NLV6.1F
Variable Speed Drive Compressor
R134a
115-127V 50-60Hz
General
Code number compressor (without electronic unit) 105G5660
Code number electronic unit 105N4212
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 45 -31 to 45
Voltage range V 80 - 140 80 - 140
Max. condensing temperature continuous (short) °F 140 (158) 140 (158)
Max. winding temperature continuous (short) °F 257 (275) 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F2F2– F2F2–
100°F F
110°F F
Remarks on application:
Features
Speed range rpm 2000 - 4000
Control modes with
integrated speed control AEO*
External speed control - 5V DC 200-400Hz
Protections - current
Motor
Motor type permanent magnet
LRA (rated after 4 sec. UL984), HST A electronic cut-off
Cut in Current, HST A 6
Resistance, all 3 windings (77°F) Ω 2.0
Design
Displacement cu.in 0.37
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight: Compressor / Electronic unit lbs. 23.8 / 1.3
Dimensions
Height inch A 7.99
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
Oil cooler connector location, I.D. in. | angle F –
Remarks:
)
material | comment Copper | Rubber plug
material | comment Copper | Rubber plug
material | comment Copper | Rubber plug
material | comment –
LBP MBP HBP LBP MBP HBP
2F2
2F2
- mech. thermostat 115V ON/OFF
- 5V DC ON/OFF
- speed
- temperature
*) AEO - Adaptive Energy Optimizer
B 7.76
B1 –
B2 –
– F2F2–
– F2F2–
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.300.B4.22 / 520N1000 1/2

Capacity (ASHRAE) Btu/h
rpm \ °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
2,000 190 292 378 419 577 771 859 1006 1288 1622 1658 1810
3,000 307 453 577 636 863 1142 1270 1481 1887 2367 2420 2638
3,500 388 560 706 776 1045 1376 1527 1777 2257 2826 2889 3147
4,000 409 603 767 846 1148 1519 1689 1970 2509 3148 3218 3508
Capacity (EN 12900 Household/CECOMAF) watt
rpm \ °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
2,000 45 69 89 99 137 182 204 238 305 383 392 428
3,000 73 107 137 151 205 271 301 351 447 560 572 623
3,500 92 133 167 184 248 326 362 421 534 668 683 744
4,000 97 143 182 200 272 360 400 467 594 744 761 829
Power consumption watt
rpm \ °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
2,000 56 68 77 81 94 108 114 122 135 148 149 154
3,000 87 106 119 125 145 165 173 185 206 227 229 238
3,500 108 132 150 157 182 207 218 233 260 288 291 303
4,000 123 151 170 179 207 236 248 266 296 326 329 341
Current consumption A
rpm \ °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
2,000 0.88 1.06 1.18 1.23 1.40 1.56 1.63 1.73 1.88 2.04 2.05 2.11
3,000 1.26 1.51 1.69 1.76 2.02 2.28 2.38 2.54 2.80 3.06 3.08 3.19
3,500 1.49 1.79 2.00 2.09 2.40 2.71 2.84 3.03 3.35 3.68 3.71 3.84
4,000 1.66 2.02 2.27 2.37 2.73 3.08 3.23 3.44 3.80 4.16 4.19 4.33
EER (ASHRAE)
Btu/Wh
rpm \ °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
2,000 3.38 4.28 4.90 5.17 6.10 7.12 7.55 8.24 9.51 10.96 11.11 11.76
3,000 3.54 4.28 4.83 5.08 5.96 6.94 7.35 8.01 9.17 10.43 10.57 11.10
3,500 3.60 4.23 4.71 4.94 5.74 6.64 7.02 7.61 8.67 9.80 9.91 10.38
4,000 3.32 4.00 4.51 4.74 5.54 6.43 6.81 7.41 8.48 9.65 9.77 10.27
COP (EN 12900 Household/CECOMAF) W/W
rpm \ °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
2,000 0.80 1.01 1.16 1.22 1.44 1.68 1.78 1.94 2.24 2.57 2.61 2.76
3,000 0.84 1.01 1.14 1.20 1.41 1.64
1.74 1.89 2.16 2.45 2.48 2.61
3,500 0.86 1.00 1.12 1.17 1.36 1.57 1.66 1.80 2.04 2.31 2.33 2.44
4,000 0.79 0.95 1.07 1.12 1.31 1.52 1.61 1.75 2.00 2.27 2.30 2.41
Legend
Number Description
1: Power supply
2: Fan connection
3: Thermostat connection
4: Light connection
5: Signal input
6: Mounting recesses
7: Cover
8: Cord relief
9: Electronic unit
10: Earth connection
11: Connector
12: Compressor
13: Screw 3.5 x 12 mm (3 pcs.)
14: Screw 3.5 x 25 mm (2 pcs.)
For further descriptions on connecting the electronic unit and the compressor, refer
to Instructions DES.I.300.B "Electronic Unit Type 105N4210 & 105N4212, 80-140V
50-60Hz for NLV Compressors".
Test conditions ASHRAE EN 12900/
CECOMAF
Condensing temperature 130°F 131°F
Ambient temperature 90°F 90°F
Suction gas temperature 90°F 90°F
Liquid temperature 90°F no subcooling
Accessories for NLV6.1F Code number
Bolt joint for one compressor Ø: 5/8 in. 118-1917
Bolt joint in quantities Ø : 5/ 8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.300.B4.22 / 520N1000 Dec 2011