Danfoss FH-ME Installation guide

Danfoss FH-ME Installation guide

Instruction

FH-ME manifold

FH-ME

Capacity

kVS

p

p

p

 

 

[mwg]

[bar]

[kPa]

 

 

Q [l/h]

t = 5 ˚C

kW

t = 10 ˚C

kW

Danfoss Heating Solutions

VIUDR12P

05/2012

1

Instruction

FH-ME manifold

 

 

FH-ME

 

 

 

FH-ME Installation instruction

FH-ME

1. The manifold integrated with control valve (with red

1.

plastic protection cap) must be installed as return pipe,

 

the manifold integrated shut off valve insert (with round

 

red plastic cover) must be installed as flow pipe.

 

2. The end piece and pipe connectors connected to

2.

manifold should be 1” round thread and sealed by

1

rubber sealing material at the end, the length of thread

14mm

inserted into the manifold should be less than 14mm.

 

3. The valves in both flow and return manifold should be

3.

fully opened during pressure test.

 

Technical Data

 

 

 

 

 

 

 

 

Test pressure

16 bar

 

 

16 bar

Max. working pressure

10 bar

 

 

 

 

 

 

 

10 bar

 

 

 

Max. differential pressure

0.6 bar

 

 

 

 

 

 

 

 

0.6 bar

 

 

 

Max. flow temperature

90°C

 

 

 

 

 

 

 

 

90°C

 

 

 

Max. ambient temperature,

 

 

60°C

 

 

TWA actuator

 

TWA

60°C

 

 

Note: Maximum operating pressure and temperature given by the

 

 

 

 

 

 

 

tube manufacturer must not be exceeded.

 

 

 

 

 

900 C 20

 

200233

 

+86 21 61513000

 

+86 21 61513100

 

 

 

2 A 20

 

100027

 

+86 10 85352588

Danfoss A/S

+86 10 85352599

 

Heating Solutions

 

Haarupvaenget 11

358 10

8600 Silkeborg

300100

Denmark

+86 22 27505888

Phone:+45 7488 8000

+86 22 27505999

 

Fax: +45 7488 8100

http://www.danfoss.com.cn

Email: heating.solutions@danfoss.com

http://heating.danfoss.com

www.heating.danfoss.com

http://cn.heating.danfoss.com

 

 

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed

Danfoss Danfoss

material. Danfoss reserves the right to alter its products without notice. This also applies to prod-

 

ucts already on order provided that such alterations can be made without subsequential changes

Danfoss Danfoss

being necessary in specifications already agreed.

Danfoss A/S

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss

 

logotype are trademarks of Danfoss A/S. All rights reserved.

 

013R9560 & VIUDR12P

Produced by Danfoss A/S © 05/2012

 

Loading...