Compressors
Standard Compressor R134a 220-240V 50Hz
Data Sheet (Replaces CG.43.J1.02)
General
Compressor NL11F Code number 105G6900 Code number 105G6901* Code number compressor with oil cooler 105G6910
*) Performance data established on 8.2 mm
suction line. Restrictions due to 6.2 mm
Application
Application LBP Evaporating temperature range °C -35 to -10 Voltage range V/Hz 198 - 254 /50 Motor type RSIR/CSIR Max. ambient temperature °C 38 Comp. cooling at ambient temp. 32°C O/F
suction line can affect system performance.
1
1
Application
)
Blue stripe Approvals Barcode on
white background Yellow background
NL11F
R134a
6900
DANFOSS COMPRESSORS
S = Static cooling normally sufficient O = Oil cooling F1= Fan cooling 1.5 m/s
(compressor compartment temperature equal to ambient temperature)
F2= Fan cooling 3.0 m/s necessary
105G
8273-6
Design
Displacement cm Oil quantity cm Maximum refrigerant charge g 400 Free gas vol. in compressor cm Weight without electrical equipment kg 10.7
3
3
3
11.15 320
2360
Motor
Motor size watt 235 LRA (rated after 4 sec. UL984) LST/HST A 9.2/10.4 Cut-in current LST/HST A 13.6/10.4 Resistance, main and start winding (25°C) 8.2/14.7 Approvals EN 60335-2-34 with Annex AA
Dimensions 105G6910 105G6900 105G6901
Height mm A 203
Suction connector location/I.D. mm C 8.2 ±0.09 8.2 ±0.09 6.2 ±0.09 Process connector location/I.D. mm D 6.2 ±0.09 6.2 ±0.09 6.2 ±0.09 Discharge connector location/I.D. mm E 6.2 ±0.09 6.2 ±0.09 5.0 +0.12/+0.20 Oil cooler location/I.D. mm F 6.2 ±0.09 Compressors on a pallet pcs. 80
B 197
August 2001 CG.43.J2.02 1
Capacity (EN 12900/CECOMAF) watt
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material.Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
C°\.pmoC53-03-52-3.32-02-51-01-
F11LN201441002322172653554
Capacity (ASHRAE) watt
C°\.pmoC53-03-52-3.32-02-51-01-
F11LN521771642472433834165
Power consumption watt
C°\.pmoC53-03-52-3.32-02-51-01-
F11LN641871212422842682523
Current consumption A
C°\.pmoC53-03-52-3.32-02-51-01-
F11LN04.164.145.175.146.157.198.1
COP (EN 12900/CECOMAF) W/W
C°\.pmoC53-03-52-3.32-02-51-01-
F11LN07.018.049.099.090.152.104.1
COP (ASHRAE) W/W
C°\.pmoC53-03-52-3.32-02-51-01-
F11LN68.099.061.122.143.135.137.1
Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, 220V 50Hz, PTC consumption incl.
HST
b
Main winding
LST
c
10
Winding protector
g
8219
a2
d
c
11
1312
14
Start winding
Accessories
seciveD.giFF11LN
sedapsmm3.6ecivedgnitratsCTP sedapsmm8.4
yalergnitratS2a2006U711
revoCb0102N301
08roticapacgnitratS µFc 5105U711
feilerdroCd0101N301
CTProfneercsnoitcetorPg6740N301
seirosseccagnitnuoM
rosserpmocenoroftniojtloB seititnauqnitniojtloB seititnauqnino-panS
b
8217
a1
d
1a
1100N301 8100N301
Main winding
N
N
Start winding
a1
C
L
7191-811 8191-811
Winding protector
9191-811
2 CG.43.J2.02 August 2001