Datasheets
NLE11CNL
Energy-optimized LBP Compressor
R290, 115-127V 60Hz
General
Code number 105H5981
Approvals UL984
Compressors on pallet 80
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °F – -31 to 14
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 149 (149)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – F2– –
100°F – – – F
110°F – – – F
Remarks on application:
Motor
Motor type CSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A 28.7 29.9
Cut in Current, HST | LST A 28.7 39.2
Resistance, main | start winding (77°F) Ω 1.10 3.61
Design
Displacement cu.in 0.68
Oil quantity (type) .oz. 10.2 (polyolester)
Maximum refrigerant charge oz. 5.3
Free gas volume in compressor .oz. 79.8
Weight without electrical equipment lbs. 26.7
Dimensions
Height inch A 7.99
Suction connector location, I.D. in. | angle C 0.320-0.327 | 45°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 15°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
– –
2
– –
2
B 7.76
B1 –
B2 –
This product is approved for R290 regarding
explosion
safety according to standard EN 60335-1 and EN
60335-2-34
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
© Danfoss | DCS (CC) | 2017.08
DEHC.ED.100.G1.22 | 1
Danf
already on order pro
All trademarks in this material are property of the respec
ASHRAE LBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in BTU/h 1339 1753 2115 2288 2933 3678 4001
Power cons. in W 301 359 397 413 467 521 543
Current cons. in A 4.10 4.41 4.68 4.80 5.22 5.67 5.85
EER in BTU/Wh 4.45 4.89 5.33 5.53 6.28 7.06 7.37
ASHRAE LBP 115V, 60Hz, RC 23.5 µF, ePTC consumption incl., fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in BTU/h 1370 1793 2162 2337 2991 3746 4074
Power cons. in W 282 336 372 387 437 487 508
Current cons. in A 3.83 4.13 4.38 4.49 4.89 5.31 5.48
EER in BTU/Wh 4.86 5.34 5.82 6.04 6.85 7.69 8.02
EN 12900 LBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in W 399 518 620 667 845 1049 1137
Power cons. in W 314 375 416 433 490 547 571
Current cons. in A 4.10 4.41 4.68 4.80 5.22 5.67 5.85
COP in W/W 1.27 1.38 1.49 1.54 1.73 1.92 1.99
EN 12900 LBP 115V, 60Hz, RC 23.5 µF, ePTC consumption incl., fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in W 399 520 623 671 851 1057 1146
Power cons. in W 294 351 389 405 458 512 534
Current cons. in A 3.83 4.13 4.38 4.49 4.89 5.31 5.48
COP in W/W 1.36 1.48 1.60 1.66 1.86 2.06 2.15
Accessories for NLE11CNL Figure Code number Test conditions
Starting relay 1/4 in. spade connectors a2 117U7020 Condensing temperature 104°F
Start. capacitor 180 µF 1/4 in. spade connectors c 117U5039 Ambient temperature 90°F
ePTC starting device 1/4 in. spade connectors a1 103N0058 Suction gas temperature 68°F
Run capacitor 23.5 µF 1/4 in. spade connectors
(optional)
Cover b 103N2011 Mounting accessories Code number
Cord relief d 103N1010 Bolt joint for one comp. Ø: 3/4 in. 118-1949
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
2 |© Danfoss | DCS (CC) | 2017.08 DEHC.ED.100.G1.22
vided that such alterations can be made without subsequential changes being necessary eady agreed.
e 117-7114
Liquid temperature no subcooling
Bolt joint for one comp. Ø: 5/8 in. 118-1946
Snap-on for one comp. Ø: 5/8 in. 118-1947
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
EN 12900
LBP
ASHRAE
LBP
130°F
90°F
90°F