Datasheets
NLE12.6MN Energy-optimized
MBP R290 220-240V 50Hz
General
Code number |
|
|
|
|
|
105H6377 |
|
|
|
||
Approvals |
|
|
EN 60335-2-34 w. Annex AA |
||||||||
Compressors on pallet |
|
|
|
|
|
80 |
|
|
|
||
Application |
|
|
|
|
|
|
|
|
|
|
|
Application |
|
|
|
|
|
MBP |
|
|
|
||
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
|
Evaporating temperature |
|
°C |
-25 to 10 |
|
|
– |
|
||||
Voltage range |
|
V |
198 to 254 |
|
|
– |
|
||||
Max. condensing temperature continuous (short) |
°C |
|
55 (65) |
|
|
– |
|
||||
Max. winding temperature continuous (short) |
°C |
125 (135) |
|
|
– |
|
|||||
Cooling requirements |
|
|
|
|
|
|
|
|
|
|
|
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
|
Application |
|
|
LBP |
|
MBP |
HBP |
|
LBP |
MBP |
|
HBP |
32°C |
|
|
– |
|
F2 |
– |
|
– |
– |
|
– |
38°C |
|
|
– |
|
F2 |
– |
|
– |
– |
|
– |
43°C |
|
|
– |
|
F2 |
– |
|
– |
– |
|
– |
Remarks on application: |
|
|
|
|
|
|
|
|
|
|
|
Motor |
|
|
|
|
|
|
|
|
|
|
|
Motor type |
|
|
|
|
CSIR/RSIR/RSCR |
|
|||||
LRA (rated after 4 sec. UL984), HST | LST |
A |
|
14.4 |
|
|
|
15.1 |
|
|
||
Cut in Current, HST | LST |
|
A |
|
14.4 |
|
|
|
16.9 |
|
|
|
Resistance, main | start winding (25°C) |
Ω |
|
4.9 |
|
|
|
7.9 |
|
|
||
Design |
|
|
|
|
|
|
|
|
|
|
|
Displacement |
|
cm3 |
|
|
|
12.55 |
|
|
|
||
Oil quantity (type) |
|
cm3 |
|
|
320 (polyolester) |
|
|||||
Maximum refrigerant charge |
|
g |
|
|
|
150 |
|
|
|
||
Free gas volume in compressor |
|
cm3 |
|
|
|
2360 |
|
|
|
||
Weight without electrical equipment |
kg |
|
|
|
12.1 |
|
|
|
|||
Dimensions |
|
|
|
|
|
|
|
|
|
|
|
Height |
|
mm |
A |
|
|
203 |
|
|
|
||
|
|
|
B |
|
|
197 |
|
|
|
||
|
|
|
B1 |
|
|
|
– |
|
|
|
|
|
|
|
B2 |
|
|
|
– |
|
|
|
|
Suction connector |
location/I.D. mm | angle |
C |
|
|
8.2 | 45° |
|
|
|
|||
|
material | comment |
|
|
Copper | Rubber plug |
|
||||||
Process connector |
location/I.D. mm | angle |
D |
|
|
6.2 | 25° |
|
|
|
|||
|
material | comment |
|
|
Copper | Rubber plug |
|
||||||
Discharge connector |
location/I.D. mm | angle |
E |
|
|
6.2 | 15° |
|
|
|
|||
|
material | comment |
|
|
Copper | Rubber plug |
|
||||||
Oil cooler connector |
location/I.D. mm | angle |
F |
|
|
|
– |
|
|
|
||
|
material | comment |
|
|
|
|
– |
|
|
|
||
Connector tolerance |
I.D. mm |
|
|
|
±0.09 |
|
|
|
|||
Remarks: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S |
= Static cooling normally sufficient |
||||||||||||||||||||||||||
O |
= Oil cooling |
||||||||||||||||||||||||||
F1 |
= Fan cooling 1.5 m/s |
||||||||||||||||||||||||||
|
|
(compressor compartment temperature |
|||||||||||||||||||||||||
|
|
equal to ambient temperature) |
|||||||||||||||||||||||||
F2 |
= Fan cooling 3.0 m/s necessary |
||||||||||||||||||||||||||
SG |
= Suction gas cooling normally sufficent |
–= not applicable in this area
© Danfoss | DCS (CC) | 2015.10 |
DEHC.ED.400.J9.02 | 1 |