Danfoss NL9F Data sheet

NL9F Standard Compressor R134a 220-240V 50Hz
General
Code number 105G6802
Approvals EN 60335-2-34 with Annex AA
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 60 (70)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C
38°C
43°C – Remarks on application:
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 7.9 6.6
Cut in Current, HST | LST A 7.9 10.9
Resistance, main | start winding (25°C) 10.7 13.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 10.0
Dimensions
Height mm A 197
Suction connector location/I.D. mm | angle C 8.2 | 15°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 35°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
S
S
3
3
3
B 191
B1
B2
8.35
320 (polyolester)
2280
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.Q2.02 / 520N1336 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 74 111 155 172 207 268 340
Power cons. in W 109 139 167 176 195 226 260
Current cons. in A 0.89 0.97 1.07 1.11 1.18 1.29 1.42
COP in W/W 0.68 0.80 0.93 0.97 1.06 1.19 1.31
ASHRAE LBP 220V, 50Hz, static cooling
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 92 138 192 213 256 332 421
Power cons. in W 110 139 167 176 195 225 259
Current cons. in A 0.89 0.97 1.07 1.10 1.18 1.29 1.41
COP in W/W 0.84 0.99 1.15 1.21 1.32 1.48 1.63
Accessories for NL9F Figure Code number Test conditions EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 54.4°C
Starting relay 6.3 mm spade connectors a2 117U6001 Suction gas temperature 32°C 32°C
Start capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature no subcooling 32°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.Q2.02 / 520N1336 June 2012