Datasheets
NLE11MN Energy-optimized
LBP/MBP R290 220-240V 50Hz
General
Code number |
|
|
|
|
|
105H6177 |
|
|
|
||
Approvals |
|
|
EN 60335-2-34 w. Annex AA |
||||||||
Compressors on pallet |
|
|
|
|
|
80 |
|
|
|
||
Application |
|
|
|
|
|
|
|
|
|
|
|
Application |
|
|
|
|
|
MBP |
|
|
|
||
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
|
Evaporating temperature |
|
°C |
-30 to 10 |
|
|
– |
|
||||
Voltage range |
|
V |
198 to 254 |
|
|
– |
|
||||
Max. condensing temperature continuous (short) |
°C |
|
55 (65) |
|
|
– |
|
||||
Max. winding temperature continuous (short) |
°C |
125 (135) |
|
|
– |
|
|||||
Cooling requirements |
|
|
|
|
|
|
|
|
|
|
|
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
|
Application |
|
|
LBP |
|
MBP |
HBP |
|
LBP |
MBP |
|
HBP |
32°C |
|
|
– |
|
F2 |
– |
|
– |
– |
|
– |
38°C |
|
|
– |
|
F2 |
– |
|
– |
– |
|
– |
43°C |
|
|
– |
|
F2 |
– |
|
– |
– |
|
– |
Remarks on application: |
|
|
|
|
|
|
|
|
|
|
|
Motor |
|
|
|
|
|
|
|
|
|
|
|
Motor type |
|
|
|
|
CSIR/RSIR/RSCR |
|
|||||
LRA (rated after 4 sec. UL984), HST | LST |
A |
|
13.7 |
|
|
|
14.5 |
|
|
||
Cut in Current, HST | LST |
|
A |
|
13.7 |
|
|
|
19.4 |
|
|
|
Resistance, main | start winding (25°C) |
Ω |
|
4.9 |
|
|
|
8.9 |
|
|
||
Design |
|
|
|
|
|
|
|
|
|
|
|
Displacement |
|
cm3 |
|
|
|
11.15 |
|
|
|
||
Oil quantity (type) |
|
cm3 |
|
|
320 (polyolester) |
|
|||||
Maximum refrigerant charge |
|
g |
|
|
|
150 |
|
|
|
||
Free gas volume in compressor |
|
cm3 |
|
|
|
2360 |
|
|
|
||
Weight without electrical equipment |
kg |
|
|
|
11.7 |
|
|
|
|||
Dimensions |
|
|
|
|
|
|
|
|
|
|
|
Height |
|
mm |
A |
|
|
203 |
|
|
|
||
|
|
|
B |
|
|
197 |
|
|
|
||
|
|
|
B1 |
|
|
|
– |
|
|
|
|
|
|
|
B2 |
|
|
|
– |
|
|
|
|
Suction connector |
location/I.D. mm | angle |
C |
|
|
8.2 | 45° |
|
|
|
|||
|
material | comment |
|
|
Copper | Rubber plug |
|
||||||
Process connector |
location/I.D. mm | angle |
D |
|
|
6.2 | 25° |
|
|
|
|||
|
material | comment |
|
|
Copper | Rubber plug |
|
||||||
Discharge connector |
location/I.D. mm | angle |
E |
|
|
6.2 | 15° |
|
|
|
|||
|
material | comment |
|
|
Copper | Rubber plug |
|
||||||
Oil cooler connector |
location/I.D. mm | angle |
F |
|
|
|
– |
|
|
|
||
|
material | comment |
|
|
|
|
– |
|
|
|
||
Connector tolerance |
I.D. mm |
|
|
|
±0.09 |
|
|
|
|||
Remarks: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S |
= Static cooling normally sufficient |
||||||||||||||||||||||||||
O |
= Oil cooling |
||||||||||||||||||||||||||
F1 |
= Fan cooling 1.5 m/s |
||||||||||||||||||||||||||
|
|
|
|
(compressor compartment temperature |
|||||||||||||||||||||||
|
|
|
|
equal to ambient temperature) |
|||||||||||||||||||||||
F2 |
= Fan cooling 3.0 m/s necessary |
||||||||||||||||||||||||||
SG |
= Suction gas cooling normally sufficent |
–= not applicable in this area
© Danfoss | DCS (CC) | 2015.10 |
DEHC.ED.400.P9.02 | 1 |
EN 12900 LBP |
|
|
|
|
|
220V, 50Hz, fan cooling F2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Evap. temp. in °C |
-45 |
-40 |
-35 |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-6.7 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
20 |
|||||||
Capacity in W |
|
|
|
|
|
410 |
515 |
555 |
639 |
784 |
950 |
1073 |
1140 |
1354 |
1592 |
1706 |
1858 |
|
|
|||||
Power cons. in W |
|
|
|
|
|
297 |
329 |
340 |
362 |
394 |
425 |
444 |
454 |
480 |
501 |
509 |
518 |
|
|
|||||
Current cons. in A |
|
|
|
|
|
2.18 |
2.26 |
2.29 |
2.36 |
2.46 |
2.56 |
2.62 |
2.65 |
2.73 |
2.78 |
2.79 |
2.79 |
|
|
|||||
COP in W/W |
|
|
|
|
|
1.38 |
1.56 |
1.63 |
1.77 |
1.99 |
2.24 |
2.41 |
2.51 |
2.82 |
3.18 |
3.35 |
3.59 |
|
|
|||||
EN 12900 MBP |
|
|
|
|
|
220V, 50Hz, fan cooling F2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Evap. temp. in °C |
-45 |
-40 |
-35 |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-6.7 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
20 |
|||||||
Capacity in W |
|
|
|
|
|
381 |
478 |
516 |
594 |
730 |
886 |
1001 |
1064 |
1265 |
1491 |
1598 |
1742 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power cons. in W |
|
|
|
|
|
306 |
340 |
351 |
374 |
410 |
444 |
466 |
476 |
506 |
533 |
543 |
555 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Current cons. in A |
|
|
|
|
|
2.20 |
2.28 |
2.32 |
2.39 |
2.51 |
2.63 |
2.71 |
2.75 |
2.85 |
2.93 |
2.96 |
2.98 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
COP in W/W |
|
|
|
|
|
1.25 |
1.41 |
1.47 |
1.59 |
1.78 |
2.00 |
2.15 |
2.23 |
2.50 |
2.80 |
2.94 |
3.14 |
|
|
|||||
ASHRAE LBP |
|
|
|
|
|
220V, 50Hz, fan cooling F2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Evap. temp. in °C |
-45 |
-40 |
-35 |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-6.7 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
20 |
|||||||
Capacity in W |
|
|
|
|
|
419 |
522 |
562 |
647 |
795 |
967 |
1095 |
1165 |
1390 |
1644 |
1765 |
1928 |
|
|
|||||
Power cons. in W |
|
|
|
|
|
304 |
341 |
355 |
381 |
421 |
461 |
487 |
500 |
537 |
571 |
585 |
601 |
|
|
|||||
Current cons. in A |
|
|
|
|
|
2.23 |
2.33 |
2.37 |
2.45 |
2.60 |
2.75 |
2.86 |
2.91 |
3.06 |
3.20 |
3.26 |
3.32 |
|
|
|||||
COP in W/W |
|
|
|
|
|
1.38 |
1.53 |
1.58 |
1.70 |
1.89 |
2.10 |
2.25 |
2.33 |
2.59 |
2.88 |
3.02 |
3.21 |
|
|
|||||
ASHRAE MBP/HBP |
|
|
|
|
|
220V, 50Hz, fan cooling F2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Evap. temp. in °C |
-45 |
-40 |
-35 |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-6.7 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
20 |
|||||||
Capacity in W |
|
|
|
|
|
374 |
466 |
502 |
578 |
710 |
863 |
976 |
1038 |
1238 |
1462 |
1569 |
1712 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power cons. in W |
|
|
|
|
|
301 |
338 |
351 |
377 |
417 |
456 |
482 |
495 |
531 |
564 |
578 |
594 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Current cons. in A |
|
|
|
|
|
2.23 |
2.33 |
2.37 |
2.45 |
2.60 |
2.75 |
2.86 |
2.91 |
3.06 |
3.20 |
3.26 |
3.32 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
COP in W/W |
|
|
|
|
|
1.25 |
1.38 |
1.43 |
1.53 |
1.70 |
1.89 |
2.03 |
2.10 |
2.33 |
2.59 |
2.72 |
2.88 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accessories for |
NLE11MN |
Figure |
Code number |
|
|
|
|
ePTC starting device |
6.3 mm spade connectors |
a1 |
– |
|
4.8 mm spade connectors |
103N0050 |
|
|
|
||
Starting relay |
6.3 mm spade connectors |
a2 |
117U7005 |
Start. capacitor 80 µF |
6.3 mm spade connectors |
c |
117U5015 |
Cover |
|
b |
103N2010 |
Cord relief |
|
d |
103N1010 |
Protection screen for PTC |
|
g |
– |
Test conditions |
EN 12900 |
ASHRAE |
||
|
LBP |
MBP |
LBP |
MBP |
Condensing temperature |
40°C |
45°C |
54.4°C |
54.4°C |
Ambient temperature |
32°C |
32°C |
32.2°C |
35°C |
Suction gas temperature |
20°C |
20°C |
32.2°C |
35°C |
Liquid temperature |
no subcooling |
32.2°C |
46.1°C |
Mounting accessories |
|
|
Code number |
Bolt joint for one comp. |
Ø: 16 |
mm |
118-1917 |
Bolt joint in quantities |
Ø: 16 |
mm |
118-1918 |
Snap-on in quantities |
Ø: 16 |
mm |
118-1919 |
© Danfoss | DCS (CC) | 2015.10 |