Danfoss NL6FT Data sheet

NL6FT Tropical Compressor R134a 220-240V 50/60Hz
General
Code number 105G6628
Approvals EN 60335-2-34, CCC
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10 -35 to -10
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S
38°C S
43°C S – Remarks on application: In capillary tube systems where non-equalized pressures may
occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 7.4 5.9
Cut in Current, HST | LST A 7.4 10.3
Resistance, main | start winding (25°C) 12.6 12.4
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 10.0
Dimensions
Height mm A 197
Suction connector location/I.D. mm | angle C 6.2 | 15°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 35°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 191
B1
B2
6.13
320
2360
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.M1.02 / 520N1332 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling, PTC consumption incl.
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 60 84 115 127 152 198 253
Power cons. in W 93 107 123 130 142 163 184
Current cons. in A 0.77 0.80 0.84 0.85 0.89 0.96 1.04
COP in W/W 0.65 0.79 0.93 0.98 1.07 1.22 1.37
ASHRAE LBP 220V, 50Hz, static cooling, PTC consumption incl.
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 74 104 141 156 188 244 311
Power cons. in W 93 107 123 130 142 163 184
Current cons. in A 0.77 0.80 0.84 0.85 0.89 0.96 1.04
COP in W/W 0.80 0.97 1.15 1.21 1.32 1.50 1.69
Accessories for NL6FT Figure Code number Test conditions EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 55°C
Starting relay 6.3 mm spade connectors a2 117U6000 Suction gas temperature 32°C 32°C
Start capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature no subcooling 32°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø : 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.M1.02 / 520N1332 June 2012
Loading...