NF10FX
Standard Compressor
R134a
220V 50/60Hz
General
Code number 105G6846
Approvals EN 60335-2-34, UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -30 to 45 -30 to 45
Voltage range V 198 - 242 198 - 242
Max. condensing temperature continuous (short) °F 140 (158) 140 (158)
Max. winding temperature continuous (short) °F 257 (275) 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F1F1– F2F2–
100°F F
110°F – – – – – –
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 20.0 –
Cut in Current, HST | LST A 20.0 –
Resistance, main | start winding (77°F) Ω 4.5 12.8
Design
Displacement cu.in 0.62
Oil quantity (type) .oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 16.1
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 23.0
Dimensions
Height inch A 8.00
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
B 7.76
B1 –
B2 –
– F2F2–
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.402.B2.22 / 520N0212 1/2
ASHRAE LBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 449 648 821 905 1222 1623 1804 2104 2693 3374 3454 3759
Power cons. in W 214 248 272 283 318 354 368 390 426 462 466 481
Current cons. in A 2.65 2.70 2.73 2.75 2.81 2.88 2.91 2.96 3.05 3.15 3.17 3.21
EER in BTU/Wh 2.09 2.61 3.02 3.20 3.85 4.60 4.92 5.42 6.34 7.33 7.44 7.86
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 108 156 197 217 293 389 432 503 643 804 823 895
Power cons. in W 214 248 272 283 318 354 368 390 426 462 466 481
Current cons. in A 2.65 2.70 2.73 2.75 2.81 2.88 2.91 2.96 3.05 3.15 3.17 3.21
COP in W/W 0.51 0.63 0.72 0.77 0.92 1.10 1.17 1.29 1.51 1.74 1.77 1.86
Accessories for NF10FX Figure Code number Test conditions
Starting relay 1/4 in. spade connect.
Protector 3/4 in. Texas Instruments MRP56EN-6 Ambient temp. 90°F 90°F
a2
117U4139 Condensing temp. 130°F 131°F
ASHRAE LBP
EN 12900/CECOMAF
Cover b 117U1023 Suction gas temp 90°F 90°F
Start. capacitor 125 µF 1/4 in. spade connect. c 117U5018 Liquid temperature 90°F no subcooling
Cord relief d 117U0349
Cord relief capacitor dc 117U0349 Mounting accessories Code number
Bolt joint for one comp. Ø: 5 /8 i n. 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.402.B2.22 / 520N0212 Dec 2011