Fact Sheet
NEMA 3R Rated VLT® AQUA Drive
The VLT® AQUA Drive withstands outdoor
environments. A NEMA/UL Type 3R rated enclosure,
and standard 1,000-foot motor cable runs, provide
maximum mounting exibility.
Power range:
1-phase, 200–240 VAC: 1.5–30 HP
1-phase, 380–480 VAC: 10–50 HP
3-phase, 200–240 VAC: 1/3–60 HP
3-phase, 380–480 VAC: 1/2–450 HP
3-phase, 525–690 VAC: 15–400 HP
Suitable for installations that require
protection against rain or splashing water,
NEMA/UL Type 3R rated variable frequency
drives can be installed directly at the
equipment location without an additional
protective enclosure. The variable frequency
drive is built with all cast aluminum parts so
that the enclosure will not rust.
Feature Benet
SmartStart programming Quick and easy start-up
All cast aluminium parts No need for separate cover or enclosure*
Conformal coated circuit board option Additional protection in corrosive environments
Info key opens on board manual No manual needed to operate
Initial Ramp Performance that matches pump demands
Fan designed to withstand moisture and rain Reliable operation
Flow compensation Improved setpoint control
End of pump curve detection Protects pump, detects leakag
No/low flow detection Pump protection
Pipe fill mode Eliminates water hammer
Can be installed near the motor or blower Facilitates modular plant design
1000’ motor cable runs (unshielded) Short motor cables reduce EMI/RFI
Phase Conversion
For remote areas such as lift stations or
farming fields where 3-phase power is not
available, single-phase drives offer phase
conversion and speed control in a single,
compact package. Phase-converting VLT®
AQUA Drives enable the use of cost-effective
three-phase motors with only single-phase,
240 VAC or 480 VAC service.
Perfect
tool for: lift stations,
pump stations, golf
courses, irrigation,
and other outdoor
applications
Reliable Maximum uptime
Robust, single enclosure Reduced cost and maintenance
Unique cooling concept with no ambient air flow
through electronics housing
Max. ambient temp. 50° C without derating No external cooling or oversizing necessary
User friendly Simplied operation and lower costs
Award-winning LCP keypad design
Easy installation Lower startup costs
Watertight USB plug can be mounted in the bottom
of the drive
* For outdoor installations: The drive must be installed under a suitable cover with weather shield to protect from direct
exposure to sun, snow and ice.
Reliable operation in harsh environments
Reduced space requirements and commissioning
time
Drive enclosure can remain closed while making
setup or programming changes
drives.danfoss.com
Outdoor weather shield
Mount above FC 202 to protect from direct
sun and falling debris.
Stainless steel back plate
For panel or wall mounting, a stainless steel
back plate is available to direct air from the
fan through the rear heatsink.
Mains supply (L1, L2, L3)
Supply voltage 200–240 V ±10%, 380–480 V ±10%, 525–690 V ±10%
Supply frequency 50/60 Hz
Displacement Power Factor (cos φ) near unity (> 0.98)
Switching on input supply L1, L2, L3 1–2 times/min.
Output data (U, V, W)
Output voltage 0-100% of supply
Switching on output Unlimited
Ramp times 1–3600 sec.
Closed loop 0–132 Hz
Digital inputs/outputs
Programmable digital inputs (standard) 6 (two can be used as digital outputs)
Logic PNP or NPN
Voltage level 0–24 VDC
Analog inputs
Analog inputs (standard) 2
Modes Voltage or current
Voltage level 0 to +10 V (scaleable)
Current level 0/4 to 20 mA (scaleable)
Pulse inputs
Programmable pulse inputs (standard) 2 (two of the digital inputs can be used as pulse
inputs)
Voltage level 0–24V DC (PNP positive logic)
Pulse input accuracy (0.1–110 kHz)
Analog outputs
Programmable analog outputs (standard) 1
Current range at analog output 0/4-20 mA
Relay outputs
Programmable relay outputs (standard) 2 (240 VAC, 2 A and 400 VAC, 2 A)
External DC supply
External 24V DC supply card (option) Provides backup power for control and option cards
Fieldbus communication
FC Protocol and Modbus RTU built in. DeviceNet, Profibus Profinet, Ethernet IP, & Modbus TCP modules
optional
Ambient temperature
Minimum 32° F (0° C), Maximum 122° F (50° C)
Watertight USB plug
A USB plug can be mounted in the bottom of
the enclosure, allowing the drive to stay
closed while making setup or programming
changes using MCT 10 setup software.
Tel. +1 (888) DANFOSS | www.danfossdrives.com | E-mail: salesinformation@danfoss.com
Danfoss Drives: Houston, TX • Loves Park, IL • Milwaukee, WI • Raleigh, NC • Stoney Creek, ON
USDD.PFM.200.A3.22 © Copyright Danfoss Drives | 2019.01
PC software tools
MCT 10: ideal for starting up and
servicing the drive
MCT 31: harmonics calculations tool