Datasheets
NL7.3CNX.2
LBP/MBP Compressor
R290
115V 60Hz
General
Code number 105H6790
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -40 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 131 (149)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – F2F2–
100°F – – – F
110°F – – – F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 26.4 –
Cut in Current, HST | LST A 26.4 –
Resistance, main | start winding (77°F) Ω 1.3 7.0
LBP MBP HBP LBP MBP HBP
2F2
2F2
S = Static cooling normally sufcient
O = Oil cooling
–
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
–
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Design
Displacement cu.in 0.44
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 5.3
Free gas volume in compressor .oz. 78.1
Weight without electrical equipment lbs. 23.1
Dimensions
Height inch A 7.99
B 7.76
B1 –
B2 –
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
© Danfoss | DCS (CC) | 2016.11
DEHC.ED.540.A3.22| 1
ASHRAE LBP 115V, 60Hz, fan cooling F
Danf
already on order pro
All trademarks in this material are property of the respec
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in BTU/h 579 824 1123 1369 1485 1920 2440 2673 3053 3772 3929 3929 4607 5071
Power cons. in W 180 218 255 280 290 325 361 376 399 439 447 447 482 505
Current cons. in A 3.30 3.44 3.61 3.75 3.82 4.06 4.33 4.45 4.63 4.97 5.04 5.04 5.34 5.54
EER in BTU/Wh 3.23 3.78 4.41 4.90 5.12 5.90 6.75 7.11 7.65 8.59 8.78 8.78 9.55 10.04
ASHRAE MBP/HBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in BTU/h 523 744 1014 1236 1340 1733 2200 2411 2753 3398 3540 4148 4229 4564
Power cons. in W 180 218 255 280 290 325 361 376 399 439 447 482 487 505
Current cons. in A 3.30 3.44 3.61 3.75 3.82 4.06 4.33 4.45 4.63 4.97 5.04 5.34 5.38 5.54
EER in BTU/Wh 2.91 3.41 3.98 4.42 4.62 5.32 6.09 6.41 6.90 7.74 7.91 8.60 8.69 9.03
EN 12900 Household (CECOMAF)* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in W 157 229 315 385 418 539 682 745 847 1039 1080 1258 1281 1379
Power cons. in W 179 213 245 267 276 307 338 351 371 407 414 445 450 466
Current cons. in A 3.35 3.45 3.58 3.69 3.74 3.94 4.17 4.27 4.43 4.73 4.79 5.06 5.09 5.23
COP in W/W 0.87 1.07 1.29 1.44 1.51 1.76 2.02 2.12 2.28 2.55 2.61 2.82 2.85 2.96
Accessories for NL7.3CNX.2 Figure Code number Test conditions
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. – Ambient temp.
a1
– Condensing temp.
Starting relay 1/4 in. spade connect. a2 117U7013 Suction gas temp.
Cover b 103N2011 Liquid temperature
ASHRAE
LBP
ASHRAE
MBP/HBP
130°F 130°F
90°F 90°F
90°F 95°F
90°F 115°F
Start. capacitor 125 µF 1/4 in. spade connect. c 117U5035
Cord relief d 103N1010 Mounting accessories Code number
Bolt joint for one comp. Ø: 5/8 in. 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2016.11 DEHC.ED.540.A3.22
EN 12900/
CECOMAF*
113°F
90°F
90°F
no subcooling