
120 / 240 VAC
LINE
L2(N)L1(L)
3
Ligne (L)
4
The floor sensor must not come in contact with
electrical wires within the wall and must be routed
outside the electrical box.
La sonde de plancher ne doit pas venir en contact avec les fils
électriques dans le mur et elle doit être acheminée à l’extérieur
du panneau électrique.
5
Thermostat
Thermostat
Push the power base into the electrical box.
Poussez le bornier de puissance dans le boîtier électrique.
Secure the power base to the wall.
Fixez le bornier de puissance au mur.
Floor sensor
Sonde plancher
The marked values
are default values
Les valeurs
inscrites sont les
valeurs par défaut.
Screws (2)
Vis (2)
6
BR1015A09b BR1012C01a
Loosen the screw at the bottom and remove the faceplate.
Do not attempt to remove the screw completely.
Desserrez la vis du bas et retirez la plaque frontale.
N’essayez pas d’enlever complètement la vis.
Make the sensor connections.
Faites le raccordement de la sonde.
The Floor sensor has no
polarity. Connect it to
terminals C and D.
La sonde de plancher n’a
pas de polarité. Raccordez-la aux bornes C et D.
C D
in / sensor
out
A B C D
Expansion unit
connects to termianals
A and B*
L’unité d’extension se
raccorde aux bornes A
et B*.
*Refer to instructions included with expansion unit.
*Consultez les instructions incluses avec l’unité d’extension.
A B
The trademark is registered and belongs to OJ Electronics A/S · © 2016 OJ Electronics A/S
3
7
BR1012C02aBR1012C03aBR1015A10a
Load no polarity
Charge sans polarité
Turn the power source OFF at the breaker panel.
Make the electrical connections to the power base. See Warnings.
AWG between 12 - 20
Note! Do not detach the screws from the terminals.
When fastening the screws use a torque between (0,6 - 0,8 ft.lbs).
Coupez l’alimentation par le disjoncteur du panneau électrique.
Faites les raccords électriques au bornier de puissance.
Voir avertissements.
AWG de 12 à 20
Noter! Ne pas les enlever des bornes.
Au serrage des vis, utilisez un couple de (0,6 - 0,8 ft.lbs).
Checking the GFCI
It is important that the GFCI is checked for correct installation and function
upon installation and monthly thereafter.
To check the GFCI:
Press the “TEST” button.
The test is successful if the red LED on the right of the thermostat flashes
once every two seconds and “GROUND FAULT” appears on the display. If
this does not occur, check the installation.
Press the “Standby/Reset” button to reset the GFCI/EGFPD.
The red LED will stop flashing and the display returns to its normal appearance.
If the test fails, repeat the test. If it continues to fail, ask an electrician to
check the installation.
If, during normal operation, the GFCI trips without the “TEST” button being
pressed, there could be a ground fault! To check whether it is a ground fault
or nuisance tripping, press “Standby/Reset”. If this causes the red LED to
stop flashing and stay off, it was nuisance tripping and the system is operating correctly. If this does not occur, there is a ground fault! In case of a
ground fault, it is important to have the installation checked by a qualified
electrician according to local and national regulations.
The red LED on the right of the thermostat can indicate four different
GFCI states:
1. LED off – NORMAL state.
2. LED flashing slowly (once every two seconds) – TRIGG state. Try pressing the “Standby/Reset” button to reset the GFCI.
3. LED flashing quickly (five flashes per second) – ERROR state. Try switching the power off and then back on again. If the thermostat re-enters the
ERROR state, either the wiring is wrong (a GN exists) or the unit is defective and must be replaced.
4. LED lit constantly – Internal microprocessor malfunction or abnormal fault
in hardware! Try switching the thermostat off and then back on again.
If the LED is still constantly lit, the GFCI is defective and the thermostat
must be replaced.
Note: The LED lights up briefly without flashing during every power-up.
Line (N
Ligne (N)
BR1015A01b
BR1015A08a
Floor sensor
Sensor de plancher
Thread the floor sensor cable through the hole in the power base.
Push the electrical wires to the back of the electrical box.
Passez le câble de la sonde de plancher dans le trou du bornier
de puissance.
Poussez les fils électriques au fond du boîtier électrique.
Vérification du DDFT
Il est important de vérifier l’installation et le fonctionnement adéquat du
DDFT à son installation et à chaque mois par la suite.
Pour vérifier le DDFT:
Appuyez sur le bouton TEST (essai). Le test sera concluant si la DEL
rouge du côté droit du thermostat clignote avec deux secondes d’intervalle et que «GROUND FAULT» s’affiche à l’écran. Si ce n’est pas le cas,
vérifiez l’installation.
Appuyez sur le bouton «attente/réarmement» pour réarmer le DDFT. La
DEL rouge arrêtera de clignoter et l’écran revient à son affichage normal.
Si l’essai ne fonctionne pas, répétez l’essai. Si l’essai ne fonctionne toujours pas, demander à un électricien de vérifier l’installation.
Si, pendant l’opération normale, le DDFT se déclenche sans que le bouton «ESSAI» ne soit utilisé, il peut y avoir une faute à la terre. Pour vérifier
si c’est une faute à la terre ou un déclenchement intempestif, appuyez
sur le bouton «attente/réarmement». Si la DEL rouge arrête de clignoter
et reste éteinte, c’était un déclenchement intempestif et le système fonctionne correctement. Si ce n’est pas le cas, il y a une faute à la terre. Dans
le cas d’une faute à la terre, il est important de faire vérifier l’installation
par un électricien qualifié selon la règlementation locale et nationale.
La DEL rouge du côté droit du thermostat peut signaler quatre différents
états du DDFT:
1. DEL éteinte – état NORMAL.
2. DEL clignotant lentement (une fois chaque deux secondes) – état de
DÉCLENCHEMENT. Essayez d’appuyer sur le bouton «attente/réarmement» pour réarmer le DDFT.
3. La DEL clignote rapidement (cinq clignotements par seconde) – état
d’ERREUR. Essayez de couper l’alimentation puis de la remettre. Si le
thermostat demeure toujours en état d’ERREUR, soit que le câblage
est incorrect (il y a MALT) ou l’appareil est défectueux et doit être remplacé.
4. La DEL est allumée de façon constante – mauvais fonctionnement
du microprocesseur interne ou une faute anormale dans le matériel.
Essayez de couper l’alimentation du thermostat puis de la remettre. Si
la DEL demeure allumée, le DDFT est défectueux et le thermostat doit
être remplacé.
Note : La DEL rouge s’allume brièvement sans clignoter à chaque mise
sous tension.