Danfoss NLE11CNL Data sheet

0 (0)
Danfoss NLE11CNL Data sheet

Datasheets

NLE11CNL Energy-optimized LBP Compressor

R290, 115-127V 60Hz

General

Code number

 

 

 

 

105H5981

 

 

 

Approvals

 

 

 

 

UL984

 

 

 

Compressors on pallet

 

 

 

 

80

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

LBP

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Evaporating temperature

 

°F

 

 

 

-31 to 14

Voltage range

 

V

 

 

 

95 - 135

Max. condensing temperature continuous (short)

°F

 

 

 

149 (149)

Max. winding temperature continuous (short)

°F

 

 

 

257 (275)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Application

 

 

LBP

MBP

HBP

 

LBP

MBP

 

HBP

90°F

 

 

 

F2

 

100°F

 

 

 

F2

 

110°F

 

 

 

F2

 

Remarks on application:

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

CSIR/RSCR

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

28.7

 

 

 

29.9

 

 

Cut in Current, HST | LST

 

A

 

28.7

 

 

 

39.2

 

 

Resistance, main | start winding (77°F)

 

1.10

 

 

 

3.61

 

 

Design

 

 

 

 

 

 

 

 

 

 

Displacement

 

cu.in

 

 

0.68

 

 

 

Oil quantity (type)

 

fl.oz.

 

10.2 (polyolester)

 

Maximum refrigerant charge

 

oz.

 

 

5.3

 

 

 

Free gas volume in compressor

 

fl.oz.

 

 

79.8

 

 

 

Weight without electrical equipment

lbs.

 

 

26.7

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

Height

 

inch

A

 

7.99

 

 

 

 

 

 

B

 

7.76

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

B2

 

 

 

 

 

Suction connector

location, I.D. in. | angle

C

0.320-0.327 | 45°

 

 

 

material | comment

 

Copper | Rubber plug

 

Process connector

location, I.D. in. | angle

D

0.252-0.259 | 25°

 

 

 

material | comment

 

Copper | Rubber plug

 

Discharge connector

location, I.D. in. | angle

E

0.252-0.259 | 15°

 

 

 

material | comment

 

Copper | Rubber plug

 

Oil cooler connector

location, I.D. in. | angle

F

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

This product is approved for R290 regarding explosion

safety according to standard EN 60335-1 and EN

60335-2-34

S

= Static cooling normally sufficient

O

= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

© Danfoss | DCS (CC) | 2017.08

DEHC.ED.100.G1.22 | 1

Loading...
+ 1 hidden pages