Datasheets
NL7CLX
LBP/MBP Compressor
R404A/R507, 220-240V 50Hz
General
Code number 105F3710
Approvals EN 60335-2-34, CCC, UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -45 to -5 –
Voltage range V 198 - 254 –
Max. condensing temperature continuous (short) °C 50 (60) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C F1F1– – – –
38°C F
43°C F
Remarks on application:
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 10.4 9.2
Cut in Current, HST | LST A 10.4 13.6
Resistance, main | start winding (25°C) Ω 8.2 14.7
LBP MBP HBP LBP MBP HBP
1F1
2F2
– – – –
– – – –
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 10.5
Dimensions
Height mm A 203
Suction connector location/I.D. mm | angle C 8.2 | 15°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
320 (polyolester)
B 197
B1 –
B2 –
7.27
2360
© Danfoss | DCS (CC) | 2017.02
DEHC.ED.200.B1.02 | 1

EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
Danf
already on order pro
All trademarks in this material are property of the respec
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 102 146 199 263 340 369 430 536 657 746 796
Power cons. in W 158 186 214 243 274 284 306 342 381 410 426
Current cons. in A 1.31 1.38 1.46 1.56 1.68 1.72 1.81 1.96 2.13 2.25 2.32
COP in W/W 0.65 0.78 0.93 1.08 1.24 1.30 1.41 1.57 1.72 1.82 1.87
ASHRAE LBP* 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 120 171 234 309 399 433 505 628 770 875 933
Power cons. in W 158 186 213 241 270 281 302 337 375 403 419
Current cons. in A 1.32 1.38 1.46 1.55 1.67 1.71 1.80 1.94 2.10 2.22 2.28
COP in W/W 0.76 0.92 1.10 1.28 1.48 1.54 1.67 1.87 2.05 2.17 2.23
Accessories for NL7CLX Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 45°C 43.3°C
EN 12900/CECOMAF
ASHRAE LBP*
Starting relay 6.3 mm spade connectors a2 117U6002 Suction gas temperature 32°C 32°C
Cover b 103N2010 Liquid temperature no subcooling 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.02 DEHC.ED.200.B1.02