Datasheets
NLE10MF.2
Energy-optimized LBP/MBP Compressor
R134a, 220-240V 50Hz
General
Code number 105G6187
Approvals EN 60335-2-34 w. Annex AA
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -35 to 10 –
Voltage range V 198 to 254 –
Max. condensing temperature continuous (short) °C 60 (70) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2– – – –
38°C F2F2– – – –
43°C F2F2– – – –
Remarks on application:
Motor
Motor type CSIR/RSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A 11.3 10.7
Cut in Current, HST | LST A 11.3 15.9
Resistance, main | start winding (25°C) Ω 9.0 12.0
LBP MBP HBP LBP MBP HBP
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 600
Free gas volume in compressor cm
Weight without electrical equipment kg 10.9
Dimensions
Height mm A 203
Suction connector location/I.D. mm | angle C 8.2 | 45°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 15°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
320 (polyolester)
B 197
B1 –
B2 –
10.09
2360
© Danfoss | DCS (CC) | 2017.04
DEHC.ED.200.F4.02 | 1
EN 12900 LBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 153 212 281 308 364 463 581 671.6 722 888 1083 1178 1309
Power cons. in W 149 171 195 203 220 246 275 294 305 337 372 387 409
Current cons. in A 1.43 1.46 1.51 1.53 1.57 1.64 1.72 1.78 1.81 1.91 2.01 2.06 2.12
COP in W/W 1.03 1.24 1.45 1.52 1.66 1.88 2.12 2.28 2.37 2.64 2.91 3.04 3.20
2
EN 12900 MBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 131 189 257 282 337 432 545 631 679 838 1024 1115 1240
Power cons. in W 149 173 198 207 225 253 282 303 314 347 383 399 421
Current cons. in A 1.43 1.47 1.52 1.54 1.58 1.66 1.75 1.81 1.85 1.96 2.08 2.13 2.20
COP in W/W 0.88 1.09 1.29 1.36 1.50 1.71 1.93 2.08 2.16 2.41 2.68 2.79 2.95
ASHRAE LBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 116 184 261 290 351 457 584 681 735 914 1125 1229 1372
Power cons. in W 127 157 189 200 221 254 289 313 325 363 402 420 443
Current cons. in A 1.40 1.45 1.51 1.54 1.59 1.69 1.80 1.89 1.93 2.07 2.23 2.30 2.39
COP in W/W 0.92 1.17 1.38 1.45 1.59 1.80 2.02 2.18 2.26 2.52 2.80 2.93 3.10
ASHRAE MBP 220V, 50Hz, fan cooling F
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 104 164 233 258 313 407 520 606 654 813 999 1091 1217
Power cons. in W 126 156 187 198 219 252 286 309 322 359 397 415 437
Current cons. in A 1.40 1.45 1.51 1.54 1.59 1.69 1.80 1.86 1.93 2.07 2.23 2.30 2.39
COP in W/W 0.83 1.05 1.24 1.31 1.43 1.62 1.82 1.96 2.03 2.27 2.52 2.63 2.78
2
2
2
Accessories for NLE10MF.2 Figure Code number Test conditions
ePTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0050 Ambient temperature 32°C 32°C 32.2°C 35°C
Starting relay 6.3 mm spade connectors a2 117U6002 Suction gas temperature 20°C 20°C 32.2°C 35°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature no subcooling 32.2°C 46.1°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
a1
– Condensing temperature 40°C 45°C 54.4°C 54.4°C
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
© Danfoss | DCS (CC) | 2017.04
EN 12900
LBP MBP
DEHC.ED.200.F4.02 | 2
ASHRAE
LBP MBP