NF11FX.2
Standard Compressor
R134a
115-127V 60Hz
General
Code number 105G5916
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – 0 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 140 (158)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – – F2–
100°F – – – – F2–
110°F – – – – F2–
Remarks on application: Below 10°F only for 115V 60Hz nominal.
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 40.0 –
Cut in Current, HST | LST A 40.0 –
Resistance, main | start winding (77°F) Ω 1.0 2.9
Design
Displacement cu.in 0.68
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 22.0
Dimensions
Height inch A 8.00
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.76
B1 –
B2 –
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.402.V3.22 / 502N0661 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 1771 2351 2613 3042 3856 4805 4908 5335
Power cons. in W 360 412 433 465 521 581 588 614
Current cons. in A 5.42 5.71 5.83 6.03 6.39 6.79 6.83 7.00
EER in BTU/Wh 4.92 5.71 6.03 6.54 7.40 8.27 8.35 8.69
ASHRAE MBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 1573 2088 2320 2700 3421 4259 4350 4726
Power cons. in W 360 412 433 465 521 581 588 614
Current cons. in A 5.42 5.71 5.83 6.03 6.39 6.79 6.83 7.00
EER in BTU/Wh 4.37 5.07 5.36 5.80 6.57 7.33 7.40 7.70
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 419 556 618 720 912 1136 1160 1260
Power cons. in W 360 413 434 467 523 584 590 617
Current cons. in A 5.42 5.72 5.84 6.04 6.41 6.81 6.85 7.02
COP in W/W 1.16 1.35 1.42 1.54 1.74 1.94 1.96 2.04
Accessories for NF11FX.2 Figure Code number Test conditions
Starting relay 1/4 in. spade connect.
Protector 3/4 in. Texas Instruments MRT16ADK-6 Ambient temp.
a2
117U4151 Condensing temp.
Start. capacitor 410 µF 1/4 in. spade connect. c 117U5028 Suction gas temp.
Cover b 117U1021 Liquid temperature
ASHRAE
LBP
ASHRAE
MBP
130°F 130°F
90°F 95°F
90°F 95°F
90°F 115°F
EN 12900/
CECOMAF
131°F
90°F
90°F
no subcooling
Cord relief d 117U0349
Cord relief for capacitor dc 117U0349 Mounting accessories Code number
Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.402.V3.22 / 502N0661 Dec 2011