Danfoss NF7FK Data sheet

NF7FK Standard Compressor R134a 115-127V 60Hz
General
Code number 105G5728
Approvals UL984
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 45
Voltage range V 95 - 135
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F S S
100°F S S
110°F F1F1–
Remarks on application: In capillary tube systems where non-equalized pressures may
occur at compressor start, or in areas with short power supply drop-outs, a starting
capacitor can be used for ensuring a successful start (CSIR).
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 29.4
Cut in Current, HST | LST A 29.4
Resistance, main | start winding (77°F) 2.0 9.1
Design
Displacement cu.in 0.44
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 23.0
Dimensions
Height inch A 8.00
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Cu-plated steel | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Cu-plated steel | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Cu-plated steel | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.76
B1
B2
S = Static cooling normally sufcient
O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.U4.22 / 502N1247 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 401 600 758 833 1112 1451 1604 1861 2355 2463 2946 3282
Power cons. in W 130 168 193 204 238 271 285 303 336 344 369 385
Current cons. in A 2.52 2.69 2.81 2.87 3.05 3.25 3.34 3.45 3.66 3.72 3.88 4.00
EER in BTU/Wh 3.08 3.57 3.93 4.09 4.68 5.35 5.63 6.13 7.01 7.17 7.99 8.52
ASHRAE MBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 357 533 674 740 988 1288 1194 1651 2089 2194 2611 2907
Power cons. in W 130 168 193 204 238 271 284 303 336 342 369 385
Current cons. in A 2.52 2.69 2.81 2.87 3.05 3.25 3.33 3.45 3.66 3.71 3.88 4.00
EER in BTU/Wh 2.74 3.18 3.49 3.64 4.16 4.76 5.05 5.44 6.22 6.41 7.08 7.55
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in W 95 142 180 198 264 344 380 441 557 583 696 775
Power cons. in W 130 168 193 204 238 271 285 303 336 344 369 385
Current cons. in A 2.52 2.69 2.81 2.87 3.05 3.25 3.34 3.45 3.66 3.72 3.88 4.00
COP in W/W 0.73 0.84 0.93 0.97 1.11 1.26 1.33 1.45 1.65 1.69 1.88 2.00
Accessories for NF7FK Figure Code number Test conditions
Starting relay 1/4 in. spade connect. a2 117U4131 Condensing temp.
Protector 3/4 in. Texas Instruments (pos.1) MRT30AEZ-6 Ambient temp.
Starting relay 1/4 in. spade connect. a2 117U4132 Suction gas temp.
Protector 3/4 in. Texas Instruments (pos.2) MRT30AEZ-6 Liquid temperature
ASHRAE
LBP
ASHRAE
MBP
130°F 130°F
90°F 95°F
90°F 95°F
90°F 115°F
EN 12900/
CECOMAF
131°F
90°F
90°F
131°F
Start. capacitor 320 µF 1/4 in. spade connect. c 117U5022
Cord relief for capacitor dc 117U0349 Mounting accessories Code number
Cord relief d 117U0349 Bolt joint for one comp. Ø: 5 /8 in. 118-1917
Cover b 117U1021 Bolt joint in quantities Ø: 5 /8 in. 118-1918
Snap-on in quantities Ø: 5/8 i n. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.U4.22 / 502N1247 Dec 2011
Loading...