Danfoss NF11FX Data sheet

NF11FX Standard Compressor R134a 220V 50Hz
General
Code number 105G6944
Approvals
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -30 to 45
Voltage range V 198 - 242
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F2F2– F2F2–
100°F F
110°F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 20.0
Cut in Current, HST | LST A 20.0
Resistance, main | start winding (77°F) 4.5 12.8
Design
Displacement cu.in 0.68
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 23.0
Dimensions
Height inch A 8.00
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Cu-plated steel | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Cu-plated steel | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Cu-plated steel | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
B 7.76
B1
B2
F2F2–
S = Static cooling normally sufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.C4.22 / 520N1223 1/2
ASHRAE LBP 220V, 50Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 496 713 901 993 1336 1768 1950 2280 2907 3637 3730 4051
Power cons. in W 236 266 291 302 341 383 399 426 470 512 518 533
Current cons. in A 2.68 2.72 2.76 2.78 2.85 2.94 2.97 3.05 3.17 3.29 3.33 3.36
EER in BTU/Wh 2.10 2.68 3.10 3.29 3.92 4.62 4.89 5.35 6.18 7.10 7.20 7.60
ASHRAE MBP 220V, 50Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 442 636 803 885 1190 1575 1748 2029 2584 3230 3320 3595
Power cons. in W 236 266 291 302 341 383 399 426 470 512 518 533
Current cons. in A 2.68 2.72 2.76 2.78 2.85 2.94 2.97 3.05 3.17 3.29 3.33 3.36
EER in BTU/Wh 1.87 2.39 2.76 2.93 3.49 4.11 4.38 4.76 5.50 6.31 6.41 6.75
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 119 171 216 238 320 423 465 545 694 867 890 965
Power cons. in W 236 266 291 302 341 383 399 426 470 512 518 533
Current cons. in A 2.68 2.72 2.76 2.78 2.85 2.94 2.97 3.05 3.17 3.29 3.33 3.36
COP in W/W 0.50 0.64 0.74 0.79 0.94 1.10 1.17 1.28 1.48 1.69 1.72 1.81
Accessories for NF11FX Figure Code number Test conditions
Starting relay 1/4 in. spade connect.
Protector 3/4 in. Texas Instruments MRP56EN-6 Ambient temp. 90°F 95° 90°F
a2
117U4139 Condensing temp. 130°F 130° 131°F
ASHRAE
LBP
ASHRAE
MBP
EN 12900/
CECOMAF
Cover b 117U1023 Suction gas temp 90°F 95° 90°F
Start. capacitor 125 µF 1/4 in. spade connect. c 117U5018 Liquid temperature 90°F 115°F no subcooling
Cord relief d 117U0349
Cord relief capacitor dc 117U0349 Mounting accessories Code number
Bolt joint for one comp. Ø: 5/8 in. 118-1917
Bolt joint in quantities Ø: 5 /8 i n. 118-1918
Snap-on in quantities Ø : 5/ 8 in . 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.C4.22 / 520N1223 Dec 2011