Danfoss living eco Data sheet

Data Sheet
living eco®, Electronic Radiator Thermostat
Application
Ordering
Features:
• Energy savings
• Easy to install
• Easy to operate - only three buttons
• Provides high comfort
• Open window function
• Valve exercise function
• PID control (precise control)
• Adaptive learning
• Weekly programs with adjustable temperature
living eco® is a stand-alone intelligent electronic and programmable radiator thermostat for residential use.
living eco® is easy to install and is supplied with adapters for all thermostatic valves manufac­tured by Danfoss and most other radiator valve manufacturers.
living eco® is battery powered, compact and very easy to operate with only three buttons.
Adapters (included) Instruction - languages Code no.
set-backs
• Battery lifetime 2 years
• Min./max. temp. limitation
• Child lock
• Holiday/away function
• Frost protection
• Backlit display
• Variable set points and up to 3 set-back periods per day
Accessories
Danfoss RA UK/DE/DK/NL/FR/PL/SE/FI 014G0050
Danfoss RA / K UK/DE/DK/NL/FR/PL/SE/FI 014G0051
Danfoss RA / K UK/CZ/RU/TR/HU/HR/SI/IT 014G0052
Danfoss RA / K UK/DE/DK/NL/FR/PL/SE/FI 014G0064
Danfoss RAV and RAV/RAVL/K UK/DK/DE/FR 014G0070
Typ e Code no.
Adapters for RAV & RAVL valves 014G0250
Adapter for RA valves 014G0251
Adapter for K valves 014G0252
Adapter for RTD valves 014G0253
Adapter for M28 MMA valves 014G0255
Adapter for M28 Herz valves 014G0256
Adapter for M28 Orkli valves 014G0257
Adapter for M28 COMAP valves 014G0258
VDFNT402 © Danfoss 02/2014
1
Data Sheet living eco®, Electronic Radiator Thermostat
Intertek
Specications
Thermostat type Programmable electronic radiator valve controller
Recommended use Residential (pollution degree 2)
Actuator Electromechanical
Display Grey digital with backlight
Software classication A
Control PID
Power supply 2 x 1.5 V alkaline AA batteries
Power consumption
3 μW in standby
1.2 W when active
Battery life 2 years
Low batteri signal
Battery icon will ash in display. If battery level is critical, the whole display will ash.
Ambient temperature range 0 to 40 °C
Transportation temperature range -20 to 65 °C
Maximum water temperature 90 °C
Temperature setting range 4 to 28 °C
Measurement interval Measures temperature every minute
Pre-installed Programmes
Clock accuracy +/- 10 min/year
Spindle movement Linear, up to 4.5 mm, max. 2 mm on valve (1 mm/s)
Noise level <30 dBA
Safety classication Type 1
Open-window function
Activated at temperature decrease of approx. 0.5 °C over 3 minutes
Weight (incl. batteries) 177 g (with RA adapter)
IP class
20 (not to be used in hazardous installations or in places where it will be exposed to water)
Approvals, markings etc.
Programme without automatic temperature reduction.
P0
This programme maintains the temperature constant all day and night.
Saving programme which as default lowers the temperature to 17 °C at night (22:30 - 06:00 hrs).
P1
Time and temperature are congurable.
Extended saving programme which as default lowers the temperature to 17 °Cat night (22:30 - 06:00 hrs), and during the day on weekdays (08:00 - 16:00 hrs).
P2
Time and temperature are congurable.
Travel programme which lowers the temperature when you are away. Time and temperature are congurable.
Frost protection programme. The thermostat will maintain a constant temperature of 4-10 °C in the room, ensuring frost protection.
2
VDFNT402 © Danfoss 02/2014
Data Sheet living eco®, Electronic Radiator Thermostat
RA
K
Measuring the room temperature
Main features
living eco® is measuring the temperature with two built-in sensors - one behind the display and one near the valve. Based on both readings the room temperature is calculated for an area approx. 20 cm in front of the display. This allows living eco® to control the actual room temperature very accurately.
Be aware that sources of cold or heat, e.g. fire­place, direct sun or draft, might affect the func­tion of living eco®.
Open-window function
living eco® features an Open-window function, which closes the valve if the room temperature is falling dramatically, thus reducing the heat loss. The heat is turned o for up to 30 minutes, before living eco® returns to its original settings. When Open-window has been activated, the function is quarantined for 45 minutes.
Adjusting to the valve
During the first night of operation living eco® will shut off the radiator heat and then open again to detect the exact opening point of the valve. This will allow living eco® to control the heat as efficiently as possible. If necessary, the procedure is repeated once a night for up to a week. You might experience the valve being warm during the adjustment procedure, regardless of the room temperature.
Child lock
Activating the child lock feature will protect the settings from tampering.
20 cm
Note! The displayed temperature is always the set temperature, not the actual room temperature.
Intelligent Control (Forecast)
During the first week of operation living eco® learns when it is necessary to start heating the room in order to reach the correct temperature at the correct time. The intelligent control will continuously adjust the heating time compared to seasonal tempera­ture changes.
Automatic valve exercising
To keep the radiator valve functional and at its best, living eco® automatically exercises the valve every Thursday at approx. 11:00 hrs by opening it fully and then return to normal setting.
Daylight saving time
As default living eco® will automatically shift between daylight saving time and normal time. If necessary, the daylight saving time function can be disabled.
Installation
M must be ashing on the display before installation.
1. Start by mounting the appropriate adapter.
2. Tighten RA adapter using the 2 mm Allen key. Hand-tighten K adapter (max. 5 Nm).
3. Screw the thermostat onto the adapter and tighten by hand (max. 5 Nm).
4. Activate Installation Mode to x living eco® correctly onto the valve: Press for 3 seconds to select the Function Menu, then use to select M. When M ashes, press .
VDFNT402 © Danfoss 02/2014
3
Data Sheet living eco®, Electronic Radiator Thermostat
91 mm
Ø51 mm
83 mm
Ø51 mm
78 mm
Ø51 mm
Dimensions
with RA valve adapter with RAV/RAVL valve adapter
with K valve adapter
Danfoss A/S
Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone: +45 7488 8000 Fax: +45 7488 8100 Email: heating.solutions@danfoss.com www.heating.danfoss.com
4
VDFNT402 © Danfoss 02/2014