living connect®, Z-Wave Certified Electronic Radiator Thermostat
Application
This documents provides information about the
Z-Wave commands supported by living connect®
and guidelines on the implementation of Z-Wave
controllers as well as general description of the
living connect® and how to mount it on a radiator.
living connect®is a electronic radiator thermostat.
It can be controlled by either a Danfoss LinkTM CC
(Central Controller) or a Z-Wave certified controller.
(For control by Danfos LinkTM CC see separate data sheet)
living connect® uses Z-Wave wireless communication technology, is easy to install and is supplied
with adapters for all thermostatic valves manufactured by Danfoss and most other radiator
valve manufacturers.
living connect® is battery powered, compact and
very easy to operate with only three buttons on
the front.
The temperature can be changed at any time using the buttons on living connect®. The change is
transmitted directly to the controller, which can
synchronize the other electronic radiator thermostats in the same room. living connect® features
an open-window function, which closes the valve
if the temperature in the room is falling dramatically. Main features in a system with the controller:
Energy saving
▪
Easy to install
▪
Easy to operate - only three buttons
▪
Provides high comfort
▪
Open window function
▪
Valve exercise function
▪
PID control
▪
Weekly programs with variable set points for
▪
each day
Battery lifetime 2 years, if properly suppor-
Data Sheetliving connect®, Z-Wave Certified Electronic Radiator Thermostat
Code numbers
Accessories
Specification
Code no.Adapter (included)Language instructions
014G0001Danfoss RA
014G0002Danfoss RA and M30 x 1.5 (K)
TypeCode no.
RAV & RAVL adaptor014G0250
RA adaptor014G0251
M30 x 1.5 (K) adaptor014G0252
RTD adaptor014G0253
Control system/inputStandard Z-Wave control units
Transmission frequencyWireless Z-Wave/868.42 MHz
Transmission rangeUp to 30 meters
SynchronizingConfigurable (5 min. recommended)
Screen/displayGrey digital with backlit
Actuator typeElectromechanical
Software classificationA
ControlPID
Power supply2x1.5V AA alkaline, class III (SELV)
Battery life2 years
Low battery signal
Ambient temperature0 to 40⁰C
Transportation temperature range-20 to 65⁰C
Temperature setting range4 to 28⁰C
Recommended useResidential
Open-window functionYes
SizeRA: L: 91 mm Ø:51 mm/K: L78 mm Ø: 51 mm
Noise level< 30 dBA
Weight incl. battery177 g
Safety classificationType 1
Mechanical strength70 N (max. force from valve)
Maximum water temperature90°C
Movement typeLinear
Spindle movement2-3 mm on valve
Maximum extension4.5 mm
Temperature samplingMeasures temperature every minute
Speed of adjustment1 mm/s
Power consumption3 mW in standby, 1.2 W when active
Ball pressure test75°C
IP class*20
Battery icon and alarm bell will flash in display. If the battery
level is critical, the whole display will flash.
UK/DE/DK/NL
FR/PL/SE/FI
UK/DE/DK/NL
FR/PL/SE/FI
* This thermostat should not be used in hazardous installations or in places where it will be exposed
to water.
Data Sheetliving connect®, Z-Wave Certified Electronic Radiator Thermostat
Marking
Installation
living connect® is supplied with adapters for
Danfoss RA valves and valves with M30X1.5
(K) connections (code no. 014G0002), two alkaline AA batteries and a 2 mm Allen key.
Inserting the batteries
Remove the battery cover and insert the two
batteries. Ensure that the batteries are correctly inserted. A capital "M" must flash on the
display before installation.
Data Sheetliving connect®, Z-Wave Certified Electronic Radiator Thermostat
Connecting living connect®
to a Z-Wave controller
In Z-Wave connecting a device is called “Inclusion” or “Learn mode”.
To connect living connect® to a Z-Wave controller then:
Ensure living connect® is factory reset as explained in the user manual.
▪
Activate "Inclusion" on the Z-Wave controller.
▪
Quickly press and release the select button on living connect®.
▪
Observe both controller and living connect® for status of the process.
▪
Technical requirements:
After a succesful "Inclusion" the controller must send a WAKE_UP_INTERVAL_SET command to
▪
living connect® in order to specify where and when living connect® should communicate wirelessly.
After sending the WAKE_UP_INTERVAL_SET command, the controller must assign return routes,
▪
so living connect® can reach its destination i.e. the nodeID set in the WAKE_UP_INTERVAL_SET
command.
living connect® will not commence its periodic communications if it is in "Installation mode". "In-
▪
stallation mode" is for physical installation and should not be confused with "Inclusion". Please
consult the user manual of living connect® for instructions on how to leave "Installation mode".
A Z-Wave controller will have access to all living connect® features, which are exposed using
▪
standard Z-Wave command classes.
See other section of this document for more information.
Disconnecting living connect® from a Z-Wave con-
troller
Activate special awake
mode on living connect®
In Z-Wave disconnecting a device is called “Exclusion”.
To disconnect living connect® from a Z-Wave controller then:
Activate "Exclusion" on the Z-Wave controller.
▪
Quickly press and release the select button on living connect®.
▪
Observe both controller and living connect® for status of the process.
▪
living connect® will turn on radio communication for short periods of time at specific intervals in order to communicate with its controller, unless such a controller has yet to be configured. When radio
communication is not needed by living connect® it will turn the radio off to conserve battery life.
If a user needs to configure a controller for living connect® or send more information to living con-
nect® then the user can activate a special 5 seconds awake mode by pressing the select button on
living connect®.
Data Sheetliving connect®, Z-Wave Certified Electronic Radiator Thermostat
Important
living connect® and ZWave repeaters
Implemented Z-Wave device classes
The nodeID set in the WAKE_UP_INTERVAL_SET command must be for a permanently listening
▪
device which reponds to the commands sent from living connect®. This means PC's with USB
sticks will only work if the PC is never turned off. If the controller is turned off for extended periodes, living connect® will use the batteries too fast.
To preserve battery - Wake_Up_intervals should not be set to less than 5 min. Increasing the
▪
time between intervals will increase battery life but can reduce user satisfaction due to long reaction times.
Although living connect® supports single commands, multi commands must always be used to
▪
ensure two years battery lifetime.
If multiple thermostats are installed in the same room it is important that the controller ensures
▪
that they all have the same schedule and the same setpoint.
In order to ensure proper routing with battery operated devices, the controller must support
▪
SUC.
living connect® may benefit if more mains powered Z-Wave devices are added to a Z-Wave network.
Mains powered Z-Wave devices improve the reliability of a Z-Wave network as they can act as repeaters and thus provide alternate routes for communication.
Z-Wave Device ClassesDevice Class Implemented
Generic DeviceGENERIC_TYPE_THERMOSTAT
Specific DeviceSPECIFIC_TYPE_SETPOINT_THERMOSTAT
Supported and controlled
Z-Wave command classes
Z-Wave Command Classes SupportedDescription
COMMAND_CLASS_BATTERYGet current battery status of living connect®.
COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULEControl a temperature offset to the ther-
mostat setpoint of living connect®. The temperature offset is defined by schedules and
schedule overrides.
COMMAND_CLASS_CLOCKSet or get the current living connect® clock.
COMMAND_CLASS_MANUFACTURER_PROPRIETARYSpecial command used for communication
with a Danfoss Link system.
COMMAND_CLASS_MANUFACTURER_SPECIFICGet manufacturer ID of system.
COMMAND_CLASS_MULTI_CMDA special Z-Wave command used by living
connect® to encapsulate multiple commands in one command and thereby conserve battery life.
COMMAND_CLASS_PROTECTIONSet or get living connect® local protection
mode.Possible local protection values are:
0 = no protection
2 = fully locked (tamperproof)
COMMAND_CLASS_THERMOSTAT_SETPOINTSet or get current thermostat setpoint of
living connect®.Heating setpoint is the only
supported setpoint type.
COMMAND_CLASS_VERSIONGet version of product and command
classes.
COMMAND_CLASS_WAKE_UPA special Z-Wave command used by living
connect® to synchronize communication
with its controller.