Datasheets
NL6.1MLX
MBP Compressor
R404A/R507, 220-240V 50Hz & 208-230V 60Hz
General
Code number 105F3611
Approvals EN 60335-2-34, UL984
Compressors on pallet 80
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -23.3 to 7.2 -23.3 to 7.2
Voltage range V 187 - 254 187 - 254
Max. condensing temperature continuous (short) °C 55 (60) 55 (60)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C – F2– – F2–
38°C – F
43°C – F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 16.6 –
Cut in Current, HST | LST A 16.6 –
Resistance, main | start winding (25°C) Ω 6.1 17.5
LBP MBP HBP LBP MBP HBP
– – F2–
2
– – F2–
2
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 10.5
Dimensions
Height mm A 203
Suction connector location/I.D. mm | angle C 8.2 | 15°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.5 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.5 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
320 (polyolester)
B 197
B1 –
B2 –
6.13
2310
© Danfoss | DCS (CC) | 2017.02
DEHC.ED.200.C5.02 | 1

ASHRAE MBP 230V, 60Hz, fan cooling F
Danf
already on order pro
All trademarks in this material are property of the respec
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 298 359 462 580
Power cons. in W 282 310 352 392
Current cons. in A 1.89 1.99 2.14 2.29
COP in W/W 1.06 1.16 1.31 1.48
668 717 873 1052 1139
419 432 471 508 525
2.39 2.45 2.61 2.77 2.84
1.60 1.66 1.86 2.07 2.17
EN 12900 Household (CECOMAF) 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 339 401 507 630 720 771 932 111 6 1205
Power cons. in W 276 300 334 368 389 400 431 462 476
Current cons. in A 1.88 1.96 2.08 2.20 2.29 2.33 2.46 2.60 2.66
COP in W/W 1.23 1.34 1.52 1.71 1.85 1.93 2.16 2.42 2.53
ASHRAE MBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 248 299 387 488 562 603 736 888 962
Power cons. in W 255 275 305 334 352 362 388 412 422
Current cons. in A 2.18 2.22 2.30 2.38 2.43 2.46 2.55 2.64 2.68
COP in W/W 0.97 1.09 1.27 1.46 1.59 1.67 1.90 2.16 2.28
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 281 334 425 530 608 650 789 946 1022
Power cons. in W 244 261 287 312 327 335 356 375 383
Current cons. in A 2.12 2.16 2.22 2.29 2.33 2.36 2.43 2.50 2.54
COP in W/W 1.16 1.28 1.48 1.70 1.86 1.94 2.22 2.52 2.67
Accessories for NL6.1MLX Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors – Ambient temperature 32°C 35°C
a1
– Condensing temperature 45°C 54.4°C
EN 12900/CECOMAF
ASHRAE MBP
Starting relay 6.3 mm spade connectors a2 117U6022 Suction gas temperature 32°C 35°C
Cover (UL approved) b 103N2011 Liquid temperature no subcooling 46.1°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.02 DEHC.ED.200.C5.02