Datasheets
NF7MLX MBP Compressor
R404A/R507, 220-240V 50Hz & 208-230V 60Hz
General
Code number |
|
|
|
|
105F3721 |
|
|||
Approvals |
|
|
|
EN 60335-2-34 |
|
||||
Compressors on pallet |
|
|
|
|
80 |
|
|
|
|
Application |
|
|
|
|
|
|
|
|
|
Application |
|
|
|
|
MBP |
|
|
|
|
Frequency |
Hz |
|
50 |
|
|
60 |
|
||
Evaporating temperature |
°C |
|
-15 to 10 |
-23.3 to 7.2 |
|||||
Voltage range |
V |
|
187 - 254 |
187 - 254 |
|||||
Max. condensing temperature continuous (short) |
°C |
|
55 (60) |
|
55 (60) |
||||
Max. winding temperature continuous (short) |
°C |
|
125 (135) |
125 (135) |
|||||
Cooling requirements |
|
|
|
|
|
|
|
|
|
Frequency |
Hz |
|
50 |
|
|
60 |
|
||
Application |
|
LBP |
MBP |
HBP |
LBP |
|
MBP |
HBP |
|
32°C |
|
– |
|
F2 |
– |
– |
|
F2 |
– |
38°C |
|
– |
|
F2 |
– |
– |
|
F2 |
– |
43°C |
|
– |
|
F2 |
– |
– |
|
F2 |
– |
Remarks on application: 220V 50Hz nominal below -10°C evaporating temperature |
|
||||||||
|
|
|
|
|
|
|
|
|
|
Motor |
|
|
|
|
|
|
|
|
|
Motor type |
|
|
|
|
CSIR |
|
|
|
|
LRA (rated after 4 sec. UL984), HST | LST |
A |
|
21.0 |
|
|
|
– |
|
|
Cut in Current, HST | LST |
A |
|
21.0 |
|
|
|
– |
|
|
Resistance, main | start winding (25°C) |
Ω |
|
4.5 |
|
|
12.8 |
|
||
Design |
|
|
|
|
|
|
|
|
|
Displacement |
cm3 |
|
|
|
7.27 |
|
|
|
|
Oil quantity (type) |
cm3 |
|
|
320 (polyolester) |
|
||||
Maximum refrigerant charge |
g |
|
|
|
400 |
|
|
|
|
Free gas volume in compressor |
cm3 |
|
|
|
2310 |
|
|
|
|
Weight without electrical equipment |
kg |
|
|
|
10.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S |
|
= Static cooling normally sufficient |
||||||||||||||||||||||||||||||
O |
|
= Oil cooling |
||||||||||||||||||||||||||||||
F1 |
|
= Fan cooling 1.5 m/s |
||||||||||||||||||||||||||||||
|
|
|
(compressor compartment temperature |
|||||||||||||||||||||||||||||
|
|
|
equal to ambient temperature) |
|||||||||||||||||||||||||||||
F2 |
|
= Fan cooling 3.0 m/s necessary |
||||||||||||||||||||||||||||||
SG |
|
= Suction gas cooling normally sufficent |
–= not applicable in this area
Dimensions |
|
|
|
Height |
mm |
A |
203 |
|
|
B |
197 |
|
|
B1 |
– |
|
|
B2 |
– |
Suction connector |
location/I.D. mm | angle |
C |
8.2 | 15° |
|
material | comment |
|
Copper | Rubber plug |
Process connector |
location/I.D. mm | angle |
D |
6.2 | 25° |
|
material | comment |
|
Copper | Rubber plug |
Discharge connector |
location/I.D. mm | angle |
E |
6.2 | 35° |
|
material | comment |
|
Copper | Rubber plug |
Oil cooler connector |
location/I.D. mm | angle |
F |
– |
|
material | comment |
|
– |
Connector tolerance |
I.D. mm |
|
±0.09 |
Remarks: |
|
|
|
© Danfoss | DCS (CC) | 2017.02 |
|
|
DEHC.ED.200.A8.02 | 1 |