NF5.5FX Standard Compressor R134a 115-127V 60Hz
General
Code number 105G5623
Approvals UL984
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 45
Voltage range V 95 - 135
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F1F1–
100°F F1F1–
110°F F1F1–
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 22.2
Cut in Current, HST | LST A 22.2
Resistance, main | start winding (77°F) 2.0 3.1
Design
Displacement cu.in 0.37
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 17.5
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 22.0
Dimensions
Height inch A 7.76
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Cu-plated steel | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Cu-plated steel | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Cu-plated steel | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.52
B1
B2
S = Static cooling normally sufcient
O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.Q9.22 / 502N1255 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 298 481 627 695 950 1257 1397 1625 2065 2165 2588 2884
Power cons. in W 97.4 135 159 169 200 228 239 255 280 285 305 317
Current cons. in A 2.18 2.34 2.45 2.50 2.67 2.85 2.93 3.04 3.24 3.28 3.44 3.54
EER in BTU/Wh 3.06 3.57 3.95 4.12 4.76 5.51 5.85 6.38 7.37 7.60 8.49 9.09
ASHRAE MBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 265 428 558 618 845 1116 1247 1442 1831 1926 2293 2555
Power cons. in W 97.4 135 159 169 200 228 239 255 280 285 305 317
Current cons. in A 2.18 2.34 2.45 2.50 2.67 2.85 2.93 3.04 3.24 3.28 3.44 3.54
EER in BTU/Wh 2.72 3.17 3.51 3.66 4.23 4.90 5.22 5.66 6.54 6.76 7.52 8.05
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in W 70 114 148 165 225 297 330 384 488 511 611 680
Power cons. in W 97.4 135 159 169 200 228 239 255 280 286 305 317
Current cons. in A 2.18 2.34 2.45 2.50 2.67 2.85 2.93 3.04 3.24 3.29 3.44 3.54
COP in W/W 0.73 0.85 0.93 0.98 1.13 1.30 1.38 1.50 1.74 1.79 2.00 2.13
Accessories for NF5.5FX Figure Code number Test conditions
Starting relay 1/4 in. spade connect.
Protector 3/4 in. Texas Instruments MRP36AEN-6 Ambient temp.
a2
117U4127 Condensing temp.
Start. capacitor 280 µF 1/4 in. spade connect. c 117U5025 Suction gas temp.
Cover b 117U1021 Liquid temperature
ASHRAE
LBP
ASHRAE
MBP
130°F 130°F
90°F 95°F
90°F 95°F
90°F 115°F
EN 12900/
CECOMAF
131°F
90°F
90°F
131°F
Cord relief d 117U0349
Cord relief for capacitor dc 117U0349 Mounting accessories Code number
Bolt joint for one comp. Ø : 5 /8 in . 118-1917
Bolt joint in quantities Ø: 5 /8 in. 118-1918
Snap-on in quantities Ø: 5/8 i n. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.Q9.22 / 502N1255 Dec 2011