Danfoss NLE11KK.4 Data sheet

NLE11KK.4
105H
6952
NLE11KK.4
8515-3
DANFOSS COMPRESSORS
Barcode on white background
Yellow background
Red stripe
Approvals
Application
R600a
SUCTION CONNECTOR
8122
R600a
Yellow warning label
70
ø16
254
170
A
B
C
E
D
166
8248
78
54
113
127
47°
27°
51°
119
72
60.
5
25°
35°
15°
93.
5
75.
5
102.
5
100
204
178
205
Energy-optimized Compressor R600a 220-240V 50Hz
General
Code number 105H6952
Approvals EN 60335-2-34 with Annex AA
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 60 (70)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements at max. ambient temperature
Frequency Hz 50 60
Application
32°C S
38°C S
43°C S
Remarks on application:
Motor
Motor type RSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A 4.8
Cut in Current, HST | LST A 9.3
Resistance, main | start winding (25°C)
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 10.8
Dimensions
Height mm A 190
Suction connector location/I.D. mm | angle C 6.2 | 15°
Process connector location/I.D. mm | angle D 6.2 | 25°
Discharge connector location/I.D. mm | angle E 5.0 | 35°
Oil cooler connector location/I.D. mm | angle F
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
June 2004 DEHC.ED.520.C1.02 1/2
LBP MBP HBP LBP MBP HBP
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
material | comment
16.4 15.7
3
3
3
B 183
B1
B2
270 (mineral)
11.15
2310
S = Static cooling normally sucient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sucent – = not applicable in this area
EN 12900 Household (CECOMAF) 220V, 50Hz, 2 W PTC consumption incl., static cooling
8223
N
N
L
C
S
b
d
a1
e
a1
Winding protector
Start winding
Main winding
e
g
pos.2
8217
N
N
L
C
b
d
a1
a1
Winding protector
Start winding
Main winding
g
pos.1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 81.5 109 143 156 184 232 290
Power cons. in W 89.8 105 120 126 137 156 179
Current cons. in A 0.71 0.75 0.80 0.82 0.87 0.95 1.05
COP in W/W 0.91 1.05 1.19 1.24 1.34 1.48 1.62
EN 12900 Household (CECOMAF)
220V, 50Hz, RC 4µF, 2 W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 81.5 109 143 156 184 232 290
Power cons. in W 88.0 102 117 122 133 151 172
Current cons. in A 0.47 0.53 0.60 0.63 0.68 0.77 0.87
COP in W/W 0.93 1.07 1.22 1.28 1.38 1.54 1.69
ASHRAE LBP 220V, 50Hz, 2 W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 99.6 133 175 191 224 284 354
Power cons. in W 89.9 104 120 125 137 156 179
Current cons. in A 0.71 0.75 0.80 0.82 0.87 0.95 1.05
COP in W/W 1.11 1.28 1.46 1.52 1.64 1.82 1.98
ASHRAE LBP
220V, 50Hz, RC 4µF, 2 W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 99.6 133 175 191 224 284 354
Power cons. in W 88.1 102 117 122 133 151 171
Current cons. in A 0.47 0.53 0.60 0.63 0.68 0.77 0.87
COP in W/W 1.13 1.31 1.50 1.56 1.69 1.88 2.06
Accessories Figure Code number Test conditions EN 12900/CECOMAF ASHRAE
PTC starting device 6.3 mm spade connectors
ePTC starting device 4.8 mm spade connectors 103N0050 Suction gas temperature 32°C 32°C
PTC starting device 6.3 mm spade connectors a1 103N0016 Liquid temperature no subcooling 32°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Run capacitor 4 µF (optional)
Protection screen for PTC g 103N0476 Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 DEHC.ED.520.C1.02 June 2004
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
4.8 mm spade connectors (pos.2) 103N0021
6.3 mm spade connectors
4.8 mm spade connectors 117-7119 Bolt joint in quantities Ø : 16 mm 118-1918
a1
(pos.1)
e
103N0011 Condensing temperature 55°C 54.4°C
117-7117 Bolt joint for one compressor Ø : 16 mm 118-1917
Loading...