NLE7F
105G
6702
NLE7F
8279-2
DANFOSS COMPRESSORS
Barcode on
white background
Yellow background
Blue stripe
Application
Approvals
R134a
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.N2.02)
General
Compressor NLE7F
Code number 105G6702
Application
Application LBP
Evaporating temperature range °C -35 to -10
Voltage range V/Hz 198 - 254 /50
Motor type RSIR/RSCR
Max. ambient temperature °C 38
Comp. cooling at ambient temp. 32°C S
38°C S
Design
Displacement cm
Oil quantity cm
Maximum refrigerant charge g 400
Free gas vol. in compressor cm
Weight without electrical equipment kg 10.1
Motor
Motor size watt 140
LRA (rated after 4 sec. UL984) LST A 5.0
Cut-in current LST A 9.4
Resistance, main and start winding (25°C) Ω 14.9/17.9
Approvals EN 60335-2-34 with Annex AA
Dimensions
Height mm A 197
Suction connector location/I.D. mm C 6.2 ±0.09
Process connector location/I.D. mm D 6.2 ±0.09
Discharge connector location/I.D. mm E 5.0 +0.12/+0.20
Compressors on a pallet pcs. 80
3
3
3
B 191
7.27
290
2310
S = Static cooling normally sufficient
O = Oil cooling
F1= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2= Fan cooling 3.0 m/s necessary
70
100
D
25°
B
A
93.5
254
204
170
178
205
ø16
102.5
E
C
35°
15°
75.5
8248
166
60.5
November 2001 CG.43.N3.02 1
72
51°
113
27°
119
127
47°
54
78

Capacity (EN 12900/CECOMAF) watt
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material.Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
C°\.pmoC53-03-52-3.32-02-51-01-
F7ELN8679531051281832203
Capacity (ASHRAE) watt
C°\.pmoC53-03-52-3.32-02-51-01-
F7ELN48911661581422392373
Power consumption watt
C°\.pmoC53-03-52-3.32-02-51-01-
F7ELN48701131931651181702
Current consumption A
C°\.pmoC53-03-52-3.32-02-51-01-
F7ELN66.027.008.038.088.089.090.1
COP (EN 12900/CECOMAF) W/W
C°\.pmoC53-03-52-3.32-02-51-01-
F7ELN18.009.030.180.171.123.164.1
COP (ASHRAE) W/W
C°\.pmoC53-03-52-3.32-02-51-01-
F7ELN00.111.172.133.144.126.108.1
Test conditions EN 12900/CECOMAF ASHRAE
Condensing temperature 55°C55°C
Ambient and suction gas temp. 32°C32°C
Liquid temperature 55°C32°C
Static cooling, 220V 50Hz,
PTC consumption incl.
(pos.1)
g
b
Main winding
Winding protector
g
8217
a1
d
Start winding
a1
N
N
L
C
e
b
Accessories
seciveD.giFF7ELN
sedapsmm3.6ecivedgnitratsCTP
1a
)1.sop(
sedapsmm8.4
sedapsmm3.6ecivedgnitratsCTP
1a
)2.sop(
sedapsmm8.4
revoCb0102N301
1100N301
8100N301
6100N301
1200N301
Main winding
feilerdroCd0101N301
4roticapacnuR µ )lanoitpo(F
sedapsmm3.6
e7117-711
sedapsmm8.4
9117-711
CTProfneercsnoitcetorPg6740N301
seirosseccagnitnuoM
rosserpmocenoroftniojtloB
seititnauqnitniojtloB
seititnauqnino-panS
7191-811
8191-811
9191-811
(pos.2)
Winding protector
a1
d
e
N
a1
S
Start winding
N
L
C
8223
2 CG.43.N3.02 November 2001