Danfoss LE20-CPC Technical Information

Logic Elements Technical Information
US gal/min
100
120
140
160
OPERATION
The LE20-CPC is a 20-size, normally-closed, pilot-to-close, spool-type,, spring biased dierential-sensing logic element. It will modulate ow from 1 to 2 based on the spring control pressure, inlet pressure at port 1, and pilot pressure at port 3.
APPLICATION
Common applications include load-sensing bypass compensator for a xed displacement pump with single or multiple actuators as well as bypass-type pressure-compensated ow control. Eective use of logic elements is a key to designing cost-eective circuits, and is limited only by the imagination of the designer.
SPECIFICATION
Rated pressure 210 bar [3045 psi]
Rated ow at 7 bar
[100 psi]
340 l/min
[90 US gal/min]
Weight 1.19 kg [2.62 lb]
Cavity CP20-3S
PERFORMANCE CURVE
Theoretical performance
bar
psi
10
8
6
80
60
4
40
2
20
0
0
0
BC332375783111en-000101 • February 2020
3
Pressure drop 33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
1
2
FULLY OPENED
80
20
160
40 80
320
240
60 100
SCHEMATIC
2
1
Flow
400
L/min
LE - 27
Logic Elements Technical Information
Spool Type
LE20-CPC
DIMENSION
mm [in]
1
EXAMPLE CIRCUITS
79.30
[3.12]
Cross-sectional view
1.875 in.
1-5/8-12 UN
217-231 Nm [160-170 lbf-ft]
2
3
56.62
[2.23]
LE20-CPC
Double Acng Cylinder with Proporonal Speed
Control, Unloading Valve and Circuit Relief
ORDERING INFORMATION
LE20-CPC-5.5-B-00
Logic Element, 20 Size Cavity
Normally Closed, Pilot-to-Close
Differential Control Pressure
5.5 = 5.5 bar [80 psi]
7.0 = 7 bar [100 psi]
10.0 = 10.0 bar [150 psi]
15.0 = 15.0 bar [218 psi]
BC332375783111en-000101 • February 2020
Proporonal Bypass Flow Control
Housing and ports 00 = No Housing 8B = Al, 1 BSP 10B = Al, 1-1/4 BSP 16S = Al, #16 SAE 20S = Al, #20 SAE
Seals Seal Kit B = Buna-N 120380 V = Viton 120381
Dump and Relief Valve for a Fixed Pump
Housing Part # No Housing CP20-3S-8B/2B CP20-3S-10B/2B CP20-3S-16S/4S CP20-3S-20S/4S
Pilot Port
1/4 BSP 1/4 BSP #4 SAE #4 SAE
LE - 28