Danfoss NLE10MF.2 Data sheet

Danfoss NLE10MF.2 Data sheet

Datasheets

NLE10MF.2 Energy-optimized LBP/MBP Compressor

R134a, 220-240V 50Hz

General

Code number

 

 

 

 

 

105G6187

 

 

 

Approvals

 

 

EN 60335-2-34 w. Annex AA

Compressors on pallet

 

 

 

 

 

80

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

LBP/MBP

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Evaporating temperature

 

°C

-35 to 10

 

 

 

Voltage range

 

V

198 to 254

 

 

 

Max. condensing temperature continuous (short)

°C

 

60 (70)

 

 

 

Max. winding temperature continuous (short)

°C

125 (135)

 

 

 

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

MBP

 

HBP

32°C

 

 

F2

 

F2

 

 

38°C

 

 

F2

 

F2

 

 

43°C

 

 

F2

 

F2

 

 

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

CSIR/RSIR/RSCR

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

11.3

 

 

 

10.7

 

 

Cut in Current, HST | LST

 

A

 

11.3

 

 

 

15.9

 

 

Resistance, main | start winding (25°C)

 

9.0

 

 

 

12.0

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cm3

 

 

 

10.09

 

 

 

Oil quantity (type)

 

cm3

 

 

320 (polyolester)

 

Maximum refrigerant charge

 

g

 

 

 

600

 

 

 

Free gas volume in compressor

 

cm3

 

 

 

2360

 

 

 

Weight without electrical equipment

kg

 

 

 

10.9

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

mm

A

 

 

203

 

 

 

 

 

 

B

 

 

197

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

 

B2

 

 

 

 

 

 

Suction connector

location/I.D. mm | angle

C

 

 

8.2 | 45°

 

 

 

 

material | comment

 

 

Copper | Rubber plug

 

Process connector

location/I.D. mm | angle

D

 

 

6.2 | 25°

 

 

 

 

material | comment

 

 

Copper | Rubber plug

 

Discharge connector

location/I.D. mm | angle

E

 

 

6.2 | 15°

 

 

 

 

material | comment

 

 

Copper | Rubber plug

 

Oil cooler connector

location/I.D. mm | angle

F

 

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

 

Connector tolerance

I.D. mm

 

 

 

±0.09

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

= Static cooling normally sufficient

O

= Oil cooling

F1

= Fan cooling 1.5 m/s

 

 

 

 

 

(compressor compartment temperature

 

 

 

 

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

© Danfoss | DCS (CC) | 2017.04

DEHC.ED.200.F4.02 | 1

EN 12900 LBP

 

 

 

 

 

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

 

-10

-6.7

-5

0

5

7.2

 

10

15

20

 

Capacity in W

 

 

 

 

153

212

281

308

 

364

463

 

581

671.6

722

888

1083

1178

 

1309

 

 

 

Power cons. in W

 

 

 

 

149

171

195

203

 

220

246

 

275

294

305

337

372

387

 

409

 

 

 

Current cons. in A

 

 

 

 

1.43

1.46

1.51

1.53

 

1.57

1.64

 

1.72

1.78

1.81

1.91

2.01

2.06

 

2.12

 

 

 

COP in W/W

 

 

 

 

1.03

1.24

1.45

1.52

 

1.66

1.88

 

2.12

2.28

2.37

2.64

2.91

3.04

 

3.20

 

 

 

EN 12900 MBP

 

 

 

 

 

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

 

-10

-6.7

-5

0

5

7.2

 

10

15

20

 

Capacity in W

 

 

 

 

131

189

257

282

 

337

432

 

545

631

679

838

1024

1115

 

1240

 

 

 

Power cons. in W

 

 

 

 

149

173

198

207

 

225

253

 

282

303

314

347

383

399

 

421

 

 

 

Current cons. in A

 

 

 

 

1.43

1.47

1.52

1.54

 

1.58

1.66

 

1.75

1.81

1.85

1.96

2.08

2.13

 

2.20

 

 

 

COP in W/W

 

 

 

 

0.88

1.09

1.29

1.36

 

1.50

1.71

 

1.93

2.08

2.16

2.41

2.68

2.79

 

2.95

 

 

 

ASHRAE LBP

 

 

 

 

 

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

 

-10

-6.7

-5

0

5

7.2

 

10

15

20

 

Capacity in W

 

 

 

 

116

184

261

290

 

351

457

 

584

681

735

914

1125

1229

 

1372

 

 

 

Power cons. in W

 

 

 

 

127

157

189

200

 

221

254

 

289

313

325

363

402

420

 

443

 

 

 

Current cons. in A

 

 

 

 

1.40

1.45

1.51

1.54

 

1.59

1.69

 

1.80

1.89

1.93

2.07

2.23

2.30

 

2.39

 

 

 

COP in W/W

 

 

 

 

0.92

1.17

1.38

1.45

 

1.59

1.80

 

2.02

2.18

2.26

2.52

2.80

2.93

 

3.10

 

 

 

ASHRAE MBP

 

 

 

 

 

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

 

-10

-6.7

-5

0

5

7.2

 

10

15

20

 

Capacity in W

 

 

 

 

104

164

233

258

 

313

407

 

520

606

654

813

999

1091

 

1217

 

 

 

Power cons. in W

 

 

 

 

126

156

187

198

 

219

252

 

286

309

322

359

397

415

 

437

 

 

 

Current cons. in A

 

 

 

 

1.40

1.45

1.51

1.54

 

1.59

1.69

 

1.80

1.86

1.93

2.07

2.23

2.30

 

2.39

 

 

 

COP in W/W

 

 

 

 

0.83

1.05

1.24

1.31

 

1.43

1.62

 

1.82

1.96

2.03

2.27

2.52

2.63

 

2.78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories for

NLE10MF.2

Figure

Code number

 

 

 

 

ePTC starting device

6.3 mm spade connectors

a1

 

4.8 mm spade connectors

103N0050

 

 

Starting relay

6.3 mm spade connectors

a2

117U6002

Start. capacitor 80 µF

6.3 mm spade connectors

c

117U5015

Cover

 

b

103N2010

Cord relief

 

d

103N1010

Protection screen for PTC

 

g

Test conditions

EN 12900

ASHRAE

 

LBP

MBP

LBP

MBP

Condensing temperature

40°C

45°C

54.4°C

54.4°C

Ambient temperature

32°C

32°C

32.2°C

35°C

Suction gas temperature

20°C

20°C

32.2°C

35°C

Liquid temperature

no subcooling

32.2°C

46.1°C

Mounting accessories

 

 

Code number

Bolt joint for one comp.

Ø: 16

mm

118-1917

Bolt joint in quantities

Ø: 16

mm

118-1918

Snap-on in quantities

Ø: 16

mm

118-1919

© Danfoss | DCS (CC) | 2017.04

DEHC.ED.200.F4.02 | 2