Danfoss NL6.1MF Data sheet

Datasheets
NL6.1MF
Standard Compressor
R134a, 220-240V 50Hz & 208-230V 60Hz
General
Code number 105G6660
Approvals EN 60335-2-34, UL984
Compressors on pallet 80
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -20 to 15 -35 to 7.2
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F1F1F1F1–
38°C F
43°C F
Remarks on application:
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 9.2 8.0
Cut in Current, HST | LST A 9.2 12.2
Resistance, main | start winding (25°C) 10.2 16.4
F2 for 230-240V 50Hz nominal below -12°C evaporating temp.
CSIR strongly recommended for 60Hz
LBP MBP HBP LBP MBP HBP
1F1F1F1
1F1F1F1
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 600
Free gas volume in compressor cm
Weight without electrical equipment kg 10.5
Dimensions
Height mm A 190
Suction connector location/I.D. mm | angle C 8.2 | 15°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
320 (polyolester)
B 184
B1
B2
6.13
2360
© Danfoss | DCS (CC) | 2017.02
DEHC.ED.200.C2.02 | 1
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
Danf already on order pro All trademarks in this material are property of the respec
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 141 189 245 288 312 390 482 527 588 709
Power cons. in W 150 169 187 200 206 224 243 252 263 283
Current cons. in A 1.35 1.39 1.43 1.46 1.48 1.54 1.60 1.63 1.67 1.75
COP in W/W 0.94 1.12 1.31 1.44 1.51 1.74 1.98 2.09 2.24 2.51
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 43 77 11 7 132 165 223 292 344 374 470 581 636
Power cons. in W 78 105 132 141 160 189 218 237 247 276 306 319
Current cons. in A 0.91 0.99 1.08 1.11 1.17 1.26 1.37 1.44 1.48 1.60 1.73 1.78
COP in W/W 0.55 0.73 0.89 0.94 1.03 1.18 1.34 1.45 1.51 1.70 1.90 2.00
ASHRAE MBP 220V, 50Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 156 209 271 318 345 432 533 582 650 784
Power cons. in W 150 168 187 199 205 224 242 251 261 281
Current cons. in A 1.35 1.39 1.43 1.46 1.48 1.54 1.60 1.63 1.67 1.75
COP in W/W 1.04 1.24 1.45 1.60 1.68 1.93 2.20 2.32 2.48 2.78
ASHRAE MBP 220V, 60Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 49 86 130 147 183 247 323
Power cons. in W 79 105 132 142 160 188 217
Current cons. in A 0.92 0.99 1.08 1.11 1.17 1.26 1.37
COP in W/W 0.62 0.82 0.98 1.04 1.15 1.31 1.49
381 414 520 643 703
236 246 275 304 317
1.44 1.48 1.60 1.72 1.78
1.62 1.68 1.89 2.12 2.22
Accessories for NL6.1MF Figure Code number Test conditions
EN 12900/
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 35°C
a1
103N0011 Condensing temperature 55°C 54.4°C
Starting relay 6.3 mm spade connectors a2 117U6015 Suction gas temperature 32°C 35°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature no subcooling 46.1°C
Cover b 103N2011
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.02 DEHC.ED.200.C2.02
ASHRAE