NL10FT
Tropical Compressor
R134a
220-240V 50Hz
General
Code number |
|
|
|
|
|
105G6829 |
|
|
||
Approvals |
|
|
|
|
EN 60335-2-34, CCC |
|
||||
Compressors on pallet |
|
|
|
|
|
80 |
|
|
||
Application |
|
|
|
|
|
|
|
|
|
|
Application |
|
|
|
|
|
LBP |
|
|
||
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
Evaporating temperature |
|
°C |
-35 to -10 |
|
|
– |
|
|||
Voltage range |
|
V |
187 - 254 |
|
|
– |
|
|||
Max. condensing temperature continuous (short) |
°C |
|
60 (70) |
|
|
– |
|
|||
Max. winding temperature continuous (short) |
°C |
125 (135) |
|
|
– |
|
||||
Cooling requirements |
|
|
|
|
|
|
|
|
|
|
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
Application |
|
|
LBP |
|
MBP |
HBP |
|
LBP |
MBP |
HBP |
32°C |
|
|
S |
|
– |
– |
|
– |
– |
– |
38°C |
|
|
F1 |
|
– |
– |
|
– |
– |
– |
43°C |
|
|
F1 |
|
– |
– |
|
– |
– |
– |
Remarks on application: In capillary tube systems where non-equalized pressures may |
||||||||||
occur at compressor start, or in areas with short power supply drop-outs, a starting |
|
|||||||||
capacitor can be used for ensuring a successful start (CSIR). |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
Motor |
|
|
|
|
|
|
|
|
|
|
Motor type |
|
|
|
|
|
RSIR |
|
|
||
LRA (rated after 4 sec. UL984), HST | LST |
A |
|
10.4 |
|
|
|
9.2 |
|
||
Cut in Current, HST | LST |
|
A |
|
10.4 |
|
|
|
13.6 |
|
|
Resistance, main | start winding (25°C) |
Ω |
|
8.2 |
|
|
|
14.7 |
|
||
Design |
|
|
|
|
|
|
|
|
|
|
Displacement |
|
cm3 |
|
|
|
10.10 |
|
|
||
Oil quantity (type) |
|
cm3 |
|
|
|
320 |
|
|
||
Maximum refrigerant charge |
|
g |
|
|
|
400 |
|
|
||
Free gas volume in compressor |
|
cm3 |
|
|
|
2360 |
|
|
||
Weight without electrical equipment |
kg |
|
|
|
10.5 |
|
|
|||
Dimensions |
|
|
|
|
|
|
|
|
|
|
Height |
|
mm |
A |
|
|
203 |
|
|
||
|
|
|
B |
|
|
197 |
|
|
||
|
|
|
B1 |
|
|
|
– |
|
|
|
|
|
|
B2 |
|
|
|
– |
|
|
|
Suction connector |
location/I.D. mm | angle |
C |
|
|
8.2 | 15° |
|
|
|||
|
material | comment |
|
Cu-plated steel | Al cap |
|||||||
Process connector |
location/I.D. mm | angle |
D |
|
|
6.2 | 25° |
|
|
|||
|
material | comment |
|
Cu-plated steel | Al cap |
|||||||
Discharge connector |
location/I.D. mm | angle |
E |
|
|
6.2 | 35° |
|
|
|||
|
|
|
|
|||||||
|
material | comment |
|
Cu-plated steel | Al cap |
|||||||
|
|
|
|
|
|
|
|
|
||
Oil cooler connector |
location/I.D. mm | angle |
F |
|
|
|
– |
|
|
||
|
material | comment |
|
|
|
|
– |
|
|
||
|
|
|
||||||||
Connector tolerance |
I.D. mm |
±0.09, on 5.0 +0.12/+0.20 |
||||||||
Remarks: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S = Static cooling normally sufficient
O= Oil cooling
F1 |
= Fan cooling 1.5 m/s |
|
(compressor compartment temperature |
|
equal to ambient temperature) |
F2 |
= Fan cooling 3.0 m/s necessary |
SG |
= Suction gas cooling normally sufficent |
–= not applicable in this area
June 2012 |
Manufactured by Secop for Danfoss - DEHC.ED.401.I5.02 / 520N1338 |
1/2 |