Datasheets
NLE15MKK
Energy-optimized MBP Compressor
R600, 220-240V 50Hz
General
Code number 105H6533
Approvals EN 60335-2-34
Compressors on pallet 80
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -25 to 7.2 –
Voltage range V 198 - 254 –
Max. condensing temperature continuous (short) °C 60 (70) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C – S – – – –
38°C – S – – – –
43°C – S – – – –
Remarks on application:
Motor
Motor type RSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A – 8.4
Cut in Current, HST | LST A – 13.1
Resistance, main | start winding (25°C) Ω 9.0 12.0
LBP MBP HBP LBP MBP HBP
This product is approved for
R290 regarding explosion
safety according to standard
EN 60335-1 and EN 603352-34
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 10.8
Dimensions
Height mm A 203
Suction connector location/I.D. mm | angle C 6.2 | 15°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 5.0 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
3
3
3
B 197
B1 –
B2 –
320 (mineral)
14.65
2360
© Danfoss | DCS (CC) | 2017.04
DEHC.ED.200.D7.02 | 1
EN 12900 Household (CECOMAF) 220V, 50Hz, 2 W PTC consumption incl., static cooling
Danf
already on order pro
All trademarks in this material are property of the respec
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 172 189 225 288 365 423 456 563 687 748
Power cons. in W 154 162 178 203 227 245 254 282 313 327
Current cons. in A 1.24 1.26 1.31 1.39 1.48 1.54 1.58 1.69 1.81 1.87
COP in W/W 1.12 1.17 1.26 1.42 1.60 1.73 1.80 2.00 2.20 2.29
ASHRAE LBP 220V, 50Hz, 2 W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 210 230 274 352 446 517 557 688 840 915
Power cons. in W 154 162 178 202 227 244 253 281 312 326
Current cons. in A 1.24 1.26 1.31 1.39 1.48 1.54 1.58 1.69 1.81 1.87
COP in W/W 1.37 1.42 1.54 1.74 1.97 2.12 2.20 2.45 2.70 2.80
Accessories for NLE15MKK Figure Code number Test conditions
EN 12900/
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0021 Liquid temperature no subcooling 32°C
ePTC starting device 4.8 mm spade connectors 103N0050
a1
(pos.1)
a1
(pos.2)
103N0011 Condensing temperature 55°C 54.4°C
103N0016 Suction gas temperature 32°C 32°C
Cover b 103N2010
Run capacitor 4 µF 6.3 mm spade connectors
(optional) 4.8 mm spade connectors 117-7119 Bolt joint for one comp. Ø: 16 mm 118-1917
e
117-7117 Mounting accessories Code number
Cord relief d 103N1010 Bolt joint in quantities Ø: 16 mm 118-1918
Protection screen for PTC g 103N0476 Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.04 DEHC.ED.200.D7.02
ASHRAE LBP