NF6.1FX.2
Standard Compressor
R134a
115-127V 60Hz
General
Code number 105G5631
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -31 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 140 (158)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – F1F1–
100°F – – – F1F1–
110°F – – – F1F1–
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 22.2 –
Cut in Current, HST | LST A 22.2 –
Resistance, main | start winding (77°F) Ω 2.0 3.1
Design
Displacement cu.in 0.37
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 22.0
Dimensions
Height inch A 7.76
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.52
B1 –
B2 –
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.402.R2.22 / 502N0283 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 309 493 647 721 999 1336 1488 1737 2208 2759 2818 3065
Power cons. in W 121 150 170 178 204 229 239 255 282 312 315 327
Current cons. in A 2.45 2.55 2.62 2.66 2.78 2.93 2.99 3.09 3.27 3.47 3.49 3.57
EER in BTU/Wh 2.56 3.28 3.82 4.06 4.91 5.83 6.22 6.81 7.82 8.85 8.95 9.36
ASHRAE MBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 275 438 575 641 888 1186 1321 1541 1959 2445 2498 2716
Power cons. in W 121 150 170 178 204 229 239 255 282 312 315 327
Current cons. in A 2.45 2.55 2.62 2.66 2.78 2.93 2.99 3.09 3.27 3.47 3.49 3.57
EER in BTU/Wh 2.28 2.91 3.39 3.61 4.36 5.18 5.52 6.04 6.94 7.84 7.93 8.29
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 73 116 153 170 236 316 352 411 522 652 666 724
Power cons. in W 120 150 169 178 204 230 240 256 283 313 316 329
Current cons. in A 2.45 2.55 2.62 2.66 2.79 2.93 3.00 3.10 3.28 3.48 3.50 3.58
COP in W/W 0.61 0.78 0.90 0.96 1.16 1.38 1.47 1.61 1.84 2.08 2.11 2.20
Accessories for NF6.1FX.2 Figure Code number Test conditions
Starting relay 1/4 in. spade connect.
Protector 3/4 in. Texas Instruments MRP36AEN Ambient temp.
a2
117U4127 Condensing temp.
Start. capacitor 280 µF 1/4 in. spade connect. c 117U5025 Suction gas temp.
Cover b 117U1021 Liquid temperature
ASHRAE
LBP
ASHRAE
MBP
130°F 130°F
90°F 95°F
90°F 95°F
90°F 115°F
EN 12900/
CECOMAF
131°F
90°F
90°F
no subcooling
Cord relief d 117U0349
Cord relief for capacitor dc 117U0349 Mounting accessories Code number
Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.402.R2.22 / 502N0283 Dec 2011