Datasheets
NL7.3MF
Standard Compressor
R134a, 220-240V 50Hz & 208-230V 60Hz
General
Code number 105G6772
Approvals EN 60335-2-34, UL984
Compressors on pallet 80
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -20 to 15 -35 to 7.2
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C – F1F1F1F1–
38°C – F
43°C – F
Remarks on application:
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 11.3 8.8
Cut in Current, HST | LST A 11.3 12.9
Resistance, main | start winding (25°C) Ω 8.3 17.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 600
Free gas volume in compressor cm
Weight without electrical equipment kg 10.5
Dimensions
Height mm A 197
Suction connector location/I.D. mm | angle C 8.2 | 15°
Process connector location/I.D. mm | angle D 6.2 | 25°
Discharge connector location/I.D. mm | angle E 6.2 | 35°
Oil cooler connector location/I.D. mm | angle F –
Connector tolerance I.D. mm ±0.09
Remarks:
F2 for 230-240V 50Hz nominal below -12°C evaporating temp.
CSIR strongly recommended for 60Hz
material | comment Copper | Rubber plug
material | comment Copper | Rubber plug
material | comment Copper | Rubber plug
material | comment –
LBP MBP HBP LBP MBP HBP
1F1F1F1
1F1F1F1
3
3
3
B 191
B1 –
B2 –
7.27
320 (polyolester)
2360
S =Staticcoolingnormallysufcient
O = Oil cooling
–
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
–
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
© Danfoss | DCS (CC) | 2017.02
DEHC.ED.200.C6.02 | 1
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
Danf
already on order pro
All trademarks in this material are property of the respec
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 179 236 304 356 385 480 591 645 719 867
Power cons. in W 181 204 227 242 250 274 298 310 325 352
Current cons. in A 1.57 1.61 1.67 1.71 1.74 1.82 1.91 1.96 2.02 2.14
COP in W/W 0.99 1.16 1.34 1.47 1.54 1.75 1.98 2.08 2.21 2.46
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 73 113 159 177 216 283 363 424 458 570 700 763
Power cons. in W 110 141 174 185 207 241 275 298 310 344 379 394
Current cons. in A 1.11 1.20 1.30 1.34 1.41 1.53 1.66 1.75 1.80 1.94 2.09 2.16
COP in W/W 0.67 0.80 0.92 0.96 1.04 1.17 1.32 1.42 1.48 1.65 1.85 1.93
ASHRAE MBP 220V, 50Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 198 261 336 393 425 530 652 712 794 958
Power cons. in W 181 204 226 241 249 273 297 308 323 351
Current cons. in A 1.57 1.61 1.67 1.71 1.74 1.82 1.91 1.95 2.02 2.14
COP in W/W 1.09 1.28 1.49 1.63 1.71 1.94 2.19 2.31 2.46 2.73
ASHRAE MBP 220V, 60Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 82 125 177 197 239 313 402
Power cons. in W 111 142 174 185 207 240 274
Current cons. in A 1.11 1.20 1.30 1.34 1.41 1.53 1.66
COP in W/W 0.74 0.88 1.02 1.06 1.15 1.30 1.47
469 506 630 773 844
297 308 343 377 392
1.74 1.79 1.93 2.09 2.15
1.58 1.64 1.84 2.05 2.15
Accessories for NL7.3MF Figure Code number Test conditions
EN 12900/
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 35°C
a1
103N0011 Condensing temperature 55°C 54.4°C
Starting relay 6.3 mm spade connectors a2 117U6016 Suction gas temperature 32°C 35°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature no subcooling 46.1°C
Cover b 103N2011
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.02 DEHC.ED.200.C6.02
ASHRAE