Danfoss LX 420, LX 421 User Manual

USER MANUAL
LX 420, 421
Table of contents
English ...................................................... 2 Français .................................................... 5
088L3353 - 01.01 57470
Product program
This user manual covers following thermo­stats with built-in GFCI LXstat-420 Incl. fl oor sensor 3m LXstat-421 With built-in room
Introduction The thermostat is an electronic on/off ther­mostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat. The thermo­stat has integrated a Ground Fault Circuit Interrupter (GFCI, Class A). The thermostat and the GFCI is a dual model suitable for 120/240 V 50/60 Hz supply.
The thermostat type LXstat-420 has an external temperature sensor that is normally placed in the fl oor construction. In this con­fi guration the thermostat controls the temperature of the fl oor and not the temperature within the room. The thermostat type LXstat-421 has a built-in temperature sensor. In this confi guration the thermostat controls the temperature of the room.
The thermostat has two adjustable set points, one for the day operation and one for the night setback temperature. Switching
sensor
1. Getting started
Buttons
between the two set points is easily done with one push at the OK (
The temperature can be displayed in eigher °C or in °F. Switching can be done on the pin button marked with (
The thermostat has a pin button marked R, allowing you to reset the thermostat to fac­tory settings. These are listed at the end of this manual with space for you to record your settings.
) button.
)
A
B
C
D
E
I
H
A: Reset of GFCI B: Red light indicating ground fault
G
C: Test of GFCI
D: Pin button ºC / ºF E: Display F: Reset to factory setting G: Adjustment down H: OK - accept I: Adjustment up
2
Display symbols
J
J: Clock function
Wake
Night
K: Heating on
K
Setting the thermostat into operation
Actual temperature setting is shown in the display and the thermostat is ready for use.
Comfort mode
To jump between the two set points press the OK (
Night, Setback temperature
OFF
To change the temperature press UP ( ) or
) to increase or decrease the tempera-
DOWN ( ture. The display will fl ash for 5 seconds, and will then show the new temperature setpoint.
) button
To change the temperature press UP ( ) or DOWN (
) to increase or decrease the tempera­ture. The display will fl ash for 5 seconds, and will then show the new temperature setpoint.
To turn the thermostat OFF, press DOWN ( ) until OFF appears in the display.
DO NOT USE THE TEST BUTTON ON THE GFCI TO SWITCH OFF THE HEATING INSTALLATION. The GFCI will automatically be reset after a dis­connection of the mains supply