NF6FK
Standard Compressor
R134a
115-127V 60Hz
General
Code number 105G5628
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -31 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 140 (158)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – S S –
100°F – – – S S –
110°F – – – F1F1–
Remarks on application: In capillary tube systems where non-equalized pressures may
occur at compressor start, or in areas with short power supply drop-outs, a starting
capacitor can be used for ensuring a successful start (CSIR).
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A – 29.4
Cut in Current, HST | LST A – 29.4
Resistance, main | start winding (77°F) Ω 2.0 9.1
Design
Displacement cu.in 0.37
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 23.0
Dimensions
Height inch A 7.72
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Cu-plated steel | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Cu-plated steel | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Cu-plated steel | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.52
B1 –
B2 –
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.T4.22 / 502N1246 1/2

ASHRAE LBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 286 462 602 668 912 1206 1344 1560 1982 2081 2484 2768
Power cons. in W 100 138 162 172 204 232 243 259 285 290 310 323
Current cons. in A 2.33 2.49 2.60 2.65 2.82 3.00 3.08 3.19 3.39 3.43 3.59 3.69
EER in BTU/Wh 2.87 3.35 3.71 3.87 4.48 5.19 5.53 6.01 6.95 7.17 8.00 8.57
ASHRAE MBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 254 411 535 593 811 1071 1194 1384 1758 1849 2202 2452
Power cons. in W 100 138 162 172 204 232 243 259 285 290 310 323
Current cons. in A 2.33 2.49 2.60 2.65 2.82 3.00 3.08 3.19 3.39 3.43 3.59 3.69
EER in BTU/Wh 2.55 2.98 3.30 3.44 3.98 4.61 4.91 5.34 6.16 6.38 7.09 7.59
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in W 67 109 143 158 216 286 317 369 468 490 586 653
Power cons. in W 100 138 162 172 204 232 244 259 285 291 310 323
Current cons. in A 2.33 2.49 2.60 2.65 2.82 3.00 3.08 3.19 3.39 3.44 3.59 3.69
COP in W/W 0.68 0.79 0.88 0.92 1.06 1.23 1.30 1.42 1.64 1.68 1.88 2.01
Accessories for NF6FK Figure Code number Test conditions
Starting relay 1/4 in. spade connect. a2 117U4131 Condensing temp.
Protector 3/4 in. Texas Instruments (pos.1) MRT30AEZ-6 Ambient temp.
Starting relay 1/4 in. spade connect. a2 117U4132 Suction gas temp.
Protector 3/4 in. Texas Instruments (pos.2) MRT30AEZ-6 Liquid temperature
ASHRAE
LBP
ASHRAE
MBP
130°F 130°F
90°F 95°F
90°F 95°F
90°F 115°F
EN 12900/
CECOMAF
131°F
90°F
90°F
131°F
Start. capacitor 320 µF 1/4 in. spade connect. c 117U5022
Cord relief for capacitor dc 117U0349 Mounting accessories Code number
Cord relief d 117U0349 Bolt joint for one comp. Ø: 5 /8 in. 118-1917
Cover b 117U1021 Bolt joint in quantities Ø: 5 /8 in. 118-1918
Snap-on in quantities Ø: 5/8 i n. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.T4.22 / 502N1246 Dec 2011