Danfoss LX Cable Data sheet

Data Sheet LX Cable for Electric Floor Heating Applications
General Information
Technical Data
The Danfoss LX Electric Floor Heating Cable Systems combine the highest comfort levels with maximum energy eciency. It’s a proven technology that’s safe, reliable and energy ecient.
• Single point connection
• Twin conductor cable
• Eliminates EMF’s (Electromagnetic elds)
• Safety approved for wet locations
• The only cable to pass the rigorous IEEE impact test
• Flexible installation
• Durable construction
• Genuine twenty year non-prorated warranty
Typical Application: Plywood Suboor, Concrete Suboor, Engineered Wood, Laminate,
Tile Floor, Stone Floor Cable Construction: Twin conductor Rated Voltage: 120V, 240V Output: 3W/ft. (10W/m) Heating Element Size: 40 ft. (12.2m) to 630 ft. (192m) Cold Lead: 10 ft. (3.0 m) Bending Radius: Minimum 3/4 inch (19 mm) Cable Diameter: 3/16 inch (4.8 mm) Conductor Insulation: TeonTM FEP Outer Insulation: PVC Max. Temperature: 212°F (100°C) Min. Installation Temp: 50°F (10°C)
See power lead label for NEC connection color code.
Ordering Information LX Cables - 120V
Cable strapping is supplied with product. Additional cable strapping can be ordered separately
2” centers provide 18/W sq.ft.
3” centers provide 12/W sq.ft.
4” centers provide 9/W sq.ft.
Watt output of the 240V cable is reduced by 25% when oper­ated at 208V (approximately 2W/ft.)
Power leads are 10 feet in length
Floor sensor conduit is not included (part #19809099)
Contactor or Power Module is required for loads exceeding 15 amps on a single thermostat
© Copyright 2018 Danfoss NA.EFH.LXCD.04/18 TEL: 1-888-326-3677 FAX: 416-352-5981 1
Part No.
088L3140 40 5 10 15 1.0 120 120.0 15 (4.6)
088L3141 60 10 15 20 1.5 180 80.0 15 (4.6)
088L3142 80 15 20 25 2.0 240 60.0 30 (9.1)
088L3143 120 20 30 40 3.0 360 40.0 30 (9.1)
088L3144 160 25 40 55 4.0 480 30.0 75 (22.9)
088L3145 200 35 50 65 5.0 600 24.0 75 (22.9)
088L3146 240 40 60 80 6.3 755 19.2 75 (22.9)
088L3147 280 45 70 95 7.2 865 16.7 75 (22.9)
088L3148 315 50 80 105 8.0 960 15.0 75 (22.9)
Length
(feet)
Approximate Heat Coverage
2” spacing
Standard
3” spacing
4” spac-
ing
Amps
Watts
(3W/ft.)
Ohms
LX Strapping
Included:
feet (m)
Ordering Information LX Cables - 240V
Cable strapping is supplied with product. Additional cable strapping can be ordered separately
2” centers provide 18/W sq.ft.
3” centers provide 12/W sq.ft.
4” centers provide 9/W sq.ft.
Watt output of the 240V cable is reduced by 25% when oper­ated at 208V (approximately 2W/ft.)
Power leads are 10 feet in length
Floor sensor conduit is not included (part #19809099)
Contactor or Power Module is required for loads exceeding 15 amps on a single thermostat
Part No.
088L3080 80 15 20 25 1.0 240 235.1 30 (9.1)
088L3081 120 20 30 40 1.5 360 157.8 30 (9.1)
088L3082 160 25 40 55 2.0 480 120.0 75 (22.9)
088L3083 200 35 50 65 2.5 600 95.2 75 (22.9)
088L3084 240 40 60 80 3.0 720 79.5 75 (22.9)
088L3085 280 45 70 95 3.5 840 68.6 75 (22.9)
088L3086 320 55 80 105 4.0 960 59.7 75 (22.9)
088L3087 360 60 90 120 4.5 1,080 53.3 105 (32.0)
088L3088 400 65 100 135 5.0 1,200 48.0 105 (32.0)
088L3089 440 75 110 145 5.5 1,320 43.3 150 (45.7)
088L3090 480 80 120 160 6.0 1,440 39.9 150 (45.7)
088L3091 570 95 140 190 7.1 1,705 33.7 150 (45.7)
088L3092 630 105 160 210 8.0 1,920 30.1 150 (45.7)
Length
(feet)
Approximate Heat Coverage
2” spacing
Standard
3” spacing
4” spacing
Amps
Watts
(3W/
ft.)
Ohms
LX Strapping
Included: feet
(m)
Thermostats
Accessories
Warranty
Technical Services
Danfoss can accept no responsibility for possible errors in catalogs, brochures, other printed materials, and website information. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alteration can be made without subsequent changes being necessary in
specications already agreed upon. All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Part No. Description
088L5140 LX205T WIFI Touch Screen Thermostat (Programmable)
088L5136
088L5130 LX Thermostat with Floor & Air Sensor (Programmable) 088L5137 LX205 Thermostat (Non-Programmable)
Note: All thermostats include a oor sensor with a 10 foot lead.
Part No. Description 088L0014 LX Repair Kit (includes crimp connectors, repair wire, heat shrink tubes) 088L0028 Little Buzzer - Continuity Alarm 088L0076 Reect Insulation Plates (Box of 10 plates, approx. 50 sq.ft.) 088L0077 Reect Insulation Plates (Box of 4 plates, approx. 20 sq.ft.) 088L1053 Cable Strapping (15ft./4.5m) 088L1054 Cable Strapping (75ft./22.9m)
088L3008
ETF-110/99C Replacement Thin Floor Sensor (10K Ω) for Thermostat
19809099 Sensor Conduit (8 feet)
Genuine twenty year comprehensive extended warranty against defects in material, design, and workmanship.
For technical questions, please contact Danfoss Heating Division North America at 1-888-326-3677. More information on Danfoss Electric Heating products is available at www.LX.Danfoss.com.
Danfoss
Tel: 1-888-DANFOSS (326-3677) option #3 Fax: 416-352-5981
www.LX.Danfoss.com
LX205T Touch Thermostat (Programmable)
Replacement oor sensor for LX Thermostat Models 008L5130, 088L5132, 088L5133 only
Danfoss LX
BRINGING WARMTH TO LIFE
© Copyright 2018 Danfoss NA.EFH.LXCD.04/18 TEL: 1-888-326-3677 FAX: 416-352-5981 2
Loading...