NEMA 3R Rated VLT® AQUA Drive

The VLT® AQUA Drive withstands outdoor environments. A NEMA/UL Type 3R rated enclosure, and standard 1,000-foot motor cable runs, provide maximum mounting flexibility.

Power range:

1-phase, 200–240 VAC: 1.5–30 HP1-phase, 380–480 VAC: 10–50 HP3-phase, 200–240 VAC: 1/3–60 HP3-phase, 380–480 VAC: 1/2–450 HP3-phase, 525–690 VAC: 15–400 HP

Perfect

tool for: lift stations, pump stations, golf courses, irrigation, and other outdoor applications

Suitable for installations that require protection against rain or splashing water, NEMA/UL Type 3R rated variable frequency drives can be installed directly at the equipment location without an additional protective enclosure. The variable frequency drive is built with all cast aluminum parts so that the enclosure will not rust.

Feature

SmartStart programming

All cast aluminium parts

Conformal coated circuit board option

Info key opens on board manual

Initial Ramp

Fan designed to withstand moisture and rain

Flow compensation

End of pump curve detection

No/low flow detection

Pipe fill mode

Can be installed near the motor or blower

1000’ motor cable runs (unshielded)

Reliable

Robust, single enclosure

Unique cooling concept with no ambient air flow through electronics housing

Phase Conversion

For remote areas such as lift stations or farming fields where 3-phase power is not available, single-phase drives offer phase conversion and speed control in a single, compact package. Phase-converting VLT® AQUA Drives enable the use of cost-effective three-phase motors with only single-phase, 240 VAC or 480 VAC service.

Benefit

Quick and easy start-up

No need for separate cover or enclosure* Additional protection in corrosive environments No manual needed to operate

Performance that matches pump demands Reliable operation

Improved setpoint control

Protects pump, detects leakag

Pump protection

Eliminates water hammer

Facilitates modular plant design

Short motor cables reduce EMI/RFI

Maximum uptime

Reduced cost and maintenance

Reliable operation in harsh environments

Max. ambient temp. 50° C without derating

User friendly

Award-winning LCP keypad design

Easy installation

Watertight USB plug can be mounted in the bottom of the drive

No external cooling or oversizing necessary

Simplified operation and lower costs

Reduced space requirements and commissioning time

Lower startup costs

Drive enclosure can remain closed while making setup or programming changes

* For outdoor installations: The drive must be installed under­ a suitable cover with weather shield to protect­ from direct exposure to sun, snow and ice.