Datasheets
NLE12.6MFT
Energy-optimized Tropical Compressor
R134a, 220-240V 50Hz
General
Code number 105G6388
Approvals EN 60335-2-34 w. Annex AA
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -35 to 10 –
Voltage range V 187 - 254 –
Max. condensing temperature continuous (short) °C 65 (70) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2– – – –
38°C F2F2– – – –
43°C F2F2– – – –
Remarks on application:
Motor
Motor type CSIR/RSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A 13.7 14.4
Cut in Current, HST | LST A 13.7 19.4
Resistance, main | start winding (25°C) Ω 4.9 8.9
LBP MBP HBP LBP MBP HBP
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 600
Free gas volume in compressor cm
Weight without electrical equipment kg 11.5
Dimensions
Height mm A 203
Suction connector location/I.D. mm | angle C 8.2 | 45°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 15°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
320 (polyolester)
B 197
B1 –
B2 –
12.55
2360
© Danfoss | DCS (CC) | 2017.04
DEHC.ED.200.F7.02 | 1
EN 12900 LBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 199 254 334 367 440 572 730 848 914 1123 1360 1472 1623
Power cons. in W 181 205 234 245 268 304 342 368 381 422 461 479 500
Current cons. in A 1.96 1.97 2.02 2.04 2.09 2.17 2.28 2.35 2.39 2.52 2.65 2.71 2.78
COP in W/W 1.10 1.24 1.42 1.50 1.65 1.88 2.14 2.31 2.40 2.67 2.95 3.08 3.24
2
EN 12900 MBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 193 236 305 335 400 521 668 779 841 1040 1265 1373 1518
Power cons. in W 184 207 236 246 269 305 345 372 387 429 472 491 515
Current cons. in A 1.97 1.98 2.02 2.04 2.09 2.18 2.29 2.37 2.42 2.56 2.70 2.77 2.85
COP in W/W 1.05 1.14 1.30 1.36 1.49 1.71 1.94 2.09 2.18 2.42 2.68 2.79 2.95
ASHRAE LBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 241 268 327 355 420 545 703 826 894 1119 1378 1502 1670
Power cons. in W 178 200 228 239 262 301 343 372 388 435 483 504 531
Current cons. in A 1.98 1.99 2.03 2.05 2.10 2.21 2.33 2.43 2.48 2.65 2.83 2.91 3.02
COP in W/W 1.36 1.34 1.43 1.48 1.60 1.81 2.05 2.22 2.31 2.58 2.85 2.98 3.15
ASHRAE MBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 215 239 292 317 374 486 626 735 796 995 1224 1334 1482
Power cons. in W 176 198 226 237 260 298 339 368 384 430 477 498 524
Current cons. in A 1.98 1.99 2.03 2.05 2.10 2.21 2.33 2.43 2.48 2.65 2.83 2.91 3.02
COP in W/W 1.22 1.21 1.29 1.34 1.44 1.63 1.85 2.00 2.08 2.32 2.57 2.68 2.83
2
2
2
Accessories for NLE12.6MFT Figure Code number Test conditions
ePTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0050 Ambient temperature 32°C 32°C 32.2°C 35°C
Starting relay 6.3 mm spade connectors a2 117U6005 Suction gas temperature 20°C 20°C 32.2°C 35°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature no subcooling 32.2°C 46.1°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
a1
– Condensing temperature 40°C 45°C 54.4°C 54.4°C
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
© Danfoss | DCS (CC) | 2017.04
EN 12900
LBP MBP
DEHC.ED.200.F7.02 | 2
ASHRAE
LBP MBP