Data Sheet
Danfoss Link™ MPB with Danfoss Link™ SCM or with Danfoss Link™ HC
Applications |
The Danfoss Link™ SCM (Simple Communication |
|
Module) is an electronic controller for turning the |
|
AWAY function ON/OFF in a Danfoss Link™ sys- |
|
tem. |
Smartphone app
For Android phones and iPhones you can download the Danfoss Link™ ButlerApp for easy communication with the Danfoss Link™ MPB.
The Danfoss Link™ MPB (Mobile Phone Butler) |
|
|
Make sure the right |
|
can be connected to the Danfoss Link™ SCM in |
N |
|||
Danfoss Link™ CC soft- |
||||
order to remotely control the Danfoss Link™ SCM |
|
|||
|
ware version is ap- |
|||
via text messaging. Other ON/OFF devices; sen- |
|
|||
|
plied. Correct version: |
|||
sors, manual switches, etc. can also be connected |
|
|||
|
2.5.57 or higher. |
|||
to the Danfoss Link™ SCM. |
|
|
||
|
|
|
||
The AWAY Function sets a fixed temperature for |
|
|
||
all rooms. The AWAY temperature can only be set |
|
|
||
on the Danfoss Link™ CC (Central Controller), de- |
|
|
||
fault setting is 15 °C. |
|
|
System
Fig. 1: Danfoss Link™ MPB with Danfoss Link™ SCM
Fig. 2: Danfoss Link™ MPB with Danfoss Link™ HC
Danfoss Heating Solutions |
VDFZG102 |
© Danfoss |
12/2012 |
1 |
Data Sheet |
Danfoss Link™ MPB with Danfoss Link™ SCM or with Danfoss Link™ HC |
|
|
Ordering |
Product |
|
Code no. |
|
Danfoss Link™ HC (Hydronic Controller) |
|
014G0100 |
|
|
|
|
|
Danfoss Link™ MPB (Mobile Phone Butler) |
|
014G0102 |
|
|
|
|
|
Danfoss Link™ SCM (Simple Communication Module) |
014G0105 |
|
Technical Specifications |
|
|
|
|
|
|
|
Type |
Specifications |
|
|
for Danfoss LinkTM SCM |
Operating voltage |
8-32 V DC |
|
|
Operation voltage (net adapter) |
220-240 V~, 50 Hz |
|
|
|
|
|
|
Standby consumption |
0.9 W |
|
|
|
|
|
|
Ambient temperature |
0 °C to +45 °C |
|
|
|
|
|
|
Transport temperature |
-10 °C to +60 °C |
|
|
|
|
|
|
Transmission frequency |
868.42 MHz |
|
|
|
|
|
|
Transmission range in normal buildings |
Up to 30 m |
|
|
|
|
|
|
Transmission power |
Max. 1 mW |
|
|
|
|
|
|
Pollution degree |
2 |
|
|
|
|
|
|
Ball pressure test temperature |
75 °C |
|
|
|
|
|
|
Software classification |
Class A |
|
|
|
|
|
|
IP class |
20 |
|
|
|
|
|
|
Dimensions |
80 x 80 x 30 mm |
|
Technical specifications |
|
|
|
|
|
|
|
Type |
Specifications |
|
|
for Danfoss Link™ MPB |
Operating voltage |
12 V DC |
|
|
|
|
|
|
Operation voltage (net adapter) |
90 - 264 V AC |
|
|
|
|
|
|
Standby consumption |
Max. 0.5 W |
|
|
|
|
|
|
Contact load capacity (max) |
0.5 A - 250 V AC |
|
|
|
1 A - 30 V DC |
|
|
|
|
|
|
Ambient temperature |
-5 to +55 °C when humidity is < 95% |
|
|
|
|
|
|
Transport temperature |
-30 to +70 °C when humidity is < 90% |
|
|
|
|
|
|
Transmission frequency |
900 MHz, 1800 MHz |
|
|
|
|
|
|
Transmission power |
Max. 2 W |
|
|
|
|
|
|
Pollution degree |
Residential (pollution degree 2) |
|
|
|
|
|
|
Software classification |
A |
|
|
|
|
|
|
IP class |
20 |
|
|
|
|
|
|
Dimensions (l x h x d) |
87.5 mm x 90 mm x 40 mm |
|
|
|
|
|
|
Weight |
0.136 kg |
|
Technical Specifications |
|
|
|
|
|
|
|
Type |
Specifications |
|
|
for Danfoss LinkTM HC |
Supply voltage |
230 V AC |
|
|
Number of outputs and voltage |
10/24 V DC |
|
|
|
|
|
|
Ambient temperature |
0 to +50 °C |
|
|
|
|
|
|
Transport temperature |
0 to +50 °C |
|
|
|
|
|
|
Transmission frequency |
868.42 MHz |
|
|
|
|
|
|
Transmission range (up to) |
30 m (in normal buildings) |
|
|
|
|
|
|
Transmission power |
Max. 1 mW |
|
|
|
|
|
|
Max. running load of actuator output |
35 VA in total for all outputs |
|
|
|
|
|
|
Max. load for pump relay |
230 V and 8 A / 2 A (inductive) |
|
|
|
|
|
2 |
VDFZG102 |
© Danfoss |
12/2012 |
Danfoss Heating Solutions |