Danfoss NLE8.0CN Data sheet

Datasheets
NLE8.0CN Energy-optimized LBP/MBP R290 115-127V 60Hz
General
Code number 105H6093 Code number (pre-assembled CSIR start equipment) 105H6095 Approvals UL984 Compressors on pallet 80 Compressors on pallet (with CSIR start equipment) 60
Application
Application LBP/MBP Frequency Hz 50 60 Evaporating temperature °F -31 to 45 Voltage range V 95 - 135 Max. condensing temperature continuous (short) °F 131 (149) Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60 Application 90°F F2F2– 100°F F 110°F F Remarks on application:
LBP MBP HBP LBP MBP HBP
2F2
2F2
S = Static cooling normally sufcient
O = Oil cooling
= Fan cooling 1.5 m/s
F
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Motor
Motor type CSIR/RSIR/RSCR LRA (rated after 4 sec. UL984), HST | LST A 25.5 21.7 Cut in Current, HST | LST A 25.5 29.4 Resistance, main | start winding (77°F) 2.1 6.3
Design
Displacement cu.in 0.49 Oil quantity (type) .oz. 10.8 (polyolester) Maximum refrigerant charge oz. 5.3 Free gas volume in compressor .oz. 79.8 Weight without electrical equipment lbs. 24.0
Dimensions
Height inch A 7.99
B 7.76 B1 – B2
Suction connector location, I.D. in. | angle C 0.320-0.327 | 45°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 15°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
DEHC.ED.100.E1.22
© Danfoss | DCS (CC) | 2015.10 | 1
ASHRAE LBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 860 1180 1430 1545 1970 2474 2702 3075 3789 3947 4636 4729 5115 Power cons. in W 217 253 278 288 323 357 370 389 420 426 449 452 463 Current cons. in A 3.09 3.30 3.45 3.52 3.76 4.01 4.11 4.26 4.51 4.55 4.73 4.76 4.84 EER in BTU/Wh 3.96 4.67 5.15 5.36 6.10 6.94 7.31 7.90 9.02 9.27 10.30 10.50 11.10
ASHRAE MBP/HBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 769 1055 1278 1380 1759 2208 2410 2741 3374 3514 4123 4205 4546 Power cons. in W 215 250 275 285 320 353 366 385 415 421 444 446 457 Current cons. in A 3.09 3.30 3.45 3.52 3.76 4.01 4.11 4.26 4.51 4.55 4.73 4.76 4.84 EER in BTU/Wh 3.58 4.22 4.65 4.84 5.50 6.26 6.59 7.12 8.13 8.35 9.30 9.42 9.95
EN 12900 LBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 279 362 429 461 578 720 784 888 1089 1133 1325 1351 1458 Power cons. in W 228 256 275 283 308 332 341 354 373 377 391 392 398 Current cons. in A 3.13 3.27 3.37 3.42 3.58 3.73 3.79 3.88 4.01 4.04 4.12 4.13 4.16 COP in W/W 1.22 1.42 1.56 1.63 1.88 2.17 2.30 2.51 2.92 3.01 3.39 3.44 3.66
EN 12900 MBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 260 342 407 438 551 687 748 848 1040 1082 1265 1290 1392 Power cons. in W 220 249 270 278 306 332 342 356 379 383 398 400 407 Current cons. in A 3.13 3.29 3.41 3.47 3.65 3.84 3.92 4.03 4.20 4.23 4.35 4.36 4.41 COP in W/W 1.18 1.37 1.51 1.57 1.80 2.07 2.19 2.38 2.75 2.83 3.17 3.22 3.42
Accessories for NLE8.0CN Figure Code number Test conditions
ePTC starting device 1/4 in. spade connectors a1 103N0058 *
)
Condensing temperature 104°F 113°F Starting relay 1/4 in. spade connectors a2 117U7013 Ambient temperature 90°F 90°F Start. capacitor 240 µF 1/4 in. spade connectors c 117U5023 Suction gas temperature 68°F 68°F Cover b 103N2011 Liquid temperature no subcooling
EN 12900
LBP MBP
ASHRAE
LBP MBP
130°F 130°F
90°F 90°F 90°F 95°F 90°F 115°F
Cord relief d 103N1010
)
Remarks: RSIR and RSCR option available in 4th quarter 2015 Mounting accessories Code number
*
Bolt joint for one comp. Ø: 3/4 in. 118-1949
Bolt joint for one comp. Ø: 5/8 in. 118-1946
Snap-on for one comp. Ø: 5/8 in. 118-1947
2 | © Danfoss | DCS (CC) | 2015.10
DEHC.ED.100.E1.22
ASHRAE LBP 115V, 60Hz, RC 20 µF, ePTC consumption incl., fan cooling F
Danf already on order pro All trademarks in this material are property of the respec
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 875 1206 1463 1581 2017 2530 2761 3137 3853 4010 4695 4787 5170 Power cons. in W 206 240 263 272 304 334 346 363 389 394 413 416 424 Current cons. in A 2.95 3.12 3.26 3.32 3.54 3.76 3.85 3.98 4.18 4.22 4.36 4.38 4.44 EER in BTU/Wh 4.24 5.03 5.57 5.81 6.64 7.57 7.98 8.64 9.89 10.20 11.40 11.50 12.20
ASHRAE MBP/HBP 115V, 60Hz, RC 20 µF, ePTC consumption incl., fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 860 1141 1363 1467 1850 2305 2509 2842 3476 3615 4219 4300 4636 Power cons. in W 219 248 268 277 304 330 340 354 375 379 394 396 403 Current cons. in A 2.98 3.12 3.23 3.28 3.45 3.62 3.69 3.78 3.93 3.95 4.04 4.05 4.09 EER in BTU/Wh 3.94 4.60 5.09 5.30 6.09 6.99 7.39 8.03 9.26 9.53 10.70 10.90 11.50
EN 12900 LBP 115V, 60Hz, RC 20 µF, ePTC consumption incl., fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 284 370 439 471 592 736 800 906 1107 1151 1342 1368 1474 Power cons. in W 217 243 260 267 290 311 319 330 346 349 360 361 365 Current cons. in A 2.98 3.10 3.19 3.23 3.37 3.50 3.55 3.62 3.72 3.74 3.79 3.80 3.81
COP in W/W 1.31 1.52 1.69 1.76 2.04 2.36 2.51 2.75 3.20 3.30 3.73 3.79 4.04
EN 12900 MBP 115V, 60Hz, RC 20 µF, ePTC consumption incl., fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 264 349 417 448 564 702 764 865 1057 1099 1281 1306 1407 Power cons. in W 209 236 255 263 288 311 320 332 351 354 367 368 374 Current cons. in A 2.98 3.12 3.23 3.27 3.44 3.60 3.67 3.76 3.89 3.92 4.00 4.01 4.04 COP in W/W 1.26 1.48 1.63 1.70 1.96 2.26 2.39 2.60 3.01 3.10 3.49 3.55 3.77
Accessories for NLE8.0CN Figure Code number Test conditions
ePTC starting device 1/4 in. spade connectors a1 103N0058 * Run capacitor 20 µF 1/4 in. spade connectors (optional) Suction gas temperature 68°F 68°F Cover b 103N2011 Liquid temperature no subcooling Cord relief d 103N1010
)
Remarks: RSIR and RSCR option available in 4th quarter 2015 Mounting accessories Code number
*
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
3 | © Danfoss | DCS (CC) | 2015.10
)
Condensing temperature 104°F 113°F
e n/a *
)
Ambient temperature 90°F 90°F
Bolt joint for one comp. Ø: 3/4 in. 118-1949
Bolt joint for one comp. Ø: 5/8 in. 118-1946
Snap-on for one comp. Ø: 5/8 in. 118-1947
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
EN 12900
LBP MBP
ASHRAE
LBP MBP
130°F 130°F
90°F 90°F 90°F 95°F 90°F 115°F
DEHC.ED.100.E1.22
Loading...