Installation Guide

Damping orifice for

ICS 25-80 and ICLX 32-80

<![if ! IE]>

<![endif]>027R9620

<![if ! IE]>

<![endif]>027R9620

ENGLISH

Damping orifice for ICS /ICLX

If an external pilot connection is used in series with an EVM solenoid valve in ICS 2580, the following applies: If the external control pressure, e.g. with hot gas, is more than 6 bar higher than the inlet pressure of the main valve, the damping orifice must be fitted in the EVM, as shown on

the drawing.

Note! The damping orifice must always be fitted in ICLX 32-80 as shown on the drawing.

DANSK

Dæmpedyse til ICS / ICLX

Anvendes ekstern pilottilslutning i serie med en EVM magnetpilotventil i ICS 25-80, gælder følgende:

Hvis det eksterne styretryk, f.eks. med varm-gas, er mere end 6 bar højere end hovedventilens tilgangstryk, skal dæmpedysen monteres i EVM som vist på tegningen.

NB! Dæmpedysen skal altid monteres i ICLX 32-80 som vist på tegningen.