Datasheets
NF7MLX
MBP Compressor
R404A/R507, 220-240V 50Hz & 208-230V 60Hz
General
Code number 105F3721
Approvals EN 60335-2-34
Compressors on pallet 80
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -15 to 10 -23.3 to 7.2
Voltage range V 187 - 254 187 - 254
Max. condensing temperature continuous (short) °C 55 (60) 55 (60)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C – F2– – F2–
38°C – F
43°C – F
Remarks on application: 220V 50Hz nominal below -10°C evaporating temperature
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 21.0 –
Cut in Current, HST | LST A 21.0 –
Resistance, main | start winding (25°C) Ω 4.5 12.8
LBP MBP HBP LBP MBP HBP
– – F2–
2
– – F2–
2
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 10.5
Dimensions
Height mm A 203
Suction connector location/I.D. mm | angle C 8.2 | 15°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
320 (polyolester)
B 197
B1 –
B2 –
7.27
2310
© Danfoss | DCS (CC) | 2017.02
DEHC.ED.200.A8.02 | 1

ASHRAE MBP 230V, 60Hz, fan cooling F
Danf
already on order pro
All trademarks in this material are property of the respec
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 363 438 563 708
Power cons. in W 368 398 445 494
Current cons. in A 2.38 2.51 2.70 2.89
COP in W/W 0.99 1.10 1.27 1.43
815 874 1065 1284 1390
529 547 603 663 691
3.02 3.09 3.29 3.50 3.59
1.54 1.60 1.77 1.94 2.01
EN 12900 Household (CECOMAF) 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 413 489 618 768 879 940 1137 1362 1470
Power cons. in W 358 385 428 473 504 521 573 629 656
Current cons. in A 2.37 2.47 2.62 2.78 2.89 2.94 3.11 3.28 3.35
COP in W/W 1.15 1.27 1.45 1.62 1.74 1.80 1.98 2.16 2.24
ASHRAE MBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 466 585 673 722 880 1061 1148 1268
Power cons. in W 397 434 458 470 504 536 549 565
Current cons. in A 3.06 3.17 3.24 3.28 3.40 3.52 3.57 3.64
COP in W/W 1.17 1.35 1.47 1.54 1.75 3.52 2.09 2.24
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 511 635 726 777 940 1125 1215 1336
Power cons. in W 374 406 425 435 463 488 498 511
Current cons. in A 3.01 3.10 3.17 3.20 3.29 3.39 3.43 3.49
COP in W/W 1.37 1.57 1.71 1.78 2.03 2.31 2.44 2.62
Accessories for NF7MLX Figure Code number Test conditions
Starting relay 6.3 mm spade connectors
(protector incl.) Ambient temperature 32°C 35°C
a1
117U4139
Condensing temperature 43.3°C 54.4°C
EN 12900/CECOMAF
Protector 3/4 in. Texas Instruments MRP56EN-6 Suction gas temperature 32°C 35°C
Cover (UL approved) b 117U1021 Liquid temperature no subcooling 46.1°C
Start. capacitor 125 µF
6.3 mm spade connectors c 117U5018
Cord relief d 117U0349 Mounting accessories Code number
Cord relief for capacitor dc 117U0349 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.02 DEHC.ED.200.A8.02