Danfoss NLY6F Data sheet

0 (0)
Danfoss NLY6F Data sheet

NLY6F

High Energy-optimized Compressor R134a

220-240V 50Hz

Compressors

Data Sheet (Replaces CD.43.H6.02)

General

Compressor

NLY6F

 

 

Code number

105G6630

 

 

Application

Application

 

 

 

LBP

 

 

 

 

Evaporating temperature range

°C

 

-35 to -10

 

 

 

 

 

Voltage range

 

V/Hz

 

198 - 254 /50

 

 

 

 

 

Motor type

 

 

 

RSCR*

 

 

 

 

 

Max. ambient temperature

 

°C

 

43

 

 

 

 

Comp. cooling at ambient temp.

32°C

 

S

 

 

38°C

 

S

 

 

43°C

 

S

 

 

 

 

 

 

 

 

 

* run capacitor 4 µF compulsory

Design

 

 

 

 

 

 

 

 

 

Displacement

 

cm3

 

6.70

 

 

 

 

 

Oil quantity

 

cm3

 

290

 

 

 

 

 

Maximum refrigerant charge

 

g

 

400

 

 

 

 

 

Free gas vol. in compressor

 

cm3

 

2310

 

 

 

 

Weight without electrical equipment

kg

 

10.8

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

Motor size

 

watt

 

135

 

 

 

 

LRA (rated after 4 sec. UL984) LST

A

 

4.3

 

 

 

 

 

Cut-in current LST

 

A

 

8.3

 

 

 

Resistance, main and start winding (25°C) Ω

 

16.0/15.1

 

 

 

 

 

Approvals

 

 

 

EN 60335-2-34 with Annex AA

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

Height

 

mm

A

203

 

 

 

B

197

 

 

 

 

Suction connector

location/I.D. mm

C

6.2 ±0.09

 

 

 

 

Process connector

location/I.D. mm

D

6.2 ±0.09

 

 

 

 

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

 

 

 

 

 

Compressors on a pallet

 

pcs.

 

80

 

 

 

 

 

Application

NLY6F

105G

 

Blue stripe

 

 

R134a

 

 

 

SUCTION

 

 

 

 

 

 

 

 

CONNECTOR

6630

 

Barcode on

 

 

 

 

 

Approvals

 

 

 

 

 

 

white background

 

DANFOSS COMPRESSORS

<![if ! IE]>

<![endif]>8280

Yellow background

 

 

 

S

= Static cooling normally sufficient

 

O

= Oil cooling

 

 

F1

= Fan cooling 1.5 m/s

 

 

 

(compressor compartment temperature

 

 

equal to ambient temperature)

 

F2

= Fan cooling 3.0 m/s necessary

 

 

204

 

 

170

 

<![if ! IE]>

<![endif]>100

<![if ! IE]>

<![endif]>70

 

 

ø16

 

178

 

D

205

E

 

 

 

 

C

 

°

35°

A B

25

 

 

15°

<![if ! IE]>

<![endif]>93.5

 

<![if ! IE]>

<![endif]>102.5

<![if ! IE]>

<![endif]>75.5

 

254

 

 

8250

 

<![if ! IE]>

<![endif]>166

<![if ! IE]>

<![endif]>72

<![if ! IE]>

<![endif]>60.5

51°

27°

<![if ! IE]>

<![endif]>54

<![if ! IE]>

<![endif]>78

 

 

 

47°

 

 

 

 

 

 

 

 

113119

127

August 2003

CD.43.H7.02

1

Loading...